scholarly journals Automated breast ultrasound (ABUS) as a screening tool: initial experience

Author(s):  
Amera Abd Elsalam Mostafa ◽  
Mohamed Adel Eltomey ◽  
Ashraf Mohammed Elaggan ◽  
Amel A. Hashish

Abstract Background Breast cancer is a major health problem, being the most common cancer in women. Early detection of breast cancer aims to the reduction of mortality and morbidity rates. Conventional screening methods include mammography and ultrasonography; however, both modalities have their limitations. Automated breast ultrasound (ABUS) is a recent technological advancement in the field of breast imaging having the benefit of standardization of the scans and lack of operator dependence as in conventional handheld ultrasound scans. The aim of this work was to report our initial experience of the added value of ABUS as a breast screening tool. The study included 200 patients who had screening mammograms, ultrasound, and ABUS. Results A significant difference was found between the number of lesions detected by ABUS and conventional ultrasound. A significant difference was found between lesions detected by ABUS and mammography which was most evident in patients with dense breasts. Conclusions ABUS is a valuable tool in the screening of the breast with improved lesion detection, especially in patients with dense breasts.

Author(s):  
Iris Allajbeu ◽  
Sarah E Hickman ◽  
Nicholas Payne ◽  
Penelope Moyle ◽  
Kathryn Taylor ◽  
...  

Abstract Purpose of Review Automated breast ultrasound (ABUS) is a three-dimensional imaging technique, used as a supplemental screening tool in women with dense breasts. This review considers the technical aspects, pitfalls, and the use of ABUS in screening and clinical practice, together with new developments and future perspectives. Recent Findings ABUS has been approved in the USA and Europe as a screening tool for asymptomatic women with dense breasts in addition to mammography. Supplemental US screening has high sensitivity for cancer detection, especially early-stage invasive cancers, and reduces the frequency of interval cancers. ABUS has similar diagnostic performance to handheld ultrasound (HHUS) and is designed to overcome the drawbacks of operator dependence and poor reproducibility. Concerns with ABUS, like HHUS, include relatively high recall rates and lengthy reading time when compared to mammography. ABUS is a new technique with unique features; therefore, adequate training is required to improve detection and reduce false positives. Computer-aided detection may reduce reading times and improve cancer detection. Other potential applications of ABUS include local staging, treatment response evaluation, breast density assessment, and integration of radiomics. Summary ABUS provides an efficient, reproducible, and comprehensive supplemental imaging technique in breast screening. Developments with computer-aided detection may improve the sensitivity and specificity as well as radiologist confidence and reduce reading times, making this modality acceptable in large volume screening centers.


2016 ◽  
Vol 206 (6) ◽  
pp. 1341-1350 ◽  
Author(s):  
Maryellen L. Giger ◽  
Marc F. Inciardi ◽  
Alexandra Edwards ◽  
John Papaioannou ◽  
Karen Drukker ◽  
...  

2020 ◽  
pp. 030089162093027
Author(s):  
Catherine Depretto ◽  
Alessandro Liguori ◽  
Alessandra Primolevo ◽  
Serena Di Cosimo ◽  
Francesco Cartia ◽  
...  

Purpose: To investigate the agreement between automated breast ultrasound (ABUS) and hand-held ultrasound (HHUS) in surveillance of women with a history of breast cancer in terms of recurrences or new ipsilateral or contralateral breast cancer. Methods: The institutional review board approved this retrospective study and informed consent was waived. From April to June 2016, women with dense breasts undergoing annual surveillance with mammography and HHUS after breast-conserving surgery were offered supplemental ABUS (Invenia). HHUS was performed by a breast radiologist and ABUS by a trained technician. Images were reviewed by 2 breast radiologists. A per-patient BI-RADS category was independently assigned in all cases and categories were dichotomized into negative (1, 2, 3) and positive (4, 5). Cohen κ, McNemar, and Wilcoxon statistics were used. Final pathology was used as reference standard for malignant lesions. Results: A total of 154 women (mean age 62±11 years) were enrolled. Time from surgery was a mean of 8±6 years. Cancer prevalence was 4/154 (2.6%). Interreader agreement for ABUS was 1. Intermethod interreader agreement for HHUS and ABUS was substantial for BI-RADS categories (κ = 0.785) and for dichotomic assessment (κ = 0.794). There was no difference in dichotomic assignment between 2 readers ( p = 0.5) but a significant difference in assigning BI-RADS categories ( p < 0.05). Conclusions: A substantial agreement resulted between HHUS and ABUS in surveillance of women with a previous history of breast cancer. In particular, ABUS recognized all cancers detected by HHUS and could play a role in first-level surveillance of women at intermediate risk.


2016 ◽  
Vol 58 (5) ◽  
pp. 515-520 ◽  
Author(s):  
Roxanna Hellgren ◽  
Paul Dickman ◽  
Karin Leifland ◽  
Ariel Saracco ◽  
Per Hall ◽  
...  

Background Automated breast volume scanner (ABVS) is an ultrasound (US) device with a wide scanner that sweeps over a large area of the breast and the acquired transverse images are sent to a workstation for reconstruction and review. Whether ABVS is as reliable as handheld US is, however, still not established. Purpose To compare the sensitivity and specificity of ABVS to handheld breast US for detection of breast cancer, in the situation of recall after mammography screening. Material and Methods A total of 113 women, five with bilateral suspicious findings, undergoing handheld breast US due to a suspicious mammographic finding in screening, underwent additional ABVS. The methods were assessed for each breast and each detected lesion separately and classified into two categories: breasts with mammographic suspicion of malignancy and breasts with a negative mammogram. Results Twenty-six cancers were found in 25 women. In the category of breasts with a suspicious mammographic finding (n = 118), the sensitivity of both handheld US and ABVS was 88% (22/25). The specificity of handheld US was 93.5% (87/93) and ABVS was 89.2% (83/93). In the category of breasts with a negative mammography (n = 103), the sensitivity of handheld US and ABVS was 100% (1/1). The specificity of handheld US was 100% (102/102) and ABVS was 94.1% (96/102). Conclusion ABVS can potentially replace handheld US in the investigation of women recalled from mammography screening due to a suspicious finding. Due to the small size of our study population, further investigation with larger study populations is necessary before the implementation of such practice.


2019 ◽  
Vol 21 (2) ◽  
pp. 200
Author(s):  
Anca Ileana Ciurea ◽  
Ioana Boca ◽  
Liliana Rogojan ◽  
Larisa Dorina Ciule ◽  
Cristiana Augusta Ciortea

Metastases to the skeletal muscle from breast cancer represent an unusual and rare condition. We present the case of a 27-year-old female with left breast cancer (IDC NST G3) who underwent neoadjuvant chemotherapy followed by conservativesurgery (sectorectomy and lymphadenectomy) and radiation therapy. Two months after the end of radiotherapy she presented with a 2 mm skin lesion and she was referred for a screening ultrasound. The screening automated breast ultrasound (ABUS) revealed local recurrence and pectoralis metastases, lesions evaluated also by magnetic resonance imaging. The diagnosis was confirmed by the ultrasound-guided biopsy.


Sign in / Sign up

Export Citation Format

Share Document