Research on the energy dissipation and stress distribution characteristics of the excavated circular tunnel under high stress conditions

2010 ◽  
pp. 561-565
Author(s):  
S Wang ◽  
H Zhang ◽  
P Liu ◽  
H Jia
2018 ◽  
Vol 38 (3) ◽  
pp. 338-351
Author(s):  
Shunchuan Wu ◽  
Miaofei Xu ◽  
Yongtao Gao ◽  
Shihuai Zhang ◽  
Fan Chen

This paper presents an elastic analytical solution to a circular tunnel with releasing slots at high stress areas near the hole by using a conformal mapping method and the complex variable theory. Compared to the original stress distribution around the circular hole, the releasing effect on elastic stresses is evaluated. After grooving slots, low stress area is generated where the high stress concentration is located. This is agreeable with what was predicted by the finite difference FLAC2D. Besides, displacements are obtained along the periphery of the released hole and are in accordance with those of FLAC2D. In addition to the intersection of the mapping contour, the influences of the sampling points distribution, series number in mapping function, and slot shape are discussed. It is inevitable that the mapping accuracies for the slot and the circle cannot be satisfied at the same time The mapping effect on the circle has to be considered primarily since the stress distribution around the circle is much more significant than the tunnel stability. The analytical solution can be available and fast method of estimating the releasing effect of the application on the tunnel without rock parameters.


Crisis ◽  
2012 ◽  
Vol 33 (2) ◽  
pp. 106-112 ◽  
Author(s):  
Christopher M. Bloom ◽  
Shareen Holly ◽  
Adam M. P. Miller

Background: Historically, the field of self-injury has distinguished between the behaviors exhibited among individuals with a developmental disability (self-injurious behaviors; SIB) and those present within a normative population (nonsuicidal self-injury; NSSI),which typically result as a response to perceived stress. More recently, however, conclusions about NSSI have been drawn from lines of animal research aimed at examining the neurobiological mechanisms of SIB. Despite some functional similarity between SIB and NSSI, no empirical investigation has provided precedent for the application of SIB-targeted animal research as justification for pharmacological interventions in populations demonstrating NSSI. Aims: The present study examined this question directly, by simulating an animal model of SIB in rodents injected with pemoline and systematically manipulating stress conditions in order to monitor rates of self-injury. Methods: Sham controls and experimental animals injected with pemoline (200 mg/kg) were assigned to either a low stress (discriminated positive reinforcement) or high stress (discriminated avoidance) group and compared on the dependent measures of self-inflicted injury prevalence and severity. Results: The manipulation of stress conditions did not impact the rate of self-injury demonstrated by the rats. The results do not support a model of stress-induced SIB in rodents. Conclusions: Current findings provide evidence for caution in the development of pharmacotherapies of NSSI in human populations based on CNS stimulant models. Theoretical implications are discussed with respect to antecedent factors such as preinjury arousal level and environmental stress.


2021 ◽  
pp. 039139882199939
Author(s):  
Abdul Hadi Abdul Wahab ◽  
Nor Aqilah Mohamad Azmi ◽  
Mohammed Rafiq Abdul Kadir ◽  
Amir Putra Md Saad

Glenoid conformity is one of the important aspects that could contribute to implant stability. However, the optimal conformity is still being debated among the researchers. Therefore, this study aims to analyze the stress distribution of the implant and cement in three types of conformity (conform, non-conform, and hybrid) in three load conditions (central, anterior, and posterior). Glenoid implant and cement were reconstructed using Solidwork software and a 3D model of scapula bone was done using MIMICS software. Constant load, 750 N, was applied at the central, anterior, and posterior region of the glenoid implant which represents average load for daily living activities for elder people, including, walking with a stick and standing up from a chair. The results showed that, during center load, an implant with dual conformity (hybrid) showed the best (Max Stress—3.93 MPa) and well-distributed stress as compared to other conformity (Non-conform—7.21 MPa, Conform—9.38 MPa). While, during eccentric load (anterior and posterior), high stress was located at the anterior and posterior region with respect to the load applied. Cement stress for non-conform and hybrid implant recorded less than 5 MPa, which indicates it had a very low risk to have cement microcracks, whilst, conform implant was exposed to microcrack of the cement. In conclusion, hybrid conformity showed a promising result that could compromise between conform and non-conform implant. However, further enhancement is required for hybrid implants when dealing with eccentric load (anterior and posterior).


2013 ◽  
Vol 811 ◽  
pp. 218-222
Author(s):  
Li’an Zhang ◽  
Lei Zhang ◽  
Cao Shi ◽  
Shun Xin Yang

New Generation Large Aircrafts became a new member of China large airports. However, its heavy weight and high contact pressure would have great impact on the flexible runway pavement. in this paper, based on the multilayered elastic theory, the tensile stress distribution under different airplane was studied to obtain the critical load positions. Furthermore, parameter sensitivity analysis was conducted, including thickness and modulus of Asphalt Stabilized Base (ATB) layer. Results indicated that increasing ATB thickness can only decrease the tensile stress a little, and increasing the modulus of the ATB layer will be more efficient than increasing its thickness. Finally pavement design suggestions composing of both the structural and material considerations were proposed.


Sign in / Sign up

Export Citation Format

Share Document