Experimental study of hysteretic energy absorption and load capacity of reinforced concrete columns subjected to different cyclic loading rates

1991 ◽  
pp. 287-296
2016 ◽  
Vol 9 (5) ◽  
pp. 796-823
Author(s):  
A. C. MESQUITA ◽  
A. S. ROCHA ◽  
R. G. DELALIBERA ◽  
W. A. DA SILVA

Abstract This article presents a columns reinforcement experimental study, with the use of anchor steel bolts and fill with self-compacting concrete. Were tested five columns of reinforced concrete subjected to flexion-compression: two columns were used as reference, and a cross-section equal to 120 x 250 mm; with a monolithic section equal to 155 x 250 mm cross section of the same reinforced columns and three which were initially molded with a 120 x 250 mm section and subsequently received a layer of 35 mm thick self-compacting concrete in the compressed side. Despite the studs do not present break, there was peeling of the reinforcement layer. The results indicate the possibility of using this method in reinforcing structural rehabilitation of reinforced concrete columns, with increase in load capacity on average equal to 403% in relation to the column reference.


2017 ◽  
Vol 27 (9) ◽  
pp. 1416-1447 ◽  
Author(s):  
Liu Jin ◽  
Shuai Zhang ◽  
Dong Li ◽  
Haibin Xu ◽  
Xiuli Du ◽  
...  

The results of an experimental program on eight short reinforced concrete columns having different structural sizes and axial compression ratios subjected to monotonic/cyclic lateral loading were reported. A 3D mesoscopic simulation method for the analysis of mechanical properties of reinforced concrete members was established, and then it was utilized as an important supplement and extension of the traditional experimental method. Lots of numerical trials, based on the restricted experimental results and the proposed 3D mesoscopic simulation method, were carried out to sufficiently evaluate the seismic performances of short reinforced concrete columns with different structural sizes and axial compression ratios. The test results indicate that (1) the failure pattern of reinforced concrete columns can be significantly affected by the shear-span ratio; (2) increasing the axial compression ratio could improve the load capacity of the reinforced concrete column, but the deformation capacity would be restricted and the failure mode would be more brittle, consequently the energy dissipation capacity could be deteriorated; and (3) the load capacity, the displacement ductility, and the energy dissipation capacity of the short reinforced concrete columns all exhibit clear size effect, namely, the size effect could significantly affect the seismic behavior of reinforced concrete columns.


2018 ◽  
Vol 183 ◽  
pp. 02008 ◽  
Author(s):  
Pavlo Krainskyi ◽  
Yaroslav Blikharskyy ◽  
Roman Khmil ◽  
Zinoviy Blikharskyy

The need of structural retrofitting and strengthening of different buildings, engineering structures or their elements is always present. Among the main reasons are demages and material deterioration due to aging, improper maintenance or physical damages; planed repairs; reconstruction or extension of the building; technical modification or complete change of operations inside the building or the structure, etc. In some cases operation of the building during retrofitting or strengthening of its structures has to be partially or fully stopped. In other cases the strengthening process takes place while the building is still operational which means that structures are strengthened under service loads. The main goal of this research is to determine the strengthening effect of reinforced concrete jacketing applied to columns under service load level. For that the experimental study of six reinforced concrete columns were carried out: four reference columns, both strengthened by jacketing and unstrengthened and two strengthened under service load. The main results of the research are presented.


2010 ◽  
Vol 163-167 ◽  
pp. 2267-2273 ◽  
Author(s):  
Hong Ying Dong ◽  
Wan Lin Cao ◽  
Jian Wei Zhang

Two 1/6 scale core walls, including one RC core wall with steel tube-reinforced concrete columns and concealed steel trusses and one conventional RC core wall, were tested under eccentric horizontal cyclic loading. The load-capacity, ductility, hysteresis characteristics, stiffness, stiffness deterioration process, energy dissipation and damage characteristics of the two specimens were compared and discussed in this paper. It shows that the seismic performance of the RC core walls under combined action could be improved by setting the concealed steel trusses in the walls and using the steel tube-reinforced concrete columns as the boundary elements.