scholarly journals Left atrial 4D flow cardiovascular magnetic resonance: a reproducibility study in sinus rhythm and atrial fibrillation

2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Marco Spartera ◽  
Guilherme Pessoa-Amorim ◽  
Antonio Stracquadanio ◽  
Adam Von Ende ◽  
Alison Fletcher ◽  
...  

Abstract Background Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows sophisticated quantification of left atrial (LA) blood flow, and could yield novel biomarkers of propensity for intra-cardiac thrombus formation and embolic stroke. As reproducibility is critically important to diagnostic performance, we systematically investigated technical and temporal variation of LA 4D flow in atrial fibrillation (AF) and sinus rhythm (SR). Methods Eighty-six subjects (SR, n = 64; AF, n = 22) with wide-ranging stroke risk (CHA2DS2VASc 0–6) underwent LA 4D flow assessment of peak and mean velocity, vorticity, vortex volume, and stasis. Eighty-five (99%) underwent a second acquisition within the same session, and 74 (86%) also returned at 30 (27–35) days for an interval scan. We assessed variability attributable to manual contouring (intra- and inter-observer), and subject repositioning and reacquisition of data, both within the same session (same-day scan–rescan), and over time (interval scan). Within-subject coefficients of variation (CV) and bootstrapped 95% CIs were calculated and compared. Results Same-day scan–rescan CVs were 6% for peak velocity, 5% for mean velocity, 7% for vorticity, 9% for vortex volume, and 10% for stasis, and were similar between SR and AF subjects (all p > 0.05). Interval-scan variability was similar to same-day scan–rescan variability for peak velocity, vorticity, and vortex volume (all p > 0.05), and higher for stasis and mean velocity (interval scan CVs of 14% and 8%, respectively, both p < 0.05). Longitudinal changes in heart rate and blood pressure at the interval scan in the same subjects were associated with significantly higher variability for LA stasis (p = 0.024), but not for the remaining flow parameters (all p > 0.05). SR subjects showed significantly greater interval-scan variability than AF patients for mean velocity, vortex volume, and stasis (all p < 0.05), but not peak velocity or vorticity (both p > 0.05). Conclusions LA peak velocity and vorticity are the most reproducible and temporally stable novel LA 4D flow biomarkers, and are robust to changes in heart rate, blood pressure, and differences in heart rhythm.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ahmet Demirkiran ◽  
Raquel P. Amier ◽  
Mark B. M. Hofman ◽  
Rob J. van der Geest ◽  
Lourens F. H. J. Robbers ◽  
...  

AbstractThe pathophysiology behind thrombus formation in paroxysmal atrial fibrillation (AF) patients is very complex. This can be due to left atrial (LA) flow changes, remodeling, or both. We investigated differences for cardiovascular magnetic resonance (CMR)-derived LA 4D flow and remodeling characteristics between paroxysmal AF patients and patients without cardiac disease. In this proof-of-concept study, the 4D flow data were acquired in 10 patients with paroxysmal AF (age = 61 ± 8 years) and 5 age/gender matched controls (age = 56 ± 1 years) during sinus rhythm. The following LA and LA appendage flow parameters were obtained: flow velocity (mean, peak), stasis defined as the relative volume with velocities < 10 cm/s, and kinetic energy (KE). Furthermore, LA global strain values were derived from b-SSFP cine images using dedicated CMR feature-tracking software. Even in sinus rhythm, LA mean and peak flow velocities over the entire cardiac cycle were significantly lower in paroxysmal AF patients compared to controls [(13.1 ± 2.4 cm/s vs. 16.7 ± 2.1 cm/s, p = 0.01) and (19.3 ± 4.7 cm/s vs. 26.8 ± 5.5 cm/s, p = 0.02), respectively]. Moreover, paroxysmal AF patients expressed more stasis of blood than controls both in the LA (43.2 ± 10.8% vs. 27.8 ± 7.9%, p = 0.01) and in the LA appendage (73.3 ± 5.7% vs. 52.8 ± 16.2%, p = 0.04). With respect to energetics, paroxysmal AF patients demonstrated lower mean and peak KE values (indexed to maximum LA volume) than controls. No significant differences were observed for LA volume, function, and strain parameters between the groups. Global LA flow dynamics in paroxysmal AF patients appear to be impaired including mean/peak flow velocity, stasis fraction, and KE, partly independent of LA remodeling. This pathophysiological flow pattern may be of clinical value to explain the increased incidence of thromboembolic events in paroxysmal AF patients, in the absence of actual AF or LA remodeling.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S310
Author(s):  
Amanda DiCarlo ◽  
Justin Baraboo ◽  
Mitchell A. Collins ◽  
Maurice Pradella ◽  
Patrick M. McCarthy ◽  
...  

2021 ◽  
Vol 6 ◽  
pp. 73
Author(s):  
Mark T Mills ◽  
Ciaran Grafton-Clarke ◽  
Gareth Williams ◽  
Rebecca C Gosling ◽  
Abdulaziz Al Baraikan ◽  
...  

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. Methods: Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). Results: Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (–4.8, 95% CI –15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI –4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). Conclusions: In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow.


2022 ◽  
Author(s):  
Jan Eckstein ◽  
Hermann Körperich ◽  
Lech Paluszkiewicz ◽  
Wolfgang Burchert ◽  
Misagh Piran

Abstract Left-atrial (LA) strain is the result of complex hemodynamics, increasingly assessed by feature-tracking cardiovascular magnetic resonance (CMR). We investigate the value of multi-parametric regression (MPR) analyses and the influence of the heart rate on LA-strain. As LA-strain data remains limited, CMR-quantified sex- and age-dependent normal values were derived. After following a health assessment questionnaire, 183 healthy volunteers (11-70 years, 97 females, median 32.9±28.3 years) were recruited for LA-strain assessment. LA volumetric data, left ventricular strain, transmitral and pulmonary venous blood flow parameters were utilized to create clusters for MPR analyses for all subjects and heart rate-specific subgroups (range: 60–75 beats-per-minute, N=106). In comparison to the total cohort, subgroups showed no gender differences (p>0.05) for LA reservoir, conduit and booster strains (all: 47.3±12.7%; 29.0±15.5%; 17.6±5.4%) and strain rates (all: 2.1±1.0 s−1; -2.9 ± 1.5 s−1; -2.3 ± 1.0 s−1). MPR analyses identified parameter clusters with large effect size (|R²|≥0.26) for reservoir-, conduit- and booster strain and corresponding active and passive cardiac functional parameters. Increased correlations for the subgroup were found. In contrast to previous studies, heart rate selected subgroups showed no gender differences in LA-strain. MPR analyses improve characterization of LA-strain at selected heart rates.


Sign in / Sign up

Export Citation Format

Share Document