scholarly journals Use of the A2DS2 scale to predict morbidity in stroke-associated pneumonia: a systematic review and meta-analysis

BMC Neurology ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jie Huang ◽  
Ming Liu ◽  
Weiliang He ◽  
Feifei Liu ◽  
Jinming Cheng ◽  
...  

Abstract Background This review aims to evaluate the performance and clinical applicability of the A2DS2 scale via systematic review and meta-analysis. Methods The Medline, Embase, Cochrane Library, CBM, CNKI, and Wanfang databases were searched. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Funnel plots and Egger’s test were used to evaluate publication bias. The bivariate random-effect model was used for calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC). A Fagan nomogram was applied to evaluate the clinical applicability of the A2DS2 scale. Results A total of 29 full-text articles met the inclusion criteria, including 19,056 patients. Bivariate mixed-effects regression models yielded a mean sensitivity of 0.78 (95 % CI: 0.73–0.83), a specificity of 0.79 (95 % CI: 0.73–0.84), a positive likelihood ratio of 3.7 (95 % CI: 2.9–4.6), and a negative likelihood ratio of 0.27 (95 % CI: 0.23–0.33). The area under the receiver operating characteristic curve was 0.85 (95 % CI: 0.82–0.88). If given a pre-test probability of 50 %, the Fagan nomogram showed that when A2DS2 was positive, the post-test probability improved to 79 %. In contrast, when A2DS2 was negative, it decreased to 22 %. The results of the subgroup analysis showed no effect on the diagnostic accuracy of the A2DS2 scale in predicting stroke-associated pneumonia, except for the optimal cut-off value. Conclusions The A2DS2 scale demonstrates high clinical applicability and could be a valid scale for the early prediction of stroke-associated pneumonia in stroke patients.

BMJ Open ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. e033084 ◽  
Author(s):  
Jin-Rong Ni ◽  
Pei-Jing Yan ◽  
Shi-Dong Liu ◽  
Yuan Hu ◽  
Ke-Hu Yang ◽  
...  

ObjectiveTo evaluate the diagnostic accuracy of transthoracic echocardiography (TTE) in patients with pulmonary hypertension (PH).DesignSystematic review and meta-analysis.Data sources and eligibility criteriaEmbase, Cochrane Library for clinical trials, PubMed and Web of Science were used to search studies from inception to 19 June, 2019. Studies using both TTE and right heart catheterisation (RHC) to diagnose PH were included.Main resultsA total of 27 studies involving 4386 subjects were considered as eligible for analysis. TTE had a pooled sensitivity of 85%, a pooled specificity of 74%, a pooled positive likelihood ratio of 3.2, a pooled negative likelihood ratio of 0.20, a pooled diagnostic OR of 16 and finally an area under the summary receiver operating characteristic curve of 0.88. The subgroup with the shortest time interval between TTE and RHC had the best diagnostic effect, with sensitivity, specificity and area under the curve (AUC) of 88%, 90% and 0.94, respectively. TTE had lower sensitivity (81%), specificity (61%) and AUC (0.73) in the subgroup of patients with definite lung diseases. Subgroup analysis also showed that different thresholds of TTE resulted in a different diagnostic performance in the diagnosis of PH.ConclusionTTE has a clinical value in diagnosing PH, although it cannot yet replace RHC considered as the gold standard. The accuracy of TTE may be improved by shortening the time interval between TTE and RHC and by developing an appropriate threshold. TTE may not be suitable to assess pulmonary arterial pressure in patients with pulmonary diseases.PROSPERO registration numberPROSPERO CRD42019123289.


2016 ◽  
Vol 38 (3) ◽  
pp. 939-949 ◽  
Author(s):  
Li-hua Xu ◽  
Yang Guo ◽  
Xue-Li Zhang ◽  
Jia-jia Chen ◽  
Shao-yan Hu

Aims: Circulating microRNAs (miRNAs) as biomarkers for leukemia have been validated by emerging studies. This meta-analysis aims to estimate the overall diagnostic accuracy of blood-based circulating miRNAs for leukemia. Methods: We searched multiple databases (PubMed, EMBASE, Cochrane Library, CNKI, Wan Fang Data and CQVIP) up to June 18, 2015. Results: 32 studies from 10 publications were included in this meta-analysis. Diagnostic capacity was evaluated by pooled sensitivity, specifIcity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) through random-effects model. Sensitivity analyses were sequentially performed to find potential sources of heterogeneity. The quality of included studies was assessed by QUADAS (quality assessment for studies of diagnostic accuracy). Meta-Disc 1.4 and Stata 12.0 software were used to perform the meta-analysis. A high diagnostic accuracy was displayed, with a sensitivity of 0.84, a specificity of 0.88, a PLR of 7.20, a NLR of 0.18, a DOR of 52, and an AUC of 0.94. Subgroup analyses revealed better performance for combined miRNAs, acute myeloid leukemia patients and Asian population than other subgroups. Conclusion: Our analyses suggested that blood-based circulating miRNAs are promising diagnostic biomarkers for leukemia, especially combined miRNAs. Its clinical application awaits further study.


2019 ◽  
Author(s):  
Qindong Liang ◽  
Guangjie Zhang ◽  
Huaan Huang ◽  
Nai Xing ◽  
Shangchun Sheng ◽  
...  

Abstract Background Mounting studies reported that circulating pentraxin 3 (PTX3) expression level was significantly different between cancer patients and healthy groups, suggesting that PTX3 may be a potential biomarker for cancer detection. However, the results were inconsistent. In this paper, a systematic review and meta-analysis was performed to quantitatively assess the diagnostic value of PTX3 in cancer detection.Methods A comprehensive computerized literature search was conducted in Embase, PubMed, Cochrane Library, Web of Science, Chinese National Knowledge Infrastructure (CNKI) from inception to July 31, 2019. Eligible studies were identified and raw data were extracted. Diagnostic estimates were synthesized using STATA (version 12.0) and MetaDisc (version 1.4) statistical software.Results Overall, 9 studies from 8 citations with a total of 1408 cancer patiens and 3116 controls were included in this meta-analysis. The global sensitivity was 0.70 (95% confidence interval (CI): 0.67 – 0.72), and the specificity was 0.77 (95% CI: 0.75 – 0.78). The pooled positive likelihood ratio (PLR), negative likelihood ratio (NLR), and the diagnostic odds ratio (DOR) were 2.86 (95% CI: 2.29 – 3.56), 0.40 (95% CI: 0.32 – 0.50) and 7.38 (95% CI: 5.05 – 10.78), respectively. The merged AUC was 0.80 (95% CI: 0.76 – 0.83).Conclusion The serum PTX3 appears to be a reliable biomarker for cancer detection though large-scale multicenter studies are needed.


2018 ◽  
Vol 45 (3) ◽  
pp. 962-972 ◽  
Author(s):  
Zhiqiang Chen ◽  
Long Zhang ◽  
Guoyong Han ◽  
Xueliang Zuo ◽  
Yao Zhang ◽  
...  

Background/Aims: Circular RNAs (circRNAs), a novel class of noncoding RNAs, have been found to be dysregulated in various cancers. However, the clinical application value of these circRNAs in digestive system cancers remains to be clarified. We aimed to comprehensively explore the potential role of circRNAs as diagnostic indicators in digestive system malignancies. Methods: Relevant studies were systematically retrieved from PubMed, Web of Science and the Cochrane Library. The data that were required to complete 2 × 2 contingency tables were obtained from the included studies. Stratified analyses by cancer type, sample size and publication year were performed. Results: Thirteen studies with 2,276 individuals were included in the meta-analysis. The pooled sensitivity and specificity of circRNAs in the diagnosis of digestive system malignancy were 0.72 [95% confidence interval (CI): 0.65-0.77] and 0.77 (95% CI: 0.72-0.81), respectively. The overall positive likelihood ratio was 3.09 (95% CI: 2.64-3.62), and the overall negative likelihood ratio was 0.37 (95% CI: 0.31-0.44). The pooled diagnostic odds ratio was 8.38 (95% CI: 6.86-10.25), and the overall area under the curve was 0.81 (95% CI: 0.77-0.84), indicating good discriminative ability of circRNAs as biomarkers for digestive system malignancy. Conclusion: circRNAs distinguish patients with digestive system cancer from controls with relatively high diagnostic accuracy. circRNAs may be used as potential biomarkers for the diagnosis of digestive system malignancy.


2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
Fengyi Wang ◽  
Jiaqi Zhang ◽  
Jiadan Yu ◽  
Shaxin Liu ◽  
Rengang Zhang ◽  
...  

Objective. To systematically evaluate the diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy. Methods. We searched EMBASE (OvidSP), MEDLINE (OvidSP), the Cochrane Library, and Web of Science to identify diagnostic accuracy trials of monofilament tests for detecting diabetic peripheral neuropathy. We used a hierarchical summary receiver operating characteristics (HSROC) model to conduct the meta-analysis of diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy. Results. A total of 19 comparative trials met the inclusion criteria and were part of the qualitative synthesis. Eight trials using nerve conduction studies as the reference standard were selected for the meta-analysis. The pooled sensitivity and specificity of monofilament tests for detecting diabetic peripheral neuropathy were 0.53 (95% confidence interval (CI) 0.32 to 0.74) and 0.88 (95% CI 0.78 to 0.94), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 4.56 (95% CI 2.93 to 7.10) and 0.53 (95% CI 0.35 to 0.81), respectively. Conclusions. Our review indicated that monofilament tests had limited sensitivity for screening diabetic peripheral neuropathy. The clinical use of the monofilament test in the evaluation of diabetic peripheral neuropathy cannot be encouraged based on currently available evidence.


BMJ Open ◽  
2019 ◽  
Vol 9 (4) ◽  
pp. e025222 ◽  
Author(s):  
Xia Qiu ◽  
Jinhui Li ◽  
Xiaoyan Yang ◽  
Jun Tang ◽  
Jing Shi ◽  
...  

ObjectivesOur study aimed to synthesise and analyse the early diagnostic value of neutrophil CD11b (nCD11b) for neonatal sepsis.DesignSystematic review and meta-analysis.MethodsPubmed, Embase, the Cochrane Library and Web of Science Databases were searched up to June 2018. We used Stata software (V.14.0) to conduct the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic OR (DOR), pretest probability, post-test probability and summary receiver operating characteristic (SROC) curve for diagnostic efficiency of n CD11b.ResultsNine studies, accounting for 843 neonates, were included. The overall pooled sensitivity, specificity, PLR, NLR, DOR, post-test positive probability and post-test negative probability and the area under the SROC curve were 0.82 (95% CI 0.71 to 0.90), 0.93 (95% CI 0.62 to 0.99), 11.51 (95% CI 1.55 to 85.62), 0.19 (95% CI 0.10 to 0.36), 59.50 (95% CI 4.65 to 761.58), 74%, 5% and 0.90, which had accuracy in diagnosing neonatal sepsis.ConclusionThe present evidence indicated that nCD11b is a promising biomarker for the early diagnosis of neonatal sepsis.


Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1081
Author(s):  
Ernest Osei ◽  
Sphamandla Josias Nkambule ◽  
Portia Nelisiwe Vezi ◽  
Tivani P. Mashamba-Thompson

Mobile health devices are emerging applications that could help deliver point-of-care (POC) diagnosis, particularly in settings with limited laboratory infrastructure, such as Sub-Saharan Africa (SSA). The advent of Severe acute respiratory syndrome coronavirus 2 has resulted in an increased deployment and use of mHealth-linked POC diagnostics in SSA. We performed a systematic review and meta-analysis to evaluate the accuracy of mobile-linked point-of-care diagnostics in SSA. Our systematic review and meta-analysis were guided by the Preferred Reporting Items requirements for Systematic Reviews and Meta-Analysis. We exhaustively searched PubMed, Science Direct, Google Scholar, MEDLINE, and CINAHL with full text via EBSCOhost databases, from mHealth inception to March 2021. The statistical analyses were conducted using OpenMeta-Analyst software. All 11 included studies were considered for the meta-analysis. The included studies focused on malaria infections, Schistosoma haematobium, Schistosoma mansoni, soil-transmitted helminths, and Trichuris trichiura. The pooled summary of sensitivity and specificity estimates were moderate compared to those of the reference representing the gold standard. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of mobile-linked POC diagnostic devices were as follows: 0.499 (95% CI: 0.458–0.541), 0.535 (95% CI: 0.401–0.663), 0.952 (95% CI: 0.60–1.324), 1.381 (95% CI: 0.391–4.879), and 0.944 (95% CI: 0.579–1.538), respectively. Evidence shows that the diagnostic accuracy of mobile-linked POC diagnostics in detecting infections in SSA is presently moderate. Future research is recommended to evaluate mHealth devices’ diagnostic potential using devices with excellent sensitivities and specificities for diagnosing diseases in this setting.


2021 ◽  
Author(s):  
Wu Chen ◽  
Kun Xu ◽  
Yiying Li ◽  
Meifang Hao ◽  
Yongsheng Yang ◽  
...  

Aims: The present study investigated and evaluated the accuracy of thoracic ultrasonography (TUS) in the diagnosis of pulmonary embolism (PE) by conducting a systematic review and meta-analysis. Material and methods: The PubMed, Em-base and the Cochrane library databases were searched till March 2019 to retrieve relevant articles and the overall diagnostic accuracy of TUS in PE diagnosis was evaluated by meta-analysis. Results: Overall, 16 studies including 1,916 patients were enrolled in this meta-analysis. Of these, 762 (39.8%) had confirmed PE. The overall sensitivity, specificity, and area under the ROC curve (AUC) of TUS for PE were 82% (95% confidence interval (CI), 72%–88%), 89% (95% CI, 79%–95%), and 0.91 (95% CI, 0.88–0.93), respectively. Other efficacy parameters assessed demonstrated a positive likelihood ratio (PLR) of (7.6; 95% CI, 4.0–14.5), negative likelihood ratio of (NLR) (0.21; 95% CI, 0.14–0.30), and diagnostic odds’ ratio (DOR) of (36.86; 95% CI, 21.41–63.48). Conclusions: The current study suggested that although TUS cannot safely rule out PE, it is likely to be used as an aid or guidance to establish procedures and help to improve the diagnostic deficits in patients with PE.


2020 ◽  
Author(s):  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Pengfei Xin ◽  
Xingyang Zhu ◽  
Ke Jie ◽  
...  

Abstract Background: Periprosthetic joint infection (PJI) is one of the most devastating complications after total joint replacement. Up to now, the diagnosis of PJI is still in a dilemma. As a novel biomarker, whether D-Dimer is valuable in the diagnosis of PJI remains controversial. This meta-analysis attempts to determine the diagnostic accuracy of D-Dimer in PJI.Methods: Relevant literature was retrieved from PubMed, Embase, Web of Science, and Cochrane Library (from database establishment to April 2020). Literature quality was evaluated using Revman (Version 5.3). The random effect model was used in Stata version 14.0 software to combine sensitivity, specificity, likelihood ratio (LR), diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curve and area under SROC (AUC) to evaluate the diagnostic value of overall D-Dimer for PJI. Meta regression and subgroup analysis were performed according to the threshold, the study design, the sample size, the diagnostic gold standard, the country of study, and the type of sample.Results:A total of 9 studies were included in this study, including 1592 patients. The pooled sensitivity and specificity of D-Dimer for PJI diagnosis are 0.82(95%CI, 0.72~0.89) and 0.73(95%CI, 0.58~0.83), respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 2.99 (95%CI, 1.84~4.88) and 0.25 (95%CI, 0.15~0.41), respectively. The pooled AUC and diagnostic odds ratios were 0.85 (95%CI, 0.82~0.88) and 12.20 (95% CI, 4.98~29.86), respectively.Conclusion: D-Dimer is a promising biomarker for the diagnosis of PJI, which should be used in conjunction with other biomarkers or as an adjunct to other diagnostic methods to enhance diagnostic performance.


2020 ◽  
Author(s):  
Wen-Ting Zhang ◽  
Shuai-Shuai Gao ◽  
Yan-Jun Wang ◽  
Guo-Xun Zhang

Abstract Multiple myeloma (MM) is the second incurable hematological malignancy. In recent years, due to the rise of microRNA (miRNA), many scholars have participated in the study of its value in the diagnosis of MM, and have obtained good but inconsistent results. Therefore, in order to determine the role of miRNA in the early diagnosis of MM, we searched for related studies including PubMed, Web of Science, EMBASE, Cochrane Library, China National Knowledge Infrastructure (CNKI) and Wanfang Database as of July 20, 2020 to conduct this meta-analysis. To improve the accuracy, the quality assessment of Diagnostic Accuracy Study 2 (QUADAS-2) was used. We also applied random effects models to summarize sensitivity and specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and area under the curve (AUC) to measure diagnostic values, and subgroup analysis used to discover potential sources of heterogeneity. Finally, we collected 32 studies from 15 articles that included a total of 2053 MM patients and 1118 healthy controls. The overall sensitivity, specificity, PLR, NLR, DOR and AUC were 0.81, 0.85, 5.5, 0.22, 25 and 0.90, respectively. Subgroup analysis shows that the down-regulation of microRNA clusters with larger samples size of plasma type could carry out a better diagnostic accuracy of MM patients. In addition, publication bias was not found. In conclusion, circulating miRNA could be a potential non-invasive biomarker for early diagnosis of MM. However, multi-center, more rigorous, and larger-scale studies are needed to verify our conclusions.


Sign in / Sign up

Export Citation Format

Share Document