A comparative numerical study to compute ocular injury in boxing

Author(s):  
Reza Razaghi ◽  
Hasan Biglari

Sport is responsible for between 25% and 40% of all eye injuries. Trauma is integrated to the nature of the sport, especially boxing, which is considered a high-risk sport for ocular injuries. Boxing not only brings about injury to the external side of the eye, but in nearly one third of cases, the intraocular components of the eye are also damaged, followed by serious visual acuity complications. However, so far there is a paucity of knowledge on the ocular injury as a result of a strong hook to the face during boxing. This study was, therefore, aimed to perform a dynamic finite element simulation to calculate the stresses and deformations to the components of the eye (i.e. the cornea, aqueous body, iris, ciliary body, vitreous body, sclera, retina, and optic nerve) as a consequence of a hook to the zygomatic and frontal skull bones of a boxer. To do that, well-verified finite element models of the human skull, eye, and punch developed by the current authors were employed to simulate the traumatic model of the skull. The resulting von Mises stresses and deformations in each component of the eye were calculated and compared. The results revealed higher stresses in the components of the eye as a result of a frontal impact compared to that of the zygomatic one. The concentration of the von Mises stresses in the eye components was mostly located in the lateral circumference of the globe. Regardless of the impact sites, the muscle experienced severe damage while the cornea, as the most anterior, and optic nerve, as the most posterior components of the eye, stayed safe with trivial amounts of stress and deformation. These results have implications not only for understanding the possible ocular injuries from a hook but also for providing comprehensive information to medical experts regarding the types of ocular injuries which may occur during boxing.

2021 ◽  
Vol 3 (3) ◽  
pp. 33-37
Author(s):  
Jairo Aparecido Martins ◽  
Estaner Claro Romão

This paper presents an investigation of changes on design and material of a Howe bridge under vertical loads. Specifically, it aimed to find out how small changes on Howe bridge design and material affected von Mises stresses as well as stresses at Z direction. As a method, it was used a finite element analysis (linear-elastic) by Autodesk F-360. Half of a bridge was designed (one bridge side) and loaded with a central higher load and two equal smaller lateral loads. In essence, von Mises stresses (s) and stress at Z direction (sz) decreased on stresses values until a certain design change, which was proportional to a raise of mass due to beams added on the trusses. With a change of material to a lighter metal, from steel to aluminum, it was possible to overcome the mass drawback brought by steel and utterly possible to end up for a more effective design for a Howe truss bridge by applying minimal design changes.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Jun Fu ◽  
Ming Ni ◽  
Jiying Chen ◽  
Xiang Li ◽  
Wei Chai ◽  
...  

Purpose. The purpose of this study was to establish the finite element analysis (FEA) model of acetabular bone defect reconstructed by 3D printed Ti6Al4V augment and TM augment and further to analyze the stress distribution and clinical safety of augments, screws, and bones.Methods. The FEA model of acetabular bone defect reconstructed by 3D printed Ti6Al4V augment was established by the CT data of a patient with Paprosky IIIA defect. The von Mises stresses of augments, screws, and bones were analyzed by a single-legged stance loading applied in 3 increments (500 N, 2000 N, and 3000 N).Results. The peak von Mises stresses under the maximal loading in the 3D printed augments, screws, and cortical bone were less than the yield strength of the corresponding component. However, the peak stress in the bone was greater than the yield strength of cancellous bone under walking or jogging loading. And under the same loading, the peak compressive and shear stresses in bone contact with TM augment were larger than these with 3D printed augment.Conclusions. The FEA results show that all the components will be intact under single-legged standing. However, partial cancellous bone contacted with 3D printed augment and screws will lose efficacy under walking or jogging load. So we recommend that patients can stand under full bearing, but can not walk or jog immediately after surgery.


1994 ◽  
Vol 116 (4) ◽  
pp. 401-407 ◽  
Author(s):  
J. Chen ◽  
Liangfeng Xu

A 2-D finite element model of the human temporomandibular joint (TMJ) has been developed to investigate the stresses and reaction forces within the joint during normal sagittal jaw closure. The mechanical parameters analyzed were maximum principal and von Mises stresses in the disk, the contact stresses on the condylar and temporal surfaces, and the condylar reactions. The model bypassed the complexity of estimating muscle forces by using measured joint motion as input. The model was evaluated by several tests. The results demonstrated that the resultant condylar reaction force was directed toward the posterior side of the eminence. The contact stresses along the condylar and temporal surfaces were not evenly distributed. Separations were found at both upper and lower boundaries. High tensile stresses were found at the upper boundaries. High tensile stresses were found at the upper boundary of the middle portion of the disk.


2014 ◽  
Vol 60 (3) ◽  
pp. 323-334 ◽  
Author(s):  
G. Leonardi

Abstract The paper presents a numerical study of an aircraft wheel impacting on a flexible landing surface. The proposed 3D model simulates the behaviour of flexible runway pavement during the landing phase. This model was implemented in a finite element code in order to investigate the impact of repeated cycles of loads on pavement response. In the model, a multi-layer pavement structure was considered. In addition, the asphalt layer (HMA) was assumed to follow a viscoelastoplastic behaviour. The results demonstrate the capability of the model in predicting the permanent deformation distribution in the asphalt layer.


2018 ◽  
Vol 90 (4) ◽  
pp. 652-658
Author(s):  
Péter Deák

Purpose The purpose of this paper is to make an analytical comparison of two vertical tail models from a structural point of view. Design/methodology/approach The original vertical tail design of PZL-106BT aircraft was used for Computer aided design (CAD) modeling and for creating the finite element model. Findings The nodal displacements, Von-Mises stresses and Buckling factors for two vertical tail models have been found using the finite element method. The idea of a possible Multidisciplinary concept assessment and design (MDCAD) concept was presented. Practical implications The used software analogy introduces an idea of having an automated calculation procedure within the framework of MDCAD. Originality/value The aircraft used for calculation had undergone a modification in its vertical tail length, as there was an urgent need to calculate for the plane’s manufacturer, PZL Warszawa – Okecie.


Author(s):  
Huaidong Yang ◽  
Itzhak Green

This work presents a finite element study of a 2D plane strain fretting model of a half-cylinder in contact with a flat block under oscillatory tangential loading. The two bodies are deformable and are set to Inconel 617 and Incoloy 800H at room temperature (20 ℃) and 800 ℃. However, because the results are normalized, they can characterize a range of contact scales (micro to macro). Different coefficients of friction are used at the interface. This work finds that the edges of the contacting areas experience large von Mises stresses along with significant residual plastic strains, while pileup could also appear when the coefficients of friction are sufficiently large. In addition, junction growth is investigated, showing that the direction of the growth is in the same direction of the tangential force that the weaker material (Incoloy alloy 800H) experiences. The fretting loop (caused by the tangential force during the fretting motion) for the initial few cycles of loading is generated, and it compares well with the reported experimental results. The different extents of damage at room temperature and 800 ℃ are also compared.


Author(s):  
Alireza Karimi ◽  
Reza Razaghi ◽  
Ahmad Shojaei ◽  
Mahdi Navidbakhsh

AbstractThe stresses induced within plaque tissues and arterial layers during stent expansion inside an atherosclerotic artery can be exceeded from the yield stresses of those tissues and, consequently, lead to plaque or arterial wall rupture. The distribution and magnitude of the stresses in the plaque-artery-stent structure might be distinctly different for different plaque types. In this study, the mechanical properties of six healthy and atherosclerotic human coronary arteries were determined for application in plaque and arterial vulnerability assessment. A nonlinear finite element simulation based on an Ogden material model was established to investigate the effect of plaque types on the stresses induced in the arterial wall during implantation of a balloon expandable coronary stent. The atherosclerotic artery was assumed to consist of a plaque and normal arterial tissues on its outer side. The results indicated a significant influence of plaque types on the maximum stresses induced within the plaque wall and arterial wall during stenting but not when computing maximum stress on the stent. The stress on the stiffest calcified plaque wall was 3.161 MPa, whereas cellular and hypocellular plaques showed relatively less stress on their wall. The highest von Mises stresses within the arterial wall were observed on the hypocellular plaque, whereas the lowest stresses were seen to be located in the calcified and cellular plaques. Although the computed stresses on the arterial wall for the calcified and cellular plaques were not high enough to invoke a rupture, the stress on the hypocellular plaque was relatively higher than that of the strength of the arterial wall. These findings may have implications not only for understanding the stresses induced in plaque and the arterial wall, but also for developing surgeries such as balloon-angioplasty and stenting.


2014 ◽  
Vol 658 ◽  
pp. 201-206
Author(s):  
Catalin Pirvu ◽  
Simona Badea ◽  
Lorena Deleanu

This paper presents a simulation of a bullet impact on a plate made of a homogeneous and isotropic material. The developed model takes into account the yield and fracture limits of both involved materials for the bullet and the plate one. The model was developed with the help of Ansys 14.0 and could be used to establish a theoretical value of the plate thickness that will offer protection to the bullet penetration in order to minimize the number of laboratory tests for evaluating the plate resistance. The authors presented the influence of impact velocity of the bullet. The bullet velocity just reaching the plate is an essential parameter influencing the plate integrity. Also, the authors established a correlation between the evolution of the theoretical maximum von Mises stresses and the stages taking place during the impact.


2015 ◽  
Vol 6;18 (6;11) ◽  
pp. E1101-E1110
Author(s):  
Ah-Reum Cho

Background: Vertebroplasty is an effective treatment for osteoporotic vertebral fractures, which are one of the most common fractures associated with osteoporosis. However, clinical observation has shown that the risk of adjacent vertebral body fractures may increase after vertebroplasty. The mechanism underlying adjacent vertebral body fracture after vertebroplasty is not clear; excessive stiffness resulting from polymethyl methacrylate has been suspected as an important mechanism. Objectives: The aim of our study was to compare the effects of bone cement stiffness on adjacent vertebrae after osteoporotic vertebroplasty under load-controlled versus displacementcontrolled conditions. Study Design: An experimental computer study using a finite element analysis. Setting: Medical research institute, university hospital, Korea. Methods: A three-dimensional digital anatomic model of L1/2 bone structure was reconstructed from human computed tomographic images. The reconstructed three-dimensional geometry was processed for finite element analysis such as meshing elements and applying material properties. Two boundary conditions, load-controlled and displacement-controlled methods, were applied to each of 5 deformation modes: compression, flexion, extension, lateral bending, and torsion. Results: The adjacent L1 vertebra, irrespective of augmentation, revealed nearly similar maximum von Mises stresses under the load-controlled condition. However, for the displacementcontrolled condition, the maximum von Mises stresses in the cortical bone and inferior endplate of the adjacent L1 vertebra increased significantly after cement augmentation. This increase was more significant than that with stiffer bone cement under all modes, except the torsion mode. Limitations: The finite element model was simplified, excluding muscular forces and incorporating a large volume of bone cement, to more clearly demonstrate effects of bone cement stiffness on adjacent vertebrae after vertebroplasty. Conclusion: Excessive stiffness of augmented bone cement increases the risk of adjacent vertebral fractures after vertebroplasty in an osteoporotic finite element model. This result was most prominently observed using the displacement-controlled method. Key words: Bone cements, displacement-controlled method, finite element analysis, loadcontrolled method, osteoporosis, osteoporotic fracture, polymethyl methacrylate, vertebroplasty


Sign in / Sign up

Export Citation Format

Share Document