scholarly journals Optimization of the Reconstruction Interval in Neurovascular 4D-CTA Imaging

2012 ◽  
Vol 18 (4) ◽  
pp. 377-379 ◽  
Author(s):  
T.C.H. Hoogenboom ◽  
R.M.J. Van Beurden ◽  
B. Van Teylingen ◽  
B. Schenk ◽  
P.W.A. Willems

Time resolved whole brain CT angiography (4D-CTA) is a novel imaging technology providing information regarding blood flow. One of the factors that influence the diagnostic value of this examination is the temporal resolution, which is affected by the gantry rotation speed during acquisition and the reconstruction interval during post-processing. Post-processing determines the time spacing between two reconstructed volumes and, unlike rotation speed, does not affect radiation burden. The data sets of six patients who underwent a cranial 4D-CTA were used for this study. Raw data was acquired using a 320-slice scanner with a rotation speed of 2 Hz. The arterial to venous passage of an intravenous contrast bolus was captured during a 15 s continuous scan. The raw data was reconstructed using four different reconstruction-intervals: 0.2, 0.3, 0.5 and 1.0 s. The results were rated by two observers using a standardized score sheet. The appearance of each lesion was rated correctly in all readings. Scoring for quality of temporal resolution revealed a stepwise improvement from the 1.0 s interval to the 0.3 s interval, while no discernable improvement was noted between the 0.3 s and 0.2 s interval. An increase in temporal resolution may improve the diagnostic quality of cranial 4D-CTA. Using a rotation speed of 0.5 s, the optimal reconstruction interval appears to be 0.3 s, beyond which, changes can no longer be discerned.

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Abhik Datta ◽  
Kian Fong Ng ◽  
Deepan Balakrishnan ◽  
Melissa Ding ◽  
See Wee Chee ◽  
...  

AbstractFast, direct electron detectors have significantly improved the spatio-temporal resolution of electron microscopy movies. Preserving both spatial and temporal resolution in extended observations, however, requires storing prohibitively large amounts of data. Here, we describe an efficient and flexible data reduction and compression scheme (ReCoDe) that retains both spatial and temporal resolution by preserving individual electron events. Running ReCoDe on a workstation we demonstrate on-the-fly reduction and compression of raw data streaming off a detector at 3 GB/s, for hours of uninterrupted data collection. The output was 100-fold smaller than the raw data and saved directly onto network-attached storage drives over a 10 GbE connection. We discuss calibration techniques that support electron detection and counting (e.g., estimate electron backscattering rates, false positive rates, and data compressibility), and novel data analysis methods enabled by ReCoDe (e.g., recalibration of data post acquisition, and accurate estimation of coincidence loss).


Author(s):  
O. Sumner ◽  
R. Goldsmith ◽  
N. Heath ◽  
G. D. Taylor

Abstract Purpose Preformed metal crowns are widely used to restore primary and permanent teeth. Children may require magnetic resonance imaging (MRI) for diagnosis and monitoring of diseases in the head and neck region. Metallic objects, in the field of view, may compromise the diagnostic value of an MRI. The impact on the diagnostic quality of an MRI in children who have had preformed metal crowns placed has not been assessed. The aim of this systematic review was to evaluate the impact that PFMCs have on MRI imaging quality and thus the overall diagnostic value. Methods Electronic searches of the following databases were completed: MEDLINE, EMBASE, Cochrane Library, Web of Science and Open Grey. Primary in vivo studies on children who had at least one preformed metal crown placed and required an MRI investigation were to be included. PRISMA guidelines were followed and screening/data extraction was carried out by two independent calibrated reviewers. Results A total of 7665 articles were identified. After removing duplicates, 7062 were identified for title and abstract screening. Thirty-four articles underwent full-text review, of which none met the inclusion criteria. Most common reasons for exclusion were not placing preformed metal crowns (n = 16) or in vitro studies (n = 12). Conclusion No in vivo studies were identified to establish the hypothetical impact preformed metal crowns would have on the diagnostic quality of an MRI in the head and neck region. Decision making needs to be guided on a case by case basis. Further high-quality clinical studies are required.


2020 ◽  
Vol 26 (4) ◽  
Author(s):  
Allan Gomes ◽  
Claudia Pereira Krueger

Abstract: Since the introduction of the Android 7 in August 2016, it has become possible to use raw data collected by GNSS sensors present in some Android smartphones and tablets. Therefore, it became possible, for the first time, to perform the post-processing of the data, which means to obtain coordinates that are more accurate than usual, from meters to decimeters. In addition, among the technological innovations in the context of positioning via smartphones, it is mentioned the use of modern GNSS sensors, like the one used by Xiaomi Mi 8, which was the first smartphone to integrate a dual-frequency GNSS sensor. In this research, data collection campaigns were carried out in static mode to evaluate the quality of geodetic coordinates obtained from Mi 8. Using freely available applications that store raw data in files in RINEX format, the data was post-processed with different positioning methods and with different software, including the freely available IBGE-PPP online service in Brazil. The results of this research show that it is possible to obtain geodetic coordinates with an accuracy at decimeter order, which indicates that the methodology can be used in some engineering applications.


2019 ◽  
Vol 1 (1) ◽  
pp. 16-18 ◽  
Author(s):  
Norafida Bahari ◽  
Nik Azuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.


Author(s):  
Norafida Bahari ◽  
NikAzuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.


2014 ◽  
Vol 56 (5) ◽  
pp. 381-385
Author(s):  
Ayhan Orhan ◽  
Yücel Asma
Keyword(s):  

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Lei Xi ◽  
Chunqing Yang

AbstractObjectivesThe main aim of the present study was to assess the diagnostic value of alpha-l-fucosidase (AFU) for hepatocellular carcinoma (HCC).MethodsStudies that explored the diagnostic value of AFU in HCC were searched in EMBASE, SCI, and PUBMED. The sensitivity, specificity, and DOR about the accuracy of serum AFU in the diagnosis of HCC were pooled. The methodological quality of each article was evaluated with QUADAS-2 (quality assessment for studies of diagnostic accuracy 2). Receiver operating characteristic curves (ROC) analysis was performed. Statistical analysis was conducted by using Review Manager 5 and Open Meta-analyst.ResultsEighteen studies were selected in this study. The pooled estimates for AFU vs. α-fetoprotein (AFP) in the diagnosis of HCC in 18 studies were as follows: sensitivity of 0.7352 (0.6827, 0.7818) vs. 0.7501 (0.6725, 0.8144), and specificity of 0.7681 (0.6946, 0.8283) vs. 0.8208 (0.7586, 0.8697), diagnostic odds ratio (DOR) of 7.974(5.302, 11.993) vs. 13.401 (8.359, 21.483), area under the curve (AUC) of 0.7968 vs. 0.8451, respectively.ConclusionsAFU is comparable to AFP for the diagnosis of HCC.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
C. Callenberg ◽  
A. Lyons ◽  
D. den Brok ◽  
A. Fatima ◽  
A. Turpin ◽  
...  

AbstractImaging across both the full transverse spatial and temporal dimensions of a scene with high precision in all three coordinates is key to applications ranging from LIDAR to fluorescence lifetime imaging. However, compromises that sacrifice, for example, spatial resolution at the expense of temporal resolution are often required, in particular when the full 3-dimensional data cube is required in short acquisition times. We introduce a sensor fusion approach that combines data having low-spatial resolution but high temporal precision gathered with a single-photon-avalanche-diode (SPAD) array with data that has high spatial but no temporal resolution, such as that acquired with a standard CMOS camera. Our method, based on blurring the image on the SPAD array and computational sensor fusion, reconstructs time-resolved images at significantly higher spatial resolution than the SPAD input, upsampling numerical data by a factor $$12 \times 12$$ 12 × 12 , and demonstrating up to $$4 \times 4$$ 4 × 4 upsampling of experimental data. We demonstrate the technique for both LIDAR applications and FLIM of fluorescent cancer cells. This technique paves the way to high spatial resolution SPAD imaging or, equivalently, FLIM imaging with conventional microscopes at frame rates accelerated by more than an order of magnitude.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Francesco Giganti ◽  
Alex Kirkham ◽  
Veeru Kasivisvanathan ◽  
Marianthi-Vasiliki Papoutsaki ◽  
Shonit Punwani ◽  
...  

AbstractProstate magnetic resonance imaging (MRI) of high diagnostic quality is a key determinant for either detection or exclusion of prostate cancer. Adequate high spatial resolution on T2-weighted imaging, good diffusion-weighted imaging and dynamic contrast-enhanced sequences of high signal-to-noise ratio are the prerequisite for a high-quality MRI study of the prostate. The Prostate Imaging Quality (PI-QUAL) score was created to assess the diagnostic quality of a scan against a set of objective criteria as per Prostate Imaging-Reporting and Data System recommendations, together with criteria obtained from the image. The PI-QUAL score is a 1-to-5 scale where a score of 1 indicates that all MR sequences (T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced sequences) are below the minimum standard of diagnostic quality, a score of 3 means that the scan is of sufficient diagnostic quality, and a score of 5 implies that all three sequences are of optimal diagnostic quality. The purpose of this educational review is to provide a practical guide to assess the quality of prostate MRI using PI-QUAL and to familiarise the radiologist and all those involved in prostate MRI with this scoring system. A variety of images are also presented to demonstrate the difference between suboptimal and good prostate MR scans.