scholarly journals Is three-dimensional–printed custom-made ultra-short stem with a porous structure an acceptable reconstructive alternative in peri-knee metaphysis for the tumorous bone defect?

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Jie Wang ◽  
Jingjing An ◽  
Minxun Lu ◽  
Yuqi Zhang ◽  
Jingqi Lin ◽  
...  

Abstract Background Long-lasting reconstruction after extensive resection involving peri-knee metaphysis is a challenging problem in orthopedic oncology. Various reconstruction methods have been proposed, but they are characterized by a high complication rate. The purposes of this study were to (1) assess osseointegration at the bone implant interface and correlated incidence of aseptic loosening; (2) identify complications including infection, endoprosthesis fracture, periprosthetic fracture, leg length discrepancy, and wound healing problem in this case series; and (3) evaluate the short-term function of the patient who received this personalized reconstruction system. Methods Between September 2016 and June 2018, our center treated 15 patients with malignancies arising in the femur or tibia shaft using endoprosthesis with a 3D-printed custom-made stem. Osseointegration and aseptic loosening were assessed with digital tomosynthesis. Complications were recorded by reviewing the patients’ records. The function was evaluated with the 1993 version of the Musculoskeletal Tumor Society (MSTS-93) score at a median of 42 (range, 34 to 54) months after reconstruction. Results One patient who experienced early aseptic loosening was managed with immobilization and bisphosphonates infusion. All implants were well osseointegrated at the final follow-up examination. There are two periprosthetic fractures intraoperatively. The wire was applied to assist fixation, and the fracture healed at the latest follow-up. Two patients experienced significant leg length discrepancies. The median MSTS-93 score was 26 (range, 23 to 30). Conclusions A 3D-printed custom-made ultra-short stem with a porous structure provides acceptable early outcomes in patients who received peri-knee metaphyseal reconstruction. With detailed preoperative design and precise intraoperative techniques, the reasonable initial stability benefits osseointegration to osteoconductive porous titanium, and therefore ensures short- and possibly long-term durability. Personalized adaptive endoprosthesis, careful intraoperative operation, and strict follow-up management enable effective prevention and treatment of complications. The functional results in our series were acceptable thanks to reliable fixation in the bone-endoprosthesis interface and an individualized rehabilitation program. These positive results indicate this device series can be a feasible alternative for critical bone defect reconstruction. Nevertheless, longer follow-up is required to determine whether this technique is superior to other forms of fixation.

BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jie Wang ◽  
Li Min ◽  
Minxun Lu ◽  
Yuqi Zhang ◽  
Jingqi Lin ◽  
...  

Abstract Background The aims of this pilot study were (1) to assess the efficacy of 3D-printed custom-made hemipelvic endoprosthesis in restoring the natural location of acetabulum for normal bodyweight transmission; (2) to evaluate the short-term function of the revision with this endoprosthesis and (3) to identify short-term complications associated with the use of this endoprosthesis. Methods Between February 2017 and December 2017, seven patients received revision with 3D-printed custom-made hemipelvic endoprosthesis. The body weight moment arm (BWMA) and cup height discrepancy (CHD) after primary and revisional surgery were analyzed to assess acetabulum location with plain radiography. After a median follow-up duration of 29 months (range 24–34), the function was evaluated with the Musculoskeletal Tumor Society (MSTS-93) score and Harris hip score (HHS). Complications were recorded by chart review. Results The acetabulum locations were deemed reasonable, as evaluated by median BWMA (primary vs. revision, 10 cm vs. 10 cm) and median CHD (primary vs. revision, 10 mm vs. 8 mm). The median MSTS-93 score and HHS score were 21 (range 18–23) and 78 (range 75–82) after the revision. No short or mid-term complication was observed in the follow-up of this series. Conclusions Revision with 3D-printed custom-made hemipelvic endoprostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening and fracture of modular hemipelvic endoprosthesis. The revision surgery and appropriate rehabilitation program improved patients’ function to a median MSTS score of 22 and pain-free ambulation. The incidence of the complications was low via this individualized workflow.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 707
Author(s):  
Jong-Woong Park ◽  
Hyun-Guy Kang ◽  
June-Hyuk Kim ◽  
Han-Soo Kim

In orthopedic oncology, revisional surgery due to mechanical failure or local recurrence is not uncommon following limb salvage surgery using an endoprosthesis. However, due to the lack of clinical experience in limb salvage surgery using 3D-printed custom-made implants, there have been no reports of revision limb salvage surgery using a 3D-printed implant. Herein, we present two cases of representative revision limb salvage surgeries that utilized another 3D-printed custom-made implant while retaining the previous 3D-printed custom-made implant. A 3D-printed connector implant was used to connect the previous 3D-printed implant to the proximal ulna of a 40-year-old man and to the femur of a 69-year-old woman. The connector bodies for the two junctions of the previous implant and the remaining host bone were designed for the most functional position or angle by twisting or tilting. Using the previous 3D-printed implant as a taper, the 3D-printed connector was used to encase the outside of the previous implant. The gap between the previous implant and the new one was subsequently filled with bone cement. For both the upper and lower extremities, the 3D-printed connector showed stable reconstruction and excellent functional outcomes (Musculoskeletal Tumor Society scores of 87% and 100%, respectively) in the short-term follow-up. To retain the previous 3D-printed implant during revision limb salvage surgery, an additional 3D-printed implant may be a feasible surgical option.


2021 ◽  
Vol 10 (5) ◽  
pp. 1056
Author(s):  
Giovanni Beltrami ◽  
Gabriele Ristori ◽  
Anna Maria Nucci ◽  
Alberto Galeotti ◽  
Angela Tamburini ◽  
...  

Recently, custom-made 3D-printed prostheses have been introduced for limb salvage surgery in adult patients, but their use has not been described in pediatric patients. A series of 11 pediatric patients (mean age 10.8 years; range 2–13) with skeletal tumors treated with custom-made implants for the reconstruction of bony defects is described. Patients were followed up every 3 months. Functional results were evaluated by the Musculoskeletal Tumor Society Score (MSTS) for upper and lower limbs. The mean follow-up was 25.7 months (range 14–44). Three patients died after a mean of 19.3 months postoperatively—two because of disease progression and the other from a previous malignancy. Three patients experienced complications related to soft tissues. One patient required device removal, debridement, and antibiotic pearls for postoperative infection. Partial osseointegration between grafts and host bone was observed within a mean of 4 months. At the final follow-up, mean MSTS score was 75%. 3D prostheses may yield biological advantages due to possible integration with the host bone and also through the use of vascularized flaps. Further research is warranted.


2018 ◽  
Vol 100-B (12) ◽  
pp. 1640-1646 ◽  
Author(s):  
M. R. Medellin ◽  
T. Fujiwara ◽  
R. Clark ◽  
L. M. Jeys

AimsThe aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses.Patients and MethodsA total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System.ResultsThe overall implant survival was 79% at five, ten, and 20 years for MI prostheses, and 84% at five years and 70% at ten years for NI prostheses. At the final follow-up, 13 prostheses did not require further surgery. The overall complication rate was 46%. The mean revision-free implant survival for MI and NI prostheses was 59 months and 49 months, respectively. There were no statistically significant differences in the overall implant survival, revision-free survival, or the distribution of complications between the two types of prosthesis. Infection rates were also comparable in the groups (9% vs 7%; p = 0.902). The rate of leg-length discrepancy was 54% in MI prostheses and 23% in NI prostheses. In those with a MI prosthesis, there was a smaller mean range of movement of the knee (0° to 62° vs 0° to 83°; p = 0.047), the flexion contracture took a longer mean time to resolve after lengthening (3.3 months vs 1.07 months; p < 0.001) and there was a lower mean Musculoskeletal Tumor Society (MSTS) score (24.7 vs 27; p = 0.295).ConclusionThe survival and complications of MI and NI lengthening total femoral prostheses are comparable. However, patients with NI prosthesis have more accurate correction of leg-length discrepancy, a better range of movement of the knee and an improved overall function.


2018 ◽  
Vol 29 (6) ◽  
pp. 603-608 ◽  
Author(s):  
Yingyong Suksathien ◽  
Jithayut Sueajui

Purpose: To evaluate the clinical and radiographic mid-term results of short-stem total hip arthroplasty (THA) in patients with osteonecrosis of the femoral head (ONFH). Methods: We reviewed 83 cases that underwent Metha stem between November 2010 and November 2012. The appearance of bone trabeculae development and radiolucent line were reviewed and HHS was recorded at 6 months postoperatively then yearly to evaluate the clinical results. Results: The mean age of patients was 43.8 years with the mean follow-up 69.3 (60–84) months. Harris Hip Score improved significantly from 44.7 preoperatively to 99.6 at the last follow-up ( p < 0.0001). There were 4 cases (4.8%) of intraoperative femoral fractures. There was 1 case (1.2%) of distal stem perforation that had stable bone ingrowth and there was 1 case (1.2%) of 5-mm subsidence, which was then stable at 3 months postoperatively. Bone trabecular development was detected at zone 1 (65.1%), 2 (69.9%), 3 (14.4%), 4 (1.2%), 6 (97.6%) and 7 (81.9%). There was 1 case (1.2%) where radiolucent lines were observed in zones 1 and 7. There was 1 femoral stem revision from periprosthetic fracture 4 years after index surgery and 1 cup revision from aseptic loosening. Kaplan-Meier survivorship with the end point of stem revision for any reason was 98.8% and for aseptic loosening it was 100% at 7 years. Conclusions: The mid-term clinical and radiographic results of the Metha stem in patients with ONFH were promising. Its design enables preservation of the bone stock and the bone trabeculae appear to confirm the assumption of proximal force transmission.


2004 ◽  
Vol 16 (03) ◽  
pp. 133-142 ◽  
Author(s):  
RONG-SEN YANG

Endoprosthetic reconstruction using a custom-made metallic megaendoprosthesis is one of the common modalities for the limb salvage operation. The new promising advance of material science, design and fabrication of the endoprosthesis enable an immediate rehabilitation program and provide a durable and functional limb. Thus a successful limb reconstruction is possible in the well-selected patients. In addition to the endoprosthesis-related increased stress, a limited soft tissue support and constraint after limb salvage procedure usually results in an increased incidence of complications, especially in the long term survivors. Some patients may even need revision of the endoprosthesis and, at times, amputation. The complications after oncological endoprosthectic reconstructions usually occur more frequent than the conventional primary total joint arthroplasty. Considering the characteristics of the surgical procedure and the high demands on the implants, such a relatively high frequency of complications is not unexpected. The common complications include wound necrosis, aseptic loosening, fatigue fracture, local osteolysis, joint contracture, dislodgement/dislocation, nerve or vascular injury, rotational deformity, leg length discrepancy, infection, periprosthectic fracture, etc. Some complications are encountered with other modality of limb salvage procedure, whereas the other endoprosthesis-related complications are endoprosthetic-unique and not uncommon. The major causes of such a relatively high endoprosthesis-related complications include (1) extensive excision of soft tissue, leading to change of biomechanical ergonomics, little soft tissue constraints or support for a long replacement segments, and decreased local defense to infection, (2) increased stress on the implants due to higher activity level in the youthful active individuals, relatively narrower medullary canals with less cancellous bone for fixation, (3) special needs for the stability resulting an increased mechanical constraints placed directly within the endoprosthesis, thus raising the local stress transferred to the prosthesis, and to the prosthesis-bone interface, (4) poor immunological, hematological, or nutritional status resulting from chronic oncologic diseases or chemotherapy. It in turn accelerates the wear processes of the components, induces the wear particulate disease and local osteolysis, as well as to cause the aseptic loosening eventually. Early detection and early correction of minor complications has an important role of preventing the major complications, thus reduces the necessity of reoperation, and at times, amputation. We will review these complications in this article.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
J. Quayle ◽  
A. Barakat ◽  
A. Klasan ◽  
A. Mittal ◽  
G. Chan ◽  
...  

Abstract Background There is little evidence on techniques for management of peri-prosthetic infection (PJI) in the context of severe proximal femoral bone loss. Custom-made articulating spacers (CUMARS) utilising cemented femoral stems as spacers was described providing better bone support and longer survival compared to conventional articulating spacers. We retrospectively report our experience managing PJI by adaptation of this technique using long cemented femoral stems where bone loss precludes use of standard stems. Methods Patients undergoing 1st stage revision for infected primary and revision THA using a cemented long stem (> 205 mm) and standard all-polyethylene acetabulum between 2011 and 2018 were identified. After excluding other causes of revision (fractures or aseptic loosening), Twenty-one patients remained out of total 721 revisions. Medical records were assessed for demographics, initial microbiological and operative treatment, complications, eradication of infection and subsequent operations. 2nd stage revision was undertaken in the presence of pain or subsidence. Results Twenty-one patients underwent 1st stage revision with a cemented long femoral stem. Mean follow up was 3.9 years (range 1.7–7.2). Infection was eradicated in 15 (71.4%) patients. Two patients (9.5%) required repeat 1st stage and subsequently cleared their infection. Three patients (14.3%) had chronic infection and are on long term suppressive antibiotics. One patient (4.8%) was lost to follow up before 2 years. Complications occurred in seven patients (33%) during or after 1st stage revision. Where infection was cleared, 2nd stage revision was undertaken in 12 patients (76.5%) at average of 9 months post 1st stage. Five (23.8%) CUMARS constructs remained in-situ at an average of 3.8 years post-op (range 2.6–5.1). Conclusions Our technique can be used in the most taxing of reconstructive scenarios allowing mobility, local antibiotic delivery, maintenance of leg length and preserves bone and soft tissue, factors not afforded by alternative spacer options.


2021 ◽  
Vol 14 (5) ◽  
pp. e240726
Author(s):  
Giovanni Beltrami ◽  
Anna Maria Nucci ◽  
Angela Tamburini ◽  
Marco Innocenti

Surgical reconstruction after humeral resection represents a challenging issue in orthopaedic oncology. Particularly in paediatric patients, the main concerns are maintaining limb function and reconstruction longevity. We describe a novel strategy of humeral reconstruction based on the use of a three-dimensional-printed custom-made prosthesis in a 13-year-old patient diagnosed with osteosarcoma. The implant was specifically designed to sustain the native head, which was spared, as it was not involved by the neoplastic tissue. The mechanical support the prosthesis provided was associated with the biological stimulus of a free vascularised fibular graft to obtain an anatomic, functional and stable construct. This solution has had good longevity, and after 3 years of follow-up, the patient still shows excellent limb function and personal satisfaction.


2020 ◽  
Author(s):  
Julian Hasler ◽  
Andreas Flury ◽  
Dimitris Dimitriou ◽  
Iris Holweg ◽  
Naeder Helmy ◽  
...  

Abstract Background: There has been an evolution in cementless total hip arthroplasty (THA) with newer short stem designs aim to preserve metaphyseal bone stock and facilitate implantation through minimally invasive approaches. While early subsidence has been correlated to aseptic loosening in conventional stems, there is a paucity of data regarding short stems. The current study aims to report on stem subsidence and midterm clinical outcomes of a cementless, metaphyseal-anchored short femoral stem, specifically designed for the direct anterior approach (DAA).Methods: 94 consecutive patients (100 hips) with a minimum follow-up of 5 years following cementless THA were included in this single-center retrospective study. Subsidence was evaluated using the “Ein-Bild-Roentgen-Analyse” (EBRA). Periprosthetic radiolucency allocated to the Zones of Charnley and Gruen was assessed. Additionally, demographic and implant-related factors potentially associated with increased subsidence and clinical outcomes were evaluated.Results: At the last follow-up, the average stem subsidence was 1.98 ± 1.20 mm, with 48% of the implants demonstrating subsidence of > 2 mm. Periprosthetic radiolucency of > 2 mm was found in 26% of the implants in Zone 1, and in 9% in Zone 7, respectively. Neither the amount of subsidence nor proximal periprosthetic radiolucency was associated with aseptic loosening or worse clinical outcomes. Conclusions: Comparable to other proximally-fixed short stem designs, the highest subsidence was observed within the first 3 months following implantation. No demographic or implant-related factors were found to have a statistically significant influence on stem subsidence. Periprosthetic radiolucency and subsidence of the AMISstem is not correlated with worse clinical outcomes at 5-years follow-up.


Sign in / Sign up

Export Citation Format

Share Document