scholarly journals Dependence of image quality of LGE-MRI of the left atrium on the acceptance rate of respiratory navigator and acquisition time

2013 ◽  
Vol 15 (S1) ◽  
Author(s):  
Sathya Vijayakumar ◽  
Chankevin Tek ◽  
Nathan S Burgon ◽  
Christopher McGann ◽  
Nassir F Marrouche ◽  
...  
Author(s):  
Heiner Nebelung ◽  
Thomas Brauer ◽  
Danilo Seppelt ◽  
Ralf-Thorsten Hoffmann ◽  
Ivan Platzek

Abstract Objectives The aim of the study was to evaluate the effect of bolus-tracking ROI positioning on coronary computed tomography angiography (CCTA) image quality. Methods In this retrospective monocentric study, all patients had undergone CCTA by step-and-shoot mode to rule out coronary artery disease within a cohort at intermediate risk. Two groups were formed, depending on ROI positioning (left atrium (LA) or ascending aorta (AA)). Each group contained 96 patients. To select pairs of patients, propensity score matching was used. Image quality with regard to coronary arteries as well as pulmonary arteries was evaluated using quantitative and qualitative scores. Results In terms of the coronary arteries, there was no significant difference between both groups using quantitative (SNR AA 14.92 vs. 15.46; p = 0.619 | SNR LM 19.80 vs. 20.30; p = 0.661 | SNR RCA 24.34 vs. 24.30; p = 0.767) or qualitative scores (4.25 vs. 4.29; p = 0.672), respectively. With regard to pulmonary arteries, we found significantly higher quantitative (SNR RPA 8.70 vs. 5.89; p < 0.001 | SNR LPA 9.06 vs. 6.25; p < 0.001) and qualitative scores (3.97 vs. 2.24; p < 0.001) for ROI positioning in the LA than for ROI positioning in the AA. Conclusions ROI positioning in the LA or the AA results in comparable image quality of CT coronary arteriography, while positioning in the LA leads to significantly higher image quality of the pulmonary arteries. These results support ROI positioning in the LA, which also facilitates triple-rule-out CT scanning. Key Points • ROI positioning in the left atrium or the ascending aorta leads to comparable image quality of the coronary arteries. • ROI positioning in the left atrium results in significantly higher image quality of the pulmonary arteries. • ROI positioning in the left atrium is feasible to perform triple-rule-out CTA.


2020 ◽  
Vol 30 (5) ◽  
pp. 2712-2721 ◽  
Author(s):  
Waleed Abdellatif ◽  
Eric Esslinger ◽  
Kevin Kobes ◽  
Amanda Wong ◽  
Jennifer Powell ◽  
...  

Herz ◽  
2022 ◽  
Author(s):  
Uzair Ansari ◽  
Sonja Janssen ◽  
Stefan Baumann ◽  
Martin Borggrefe ◽  
Stephan Waldeck ◽  
...  

Abstract Background We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. Methods A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen’s kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). Results Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen’s kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, p < 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, p = n.s.). The mean acquisition time for the study sequence was 553 s (±46 s). Conclusion Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.


2018 ◽  
Vol 4 (Supplement 2) ◽  
pp. 68s-68s
Author(s):  
B. Ali ◽  
A. Afshan ◽  
M.B. Kakakhel

Background: In PET imaging both quantitative and qualitative interpretations are used. Qualitative and quantitative interpretations depend upon PET/CT image quality that along with many biologic factors strongly depends upon image reconstruction parameters. Aim: The objective of this experimental work was to study the impact of one of the key reconstruction parameter, i.e., number of reconstruction iteration, on standardized uptake value and image quality of PET/CT scan. Methods: Images of NEMA IEC Image Quality Phantom were acquired in list mode for 10 mins on Discovery STE PET/CT scanner, using tumor to background ratio of 4:1 and 18F-FDG as radiotracer. List mode data were further transformed into data sets of varying acquisition time (0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mins) per bed position. Transformed data set of 5.0 mins were used to study the impact of varying number of iterations (2, 3, 4, 5, 7, 10, 15, 20) using OSEM approach of iterative reconstruction. Standardized uptake value (SUV) and underestimation in SUV were calculated as quantitative measures, while hot lesion contrast, cold lesion contrast and background variability were calculated as qualitative measures. Results: Standardized uptake value, hot and cold lesion contrast, image spatial resolution and background variability showed increasing trend with increase in reconstruction iterations. Maximum increase of 20.25%, 16.33%, 9.79% and 6.88% was observed in SUV for 10 mm, 13 mm, 17 mm and 22 mm lesions as number of iteration change from 2 to 3. Smallest and the largest diameter lesions showed maximum underestimations of 54.67% and 8.20% at 2 iterations respectively. Percentage hot lesion contrast showed rapid increase as the number of iteration change from 2 to 7 and increased slowly afterward. Background variability range from 4.4% to 6.4%, 4.1%–5.7%, 3.6%–4.6%, 3%–3.8%, 2.7%–3.2%, 2.4%–2.7% for 10.0 mm, 13.0 mm, 17.0 mm, 22.0 mm, 28.0 mm and 37.0 mm sphere respectively. Conclusion: Optimized reconstruction parameters for routine clinical studies 3 iterations with image matrix size of 128 × 128 with filters FWHM of 6 mm and for high resolution studies 3 iterations image matrix size of 256×256 with filters FWHM of 6 mm.


2021 ◽  
Author(s):  
Yanhua Duan ◽  
Minjie Zhao ◽  
Keyu Zan ◽  
Ying Wang ◽  
Xiao Cui ◽  
...  

Abstract PurposeThe study is to evaluate the diagnostic performance and image quality of a 20-second breath-hold (BH) 18F-FDG total-body PET acquisition compared with a free-breathing (FB) PET for stage IA pulmonary adenocarcinoma.Materials and MethodsForty-seven patients with confirmed stage IA pulmonary adenocarcinoma were enrolled. All patients underwent total-body 18F–FDG PET/CT and the acquisition time was 300 s, followed by a 20-s BH PET. A 20-s FB PET was extracted from the 300-s PET. The size and volume of lesions were measured on BHCT images. The SUVmax, tumor-to-background ratio (TBR), metabolic tumor volume (MTV), %ΔSUVmax and %ΔTBR of the lesions were measured and recorded. The lesions were further divided by distance from pleura, lesion size, and morphological characteristic for subgroup analysis. ResultsIn the cohort and subgroup analysis, the SUVmax and TBR were significantly increased with 20-BH PET compared with 300-FB PET and 20-FB PET (all p<0.05). And the %ΔSUVmax and %ΔTBR in D1 groups (≤10 mm in distance) higher than those in D2 and D3 groups (>10 mm). The diagnostic performance of BH PET was significantly higher than that of FB PET (all p<0.001). The Bland-Altman plot for agreement on lesion’s volume between BH PET and CT showed good agreement than FB PET.ConclusionThe 20-s BH PET acquisition is more sensitive to quantitative and qualitative analysis for stage IA pulmonary adenocarcinoma. 20-s BH PET/CT acquisition reduces the blurring effect of respiratory motion especially for subpleural nodules (≤10 mm in distance).


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
John Ly ◽  
David Minarik ◽  
Jonas Jögi ◽  
Per Wollmer ◽  
Elin Trägårdh

Abstract Background The aim of the study was to develop and test an artificial intelligence (AI)-based method to improve the quality of [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET) images. Methods A convolutional neural network (CNN) was trained by using pairs of excellent (acquisition time of 6 min/bed position) and standard (acquisition time of 1.5 min/bed position) or sub-standard (acquisition time of 1 min/bed position) images from 72 patients. A test group of 25 patients was used to validate the CNN qualitatively and quantitatively with 5 different image sets per patient: 4 min/bed position, 1.5 min/bed position with and without CNN, and 1 min/bed position with and without CNN. Results Difference in hotspot maximum or peak standardized uptake value between the standard 1.5 min and 1.5 min CNN images fell short of significance. Coefficient of variation, the noise level, was lower in the CNN-enhanced images compared with standard 1 min and 1.5 min images. Physicians ranked the 1.5 min CNN and the 4 min images highest regarding image quality (noise and contrast) and the standard 1 min images lowest. Conclusions AI can enhance [18F]FDG-PET images to reduce noise and increase contrast compared with standard images whilst keeping SUVmax/peak stability. There were significant differences in scoring between the 1.5 min and 1.5 min CNN image sets in all comparisons, the latter had higher scores in noise and contrast. Furthermore, difference in SUVmax and SUVpeak fell short of significance for that pair. The improved image quality can potentially be used either to provide better images to the nuclear medicine physicians or to reduce acquisition time/administered activity.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.