Design Standards

2021 ◽  
pp. 13-36
Author(s):  
Sandipan Goswami ◽  
Pradip Sarkar
Keyword(s):  
2020 ◽  
Vol 0 (6) ◽  
pp. 119-134
Author(s):  
Denis Mykhaylovskyi ◽  
Bohdan Bondarchuk

Author(s):  
Thierry Brenac

This paper deals with safety at horizontal curves on two-lane roads outside urban areas and the way the road design standards of different European countries account for this safety aspect. After a review of some research results, the main aspects of curve geometry and the curve's place in the horizontal alignment are analyzed. The main conclusions are that the traditional design speed approach is insufficient and that formal complementary rules in road design standards, especially to improve compatibility between successive elements of the alignment, must be introduced. If such complementary rules already exist in some national standards, they are neither frequent nor homogeneous throughout the different countries, and it seems that they are not based on sufficiently developed knowledge.


2021 ◽  
pp. 073490412110301
Author(s):  
Yawei Wang ◽  
Gaowan Zou ◽  
Conglin Liu ◽  
Y Gao

The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.


1989 ◽  
Vol 16 (2) ◽  
pp. 124-139 ◽  
Author(s):  
Robert G. Driver ◽  
D. J. Laurie Kennedy

Design standards provide little information for the design of I-shaped steel beams not loaded through the shear centre and therefore subjected to combined flexure and torsion. In particular, methods for determining the ultimate capacity, as is required in limit states design standards, are not presented. The literature on elastic analysis is extensive, but only limited experimental and analytical work has been conducted in the inelastic region. No comprehensive design procedures, applicable to limit states design standards, have been developed.From four tests conducted on cantilever beams, with varying moment–torque ratios, it is established that the torsional behaviour has two distinct phases, with the second dominated by second-order geometric effects. This second phase is nonutilizable because the added torsional restraint developed is path dependent and, if deflections had been restricted, would not have been significant. Based on the first-phase behaviour, a normal and shearing stress distribution on the cross section is proposed. From this, a moment–torque ultimate strength interaction diagram is developed, applicable to a number of different end and loading conditions. This ultimate limit state interaction diagram and serviceability limit states, based on first yield and on distortion limitations, provide a comprehensive design approach for these members. Key words: beams, bending moment, flexure, inelastic, interaction diagram, I-shaped, limit states, serviceability, steel, torsion, torque, ultimate.


1993 ◽  
Vol 7 (2) ◽  
pp. 218-237 ◽  
Author(s):  
Nobuyoshi Yabuki ◽  
Kincho H. Law
Keyword(s):  

2011 ◽  
Vol 243-249 ◽  
pp. 4905-4908
Author(s):  
Xue Min Sui ◽  
Xu Zhang ◽  
Guang Hui Han

Relative humidity is an important micro-climate parameter in radiant cooling environment. Based on the human thermal comfort model, this paper studied the effect on PMV index of relative humidity, and studied the relationship of low mean radiant temperature and relative humidity, drew the appropriate design range of indoor relative humidity for radiant cooling systems.The results show that high relative humidity can compensate for the impact on thermal comfort of low mean radiant temperature, on the premise of achieving the same thermal comfort requirements. However, because of the limited compensation range of relative humidity, together with the constraints for it due to anti-condensation of radiant terminal devices, the design range of relative humidity should not be improved, and it can still use the traditional air-conditioning design standards.


Author(s):  
Abdelfettah Fredj ◽  
Aaron Dinovitzer

Pipeline integrity is affected by the action of external soil loads in addition to internal fluid pressure. External soil loads can be generated by landslides or at sites subject to ground subsidence, heave or seismic effects. Under these varied conditions of ground movement potential pipeline safety involves constraints on design and operations. The design processes includes developing an understanding of strains that could be imposed on the pipe (strain demand) and strain limits that the pipe can withstand without failure. The ability to predict the pipeline load, stress or strains state in the presence of soil restraint and/or soil displacement induced loading is not well described in design standards or codes of practice. This paper describes the ongoing work involved in a study investigating the mechanical behavior of buried pipelines interacting with active landslides. Detailed pipe-soil interaction analyses were completed with a 3D continuum SPH method. This paper describes the LS-DYNA numerical modeling process, previously developed by the authors, which was refined and applied to site-specific conditions. To illustrate the performance of the modeling process to consider a translational slide, additional numerical model validation was completed and is described in this paper. These comparisons illustrate that good agreement was observed between the modeling results and experimental full scale trial results. Sample results of the application of the validated 3D continuum modeling process are presented. These results are being used to develop generalized trends in pipeline response to slope movements. The paper describes both the progress achieved to date and the future potential for simplified engineering design tools to assess the load or deformation capacity requirements of buried pipelines exposed to different types of slope movement.


Sign in / Sign up

Export Citation Format

Share Document