scholarly journals Comparison of the Safety and Efficacy of Automated Annotation-Guided Radiofrequency Ablation and 2nd-Generation Cryoballoon Ablation in Paroxysmal Atrial Fibrillation

2019 ◽  
Vol 83 (3) ◽  
pp. 548-555 ◽  
Author(s):  
Nobuaki Tanaka ◽  
Koji Tanaka ◽  
Yuichi Ninomiya ◽  
Yuko Hirao ◽  
Takafumi Oka ◽  
...  
QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p < 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.


2021 ◽  
Vol 27 (4) ◽  
pp. 12-16
Author(s):  
E. B. Kropotkin ◽  
E. A. Ivanitskiy ◽  
D. A. Shlyakov ◽  
Yu. V. Ivanitskaya ◽  
V. A. Sakovich

To assess safety and efficacy of nonfluoroscopic cryoballoon ablation, 32 patients with symptomatic drug resistant paroxysmal atrial fibrillation were treated.


2016 ◽  
Vol 157 (22) ◽  
pp. 849-854 ◽  
Author(s):  
Zsófia Nagy ◽  
Zsuzsanna Kis ◽  
Zoltán Som ◽  
Csaba Földesi ◽  
Attila Kardos

Introduction: Contact force sensing radiofrequency ablation and the new generation cryoballoon ablation are prevalent techniques for the treatment of paroxysmal atrial fibrillation. Aim: The authors aimed to compare the procedural and 1-year outcome of patients after radiofrequency and cryoballoon ablation. Method: 96 patients with paroxysmal atrial fibrillation (radiofrequency ablation: 58, cryoballoon: 38 patients; 65 men and 31 women aged 28–70 years) were enrolled. At postprocedural 1, 3, 6 and 12 months ECG, Holter monitoring and telephone interviews were performed. Results: Procedure and fluorosocopy time were: radiofrequency ablation, 118.5 ± 15 min and 15.8 ± 6 min; cryoballoon, 73.5 ± 16 min (p<0.05) and 13.8 ± 4.,1 min (p = 0.09), respectively. One year later freedom from atrial fibrillation was achieved in 76.5% of patients who underwent radiofrequency ablation and in 81% of patients treated with cryoballoon. Temporary phrenic nerve palsy occurred in two patients and pericardial tamponade developed in one patient. Conclusions: In this single center study freedom from paroxysmal atrial fibrillation was similar in the two groups with significant shorter procedure time in the cryoballoon group. Orv. Hetil., 2016, 157(22), 849–854.


2020 ◽  
Vol 8 (B) ◽  
pp. 563-568
Author(s):  
Walid Shehata Hassan ◽  
Sherief Hamed Zaky ◽  
Khaled Hussein Mohamed ◽  
Moataz Mohammed Ibrahim

AIM: Evaluation of the safety and efficacy of pulmonary veins isolation in patients with paroxysmal atrial fibrillation (AF) using two new different technologies, cryoballoon (CB) ablation and radiofrequency ablation with contact force (CF)-sensing catheters. METHODS: Prospective single-center evaluation, carried out from January 2016 to June 2018 in Critical Care Medicine Department – Cairo University, comparing CF radiofrequency (Thermocool® SmartTouch, Biosense Webster, Inc.) (CF group) with CB ablation (Arctic Front Advance 28 mm CB, Medtronic, Inc.) (CB group), in regards to procedural safety and efficacy, as well as recurrence at 12 months. Overall, 50 consecutive patients were enrolled (25 in each group). RESULTS: The characteristics of patients of both the groups were similar (46.9 ± 11.2 years, the proportion of women 36%, mean documented AF duration 3 ± 2.3 years, mean CHA2DS2-VASc score 1.4 ± 1.3, and mean HAS-BLED 1.4 ± 0.6). Duration of the procedure was significantly lower in the CB group (171.7 ± 15.24 vs. 199.3 ± 18.94 min, p = 0.002), with a longer duration of fluoroscopy and X-ray exposure in the CB group than the CF group but statistically non-significant difference (58.60 ± 11.57 vs. 48.7 ± 13.86 min and 6273 ± 4934 cGy cm² vs. 6853 ± 5069 cGy cm², p = 0.1 and p = 0.2, respectively). Overall complication rate was similar in both groups: 2 (8%) in each group. At 12 months, AF recurrence occurred in 7 patients (28%) in the CF group and in 9 patients (36%) in the CB group (log rank p = 0.682). CONCLUSION: Pulmonary vein isolation using CF-guided RF and second-generation CB leads to comparable single-procedure arrhythmia-free survival at up to 12 months with similar overall complication rate.


EP Europace ◽  
2016 ◽  
Vol 18 (suppl_1) ◽  
pp. i122-i122
Author(s):  
Bradley Knight ◽  
Paul Novak ◽  
Robert Sangrigoli ◽  
Jean Champagne ◽  
Marc Dubuc ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document