scholarly journals Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study

BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jie Wang ◽  
Li Min ◽  
Minxun Lu ◽  
Yuqi Zhang ◽  
Jingqi Lin ◽  
...  

Abstract Background The aims of this pilot study were (1) to assess the efficacy of 3D-printed custom-made hemipelvic endoprosthesis in restoring the natural location of acetabulum for normal bodyweight transmission; (2) to evaluate the short-term function of the revision with this endoprosthesis and (3) to identify short-term complications associated with the use of this endoprosthesis. Methods Between February 2017 and December 2017, seven patients received revision with 3D-printed custom-made hemipelvic endoprosthesis. The body weight moment arm (BWMA) and cup height discrepancy (CHD) after primary and revisional surgery were analyzed to assess acetabulum location with plain radiography. After a median follow-up duration of 29 months (range 24–34), the function was evaluated with the Musculoskeletal Tumor Society (MSTS-93) score and Harris hip score (HHS). Complications were recorded by chart review. Results The acetabulum locations were deemed reasonable, as evaluated by median BWMA (primary vs. revision, 10 cm vs. 10 cm) and median CHD (primary vs. revision, 10 mm vs. 8 mm). The median MSTS-93 score and HHS score were 21 (range 18–23) and 78 (range 75–82) after the revision. No short or mid-term complication was observed in the follow-up of this series. Conclusions Revision with 3D-printed custom-made hemipelvic endoprostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening and fracture of modular hemipelvic endoprosthesis. The revision surgery and appropriate rehabilitation program improved patients’ function to a median MSTS score of 22 and pain-free ambulation. The incidence of the complications was low via this individualized workflow.

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Jie Wang ◽  
Jingjing An ◽  
Minxun Lu ◽  
Yuqi Zhang ◽  
Jingqi Lin ◽  
...  

Abstract Background Long-lasting reconstruction after extensive resection involving peri-knee metaphysis is a challenging problem in orthopedic oncology. Various reconstruction methods have been proposed, but they are characterized by a high complication rate. The purposes of this study were to (1) assess osseointegration at the bone implant interface and correlated incidence of aseptic loosening; (2) identify complications including infection, endoprosthesis fracture, periprosthetic fracture, leg length discrepancy, and wound healing problem in this case series; and (3) evaluate the short-term function of the patient who received this personalized reconstruction system. Methods Between September 2016 and June 2018, our center treated 15 patients with malignancies arising in the femur or tibia shaft using endoprosthesis with a 3D-printed custom-made stem. Osseointegration and aseptic loosening were assessed with digital tomosynthesis. Complications were recorded by reviewing the patients’ records. The function was evaluated with the 1993 version of the Musculoskeletal Tumor Society (MSTS-93) score at a median of 42 (range, 34 to 54) months after reconstruction. Results One patient who experienced early aseptic loosening was managed with immobilization and bisphosphonates infusion. All implants were well osseointegrated at the final follow-up examination. There are two periprosthetic fractures intraoperatively. The wire was applied to assist fixation, and the fracture healed at the latest follow-up. Two patients experienced significant leg length discrepancies. The median MSTS-93 score was 26 (range, 23 to 30). Conclusions A 3D-printed custom-made ultra-short stem with a porous structure provides acceptable early outcomes in patients who received peri-knee metaphyseal reconstruction. With detailed preoperative design and precise intraoperative techniques, the reasonable initial stability benefits osseointegration to osteoconductive porous titanium, and therefore ensures short- and possibly long-term durability. Personalized adaptive endoprosthesis, careful intraoperative operation, and strict follow-up management enable effective prevention and treatment of complications. The functional results in our series were acceptable thanks to reliable fixation in the bone-endoprosthesis interface and an individualized rehabilitation program. These positive results indicate this device series can be a feasible alternative for critical bone defect reconstruction. Nevertheless, longer follow-up is required to determine whether this technique is superior to other forms of fixation.


2021 ◽  
Vol 10 (5) ◽  
pp. 1056
Author(s):  
Giovanni Beltrami ◽  
Gabriele Ristori ◽  
Anna Maria Nucci ◽  
Alberto Galeotti ◽  
Angela Tamburini ◽  
...  

Recently, custom-made 3D-printed prostheses have been introduced for limb salvage surgery in adult patients, but their use has not been described in pediatric patients. A series of 11 pediatric patients (mean age 10.8 years; range 2–13) with skeletal tumors treated with custom-made implants for the reconstruction of bony defects is described. Patients were followed up every 3 months. Functional results were evaluated by the Musculoskeletal Tumor Society Score (MSTS) for upper and lower limbs. The mean follow-up was 25.7 months (range 14–44). Three patients died after a mean of 19.3 months postoperatively—two because of disease progression and the other from a previous malignancy. Three patients experienced complications related to soft tissues. One patient required device removal, debridement, and antibiotic pearls for postoperative infection. Partial osseointegration between grafts and host bone was observed within a mean of 4 months. At the final follow-up, mean MSTS score was 75%. 3D prostheses may yield biological advantages due to possible integration with the host bone and also through the use of vascularized flaps. Further research is warranted.


2021 ◽  
Vol 14 (7) ◽  
pp. e241090
Author(s):  
Mario Igor Rossello

Following wrist trauma due to a karate accident, an 18-year-old male patient developed non-union of the scaphoid with proximal pole necrosis and significant scapholunate gap from an evident scapholunate interosseous ligament (SLIL) injury. A custom-made 3D-printed titanium implant was used for scaphoid replacement and SLIL reconstruction. Good clinical and radiographic outcomes were observed at his 2-year follow-up. Custom-made 3D-printed titanium implants are thought to provide a surgical solution for patients requiring site-specific scaphoid replacement while allowing the reconstruction of the scapholunate ligament.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 707
Author(s):  
Jong-Woong Park ◽  
Hyun-Guy Kang ◽  
June-Hyuk Kim ◽  
Han-Soo Kim

In orthopedic oncology, revisional surgery due to mechanical failure or local recurrence is not uncommon following limb salvage surgery using an endoprosthesis. However, due to the lack of clinical experience in limb salvage surgery using 3D-printed custom-made implants, there have been no reports of revision limb salvage surgery using a 3D-printed implant. Herein, we present two cases of representative revision limb salvage surgeries that utilized another 3D-printed custom-made implant while retaining the previous 3D-printed custom-made implant. A 3D-printed connector implant was used to connect the previous 3D-printed implant to the proximal ulna of a 40-year-old man and to the femur of a 69-year-old woman. The connector bodies for the two junctions of the previous implant and the remaining host bone were designed for the most functional position or angle by twisting or tilting. Using the previous 3D-printed implant as a taper, the 3D-printed connector was used to encase the outside of the previous implant. The gap between the previous implant and the new one was subsequently filled with bone cement. For both the upper and lower extremities, the 3D-printed connector showed stable reconstruction and excellent functional outcomes (Musculoskeletal Tumor Society scores of 87% and 100%, respectively) in the short-term follow-up. To retain the previous 3D-printed implant during revision limb salvage surgery, an additional 3D-printed implant may be a feasible surgical option.


2013 ◽  
Vol 17 (4) ◽  
pp. 418-422 ◽  
Author(s):  
Lilian Chrystiane Giannasi ◽  
Israel Reis Santos ◽  
Thays Almeida Alfaya ◽  
Sandra Kalil Bussadori ◽  
Luis Vicente Franco de Oliveira

2020 ◽  
Vol 58 (10) ◽  
pp. e175
Author(s):  
Daniel Bradley ◽  
Calum Honeyman ◽  
Vinod Patel ◽  
Julian Zeolla ◽  
Lucy Lester ◽  
...  

2003 ◽  
Vol 13 (2) ◽  
pp. 94-100
Author(s):  
M.J.F. Diks ◽  
M. Spruit ◽  
J.J. Reimering ◽  
F. Den Boer ◽  
P.G. Anderson

Aseptic loosening in total hip arthroplasty can lead to proximal femoral periprosthetic bone loss. The non-cemented Wagner revision stem achieves primary fixation in the diaphysis. The purpose of this study is to evaluate the results after medium- to long-term follow-up of the Wagner prosthesis for revision of the femoral component for aseptic loosening in total hip arthroplasty with proximal femoral bone loss. We performed 53 femoral revisions for aseptic loosening with the non-cemented Wagner revision stem. Clinical assessment included a modified Harris Hip Score and a radiological evaluation. The mean follow-up was 65 months. The Harris Hip Score improved significantly (42.9 to 72.3). Radiological evaluation revealed 24.5% subsidence (>5 mm) in our population. Nine re-revisions were done, eight in the first post-operative year. The re-revisions were performed for progressive subsidence (five), recurrent dislocations (one), subsidence with low-grade infection (one), false route (one), and aseptic loosening after 75 months (one). The cumulative survival rate of the Wagner stem after 12 months was 85% and 76% after 75 months. A relatively high re-revision rate was observed during the first post-operative year. Analysis of these failures has shown that subsidence may be the result of insufficient primary stability. Adequate pre-operative planning and intra-operative radiological assistance is necessary for perfect primary stability and fixation of the Wagner stem. The re-revision incidence after the first 12 months is 0.45 per 100 implants per year. The prosthesis has good survival potential after proper introduction.


2018 ◽  
Vol 26 (2) ◽  
pp. 230949901877788 ◽  
Author(s):  
Saeed Ahmad ◽  
Irfan Qadir ◽  
Atiq uz Zaman ◽  
Chiragh Muhammad Khan ◽  
Shahzad Javed ◽  
...  

Introduction: Treatment of developmental dysplasia of hip (DDH) diagnosed after 10 years of age is extremely difficult because of the soft tissue and bone deformities. In this study, we evaluated short-term results of a single-stage procedure performed with surgical hip dislocation, femoral shortening and capsular arthroplasty. Patients and Methods: A retrospective review of charts of five patients with DDH, older than 10 years, who underwent capsular arthroplasty at Ghurki Trust Teaching Hospital between 2013 and 2015 was performed. Post-operative functional evaluation was performed using modified McKay’s scoring system and radiographic assessment using Severin’s scoring method at a minimum of 2-year follow-up. Results: We present results of five patients (six hips) with a mean age of 18.16 years. All patients had limping gait and International Hip dysplasia Institute classification (IHDI) class 4 hip dislocation. Harris hip score showed a significant improvement (53.13 vs 84.16; p = 0.0001). Femoral shortening of 2–2.5 cm was done. Additional shelf procedure was required in one patient. This patient persistently has post-operative hip subluxation. All patients had good to excellent outcomes according to McKay classification. Post-operative Severin classification was 1A in all patients. No case of avascular necrosis of the femoral head was noted during the follow-up. Conclusion: Capsular arthroplasty with subtrochanteric shortening is a useful procedure for neglected cases of DDH in patients older than 10 years.


2015 ◽  
Vol 60 (2) ◽  
pp. 833-837 ◽  
Author(s):  
María Gabriela Álvarez ◽  
Yolanda Hernández ◽  
Graciela Bertocchi ◽  
Marisa Fernández ◽  
Bruno Lococo ◽  
...  

ABSTRACTThere is a clinical need to test new schemes of benznidazole administration that are expected to be at least as effective as the current therapeutic scheme but safer. This study assessed a new scheme of benznidazole administration in chronic Chagas disease patients. A pilot study with intermittent doses of benznidazole at 5 mg/kg/day in two daily doses every 5 days for a total of 60 days was designed. The main criterion of response was the comparison of quantitative PCR (qPCR) findings prior to and 1 week after the end of treatment. The safety profile was assessed by the rate of suspensions and severity of adverse effects. Twenty patients were analyzed for safety, while qPCR was tested for 17 of them. The average age was 43 ± 7.9 years; 55% were female. Sixty-five percent of treated subjects showed detectable qPCR results prior to treatment of 1.45 (0.63 to 2.81) and 2.1 (1.18 to 2.78) parasitic equivalents per milliliter of blood (par.eq/ml) for kinetoplastic DNA (kDNA) qPCR and nuclear repetitive sequence satellite DNA (SatDNA) qPCR, respectively. One patient showed detectable PCR at the end of treatment (1/17), corresponding to 6% treatment failure, compared with 11/17 (65%) patients pretreatment (P= 0.01). Adverse effects were present in 10/20 (50%) patients, but in only one case was treatment suspended. Eight patients showed mild adverse effects, whereas moderate reactions with increased liver enzymes were observed in two patients. The main accomplishment of this pilot study is the promising low rate of treatment suspension. Intermittent administration of benznidazole emerges a new potential therapeutic scheme, the efficacy of which should be confirmed by long-term assessment posttreatment.


2018 ◽  
Vol 28 (6) ◽  
pp. 668-674 ◽  
Author(s):  
David C Kieser ◽  
Ramez Ailabouni ◽  
Sandra C J Kieser ◽  
Michael C Wyatt ◽  
Paul C Armour ◽  
...  

Introduction: Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. Methods: This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Results: Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. Conclusions: The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.


Sign in / Sign up

Export Citation Format

Share Document