International Multicenter Trial on Clinical Natural Orifice Surgery—NOTES IMTN Study: Preliminary Results of 362 Patients

2010 ◽  
Vol 17 (2) ◽  
pp. 142-158 ◽  
Author(s):  
Ricardo Zorron ◽  
Chinnusamy Palanivelu ◽  
Manoel Passos Galvão Neto ◽  
Almino Ramos ◽  
Gustavo Salinas ◽  
...  
1998 ◽  
Vol 44 (12) ◽  
pp. 2530-2536 ◽  
Author(s):  
Huub E van Ingen ◽  
Daniel W Chan ◽  
Walter Hubl ◽  
Hayato Miyachi ◽  
Rafael Molina ◽  
...  

Abstract The CA 125 II assay on the Elecsys® 2010 analyzer was evaluated in an international multicenter trial. Imprecision studies yielded within-run CVs of 0.8–3.3% and between-day CVs of 2.4–10.9%; CVs for total imprecision in the manufacturer’s laboratory were 2.4–7.8%. The linear range of the assay extended to at least 4500 kilounits/L (three decades). Interference from triglycerides (10.3 mmol/L), bilirubin (850 μmol/L), hemoglobin (1.1 mmol/L), anticoagulants (plasma), and several widely used drugs was undetectable. Method comparisons with five other CA 125 II assays showed good correlation but differences in standardization. A 95th percentile cutoff value of 35 kilounits/L was calculated from values measured in 593 apparently healthy (pre- and postmenopausal) women. In 95% of patients with benign gynecological diseases CA 125 was ≤190 kilounits/L; 63% of patients with newly diagnosed ovarian carcinoma had values >190 kilounits/L. A comparison of CA 125 values obtained with the Elecsys test and with other common CA 125 tests in monitored patients being treated for ovarian cancer showed identical patterns. In conclusion, the Elecsys CA 125 II assay is linear over a broad range, yields precise and accurate results, is free from interferences, and compares well with other assays.


2021 ◽  
Vol 12 ◽  
Author(s):  
Albert J. Yoo ◽  
Jazba Soomro ◽  
Tommy Andersson ◽  
Jeffrey L. Saver ◽  
Marc Ribo ◽  
...  

Background and Purpose: End-of-procedure substantial reperfusion [modified Treatment in Cerebral Ischemia (mTICI) 2b-3], the leading endpoint for thrombectomy studies, has several limitations including a ceiling effect, with recent achieved rates of ~90%. We aimed to identify a more optimal definition of angiographic success along two dimensions: (1) the extent of tissue reperfusion, and (2) the speed of revascularization.Methods: Core-lab adjudicated TICI scores for the first three passes of EmboTrap and the final all-procedures result were analyzed in the ARISE II multicenter study. The clinical impact of extent of reperfusion and speed of reperfusion (first-pass vs. later-pass) were evaluated. Clinical outcomes included 90-day functional independence [modified Rankin Scale (mRS) 0–2], 90-day freedom-from-disability (mRS 0–1), and dramatic early improvement [24-h National Institutes of Health Stroke Scale (NIHSS) improvement ≥ 8 points].Results: Among 161 ARISE II subjects with ICA or MCA M1 occlusions, reperfusion results at procedure end showed substantial reperfusion in 149 (92.5%), excellent reperfusion in 121 (75.2%), and complete reperfusion in 79 (49.1%). Reperfusion rates on first pass were substantial in 81 (50.3%), excellent reperfusion in 62 (38.5%), and complete reperfusion in 44 (27.3%). First-pass excellent reperfusion (first-pass TICI 2c-3) had the greatest nominal predictive value for 90-day mRS 0–2 (sensitivity 58.5%, specificity 68.6%). There was a progressive worsening of outcomes with each additional pass required to achieve TICI 2c-3.Conclusions: First-pass excellent reperfusion (TICI 2c-3), reflecting rapid achievement of extensive reperfusion, is the technical revascularization endpoint that best predicted functional independence in this international multicenter trial and is an attractive candidate for a lead angiographic endpoint for future trials.Clinical Trial Registration:http://www.clinicaltrials.gov, identifier NCT02488915.


Sign in / Sign up

Export Citation Format

Share Document