Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.

2019 ◽  
Vol 101-B (6_Supple_B) ◽  
pp. 45-50 ◽  
Author(s):  
D. T. Schloemann ◽  
A. I. Edelstein ◽  
R. L. Barrack

Aims The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position. Patients and Methods We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (sd 10.7) and the mean body mass index (BMI) was 20.0 kg/m2 (sd 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant. Results Intraoperatively, in the lateral decubitus position, the pelvic ratio increased (anterior tilt) in 69.4% of cases, did not change significantly in 20.4%, and decreased (posterior tilt) in 10.2% of cases. When six-week postoperative radiographs were compared with preoperative radiographs, the pelvic ratio decreased in 44.9% of cases, did not change significantly in 42.3%, and increased in 12.8% of cases. This change in alignment correlated with a change in acetabular component version of > 5° in 79.6% of cases intraoperatively and 57.7% of cases at six weeks postoperatively. Conclusion Changes in pelvic sagittal pelvic position occur throughout THA that, if unaccounted for, introduce errors in acetabular component placement. The use of intraoperative imaging may help the appropriate placement of the acetabular component. Cite this article: Bone Joint J 2019;101-B(6 Supple B):45–50.


2003 ◽  
Vol 44 (1) ◽  
pp. 84-91 ◽  
Author(s):  
H. Olivecrona ◽  
L. Weidenhielm ◽  
L. Olivecrona ◽  
M. E. Noz ◽  
G. Q Maguire ◽  
...  

2003 ◽  
Vol 44 (4) ◽  
pp. 419-429 ◽  
Author(s):  
L. Olivecrona ◽  
H. Olivecrona ◽  
L. Weidenhielm ◽  
M. E. Noz ◽  
G. Q. Maguire ◽  
...  

Purpose: Validation of a non-invasive CT method for detection of acetabular cup migration after total hip arthroplasty in a phantom study. Material and Methods: 26 CT examinations were obtained of a pelvic model while altering the position of the acetabular cup. Using a previously described program for volume merging, the pelvi in different examinations were fused and the 3D alterations of the position of the acetabular cup were evaluated visually and numerically and correlated to direct measurements on the model. Results: Visually, two independent examiners differentiated between 0, 1 and 2 to 3 mm migration with 100% specificity and sensitivity. Numerically, the mean error over all cases between model and CT measurements was 0.04 mm (SD ± 0.33). The mean absolute error between model and CT data was 0.26 mm (SD ± 0.19). Intra- and interobserver 95% accuracy and repeatability limits were below 0.5/0.7 mm, respectively. No significant interobserver difference occurred. The data were normally distributed and not dependent on observer. Conclusion: The accuracy of this non-invasive method out-performs routine plain radiography. The method gives both visual and numerical correlates to migration and can be used in clinical practice.


Symmetry ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1472
Author(s):  
Krystian Kazubski ◽  
Łukasz Tomczyk ◽  
Mariusz Ciszewski ◽  
Jarosław Witkowski ◽  
Paweł Reichert ◽  
...  

Background: Approximately 10–25% of total hip replacement patients undergo a bilateral procedure. The purpose of this study was to compare selected parameters associated with the first and second hip arthroplasty in patients undergoing two-stage treatment due to bilateral hip osteoarthritis and establish the predictive factors for the second procedure. Methods: This study compared the data on bilateral total hip replacement surgeries conducted in the period between 2017 and 2021 (42 patients). The following parameters from the first and second procedure were compared: the prosthetic stem, head, and insert cup size; type of cup insert; duration of anesthesia; duration of hospitalization; and the number of complications. Results: The mean duration of hospital stay at the time of the first total hip arthroplasty was 5.83 days and 5.4 days during the second stay. The mean stem sizes used during the first and second total hip replacement procedures were 7.11 and 7.09, respectively. The mean sizes of endoprosthetic cups used at the first and second total hip replacement procedures were 52.64 and 53.04, respectively. There were no significant differences between the mean prosthetic head size at the first and second surgery. The cup type used during the first and second surgery showed no difference. The mean duration of anesthesia used during the first and second total hip replacement surgery was 108.09 min and 104.52 min, respectively. We recorded a mean of 0.07 complications per patient at the first surgery and 0.02 at the second surgery. Conclusions: Our study results showed symmetry duration of anesthesia, length of hospital stay, number of complications per patient, stem size, prosthetic head size, cup insert size, and cup insert type at the first and second surgery in patients with two-stage bilateral total hip arthroplasty. We observed a strong correlation between the stem sizes of the first and second hip endoprostheses. There was also a strong correlation between the cup sizes used during the first and second surgery.


2021 ◽  
Vol 11 (15) ◽  
pp. 6853
Author(s):  
Filippo Migliorini ◽  
Lucio Cipollaro ◽  
Francesco Cuozzo ◽  
Francesco Oliva ◽  
Andrea Valerio Marino ◽  
...  

Introduction: Outpatient total hip arthroplasty (THA) is increasingly popular. This meta-analysis investigated the potential advantages of outpatient regimes for THA. Methods: This study followed the PRISMA guidelines. PubMed, Web of Science, Google Scholar, Embase, and Scopus databases were accessed in June 2021. All clinical studies investigating outpatient THA were considered. The outcomes of interest were pain, infection, mortality, revision, dislocation, readmission rates, and deep vein thrombosis (DVT). Results: Data from 102,839 patients were included. A total of 52% (153,168 of 102,839 patients) were women. The mean age of patients was 62.6 ± 4.6 years, the mean BMI was 29.1 ± 1.8 kg/m2. Good comparability was found in age, BMI, and gender (p > 0.1). No difference was found in pain (p = 0.4), infections (p = 0.9), mortality (p = 0.9), rate of revision (p = 0.1), dislocation (p = 0.9), and readmission (p = 0.8). The outpatient group demonstrated a greater rate of DVT (OR 3.57; 95% CI 2.47 to 5.18; p < 0.0001). Conclusions: In selected patients, outpatient THA can be performed safely with optimal outcomes comparable with inpatient THA. Clear and comprehensive pre-operative planning should involve a multi-disciplinary group composed of orthopaedic surgeons, anaesthesia and rehabilitation specialists, and physiotherapists. Each centre performing outpatient THA should implement continuous homecoming welfare activity, to supervise physiotherapy and monitor anticoagulant therapy.


Author(s):  
Andrew G. Yun ◽  
Marilena Qutami ◽  
Kory B. Dylan Pasko

AbstractPreoperative templating for total hip arthroplasty (THA) is fraught with uncertainty. Specifically, the conventional measurement of the lesser trochanter to the center (LTC) of the femoral head used in preoperative planning is easily measured on a template but not measurable intraoperatively. The purpose of this study was to examine the utility of a novel measurement that is reproducible both on templating and in surgery as a more accurate and practical guide. We retrospectively reviewed 201 patients with a history of osteoarthritis who underwent primary THA. For preoperative templating, the distance from the top of the lesser trochanter to the equator (LeTE) of the femoral head was measured on a calibrated digital radiograph with a neutral pelvis. This measurement was used intraoperatively to guide the choice of the trial neck and head. As with any templating technique, the goal was to construct a stable, impingement-free THA with equivalent leg lengths and hip offset. In evaluating this novel templating technique, the primary outcomes measured were the number of trial reductions and the amount of fluoroscopic time, exposures, and radiation required to obtain a balanced THA reconstruction. Using the LeTE measurement, the mean number of trial reductions was 1.21, the mean number of intraoperative fluoroscopy images taken was 2.63, the mean dose of radiation exposure from fluoroscopy was 0.02 mGy, and the mean fluoroscopy time per procedure was 0.6 seconds. In hips templated with the conventional LTC prior to the LeTE, the mean fluoroscopy time was 0.9 seconds. There was a statistically significant difference in fluoroscopy time (p < 0.001). The LeTE is a reproducible measurement that transfers reliably from digital templating to surgery. This novel preoperative templating metric reduces the fluoroscopy time and consequent radiation exposure to the surgical team and may minimize the number of trial reductions.


Author(s):  
Jesus M. Villa ◽  
Tejbir S. Pannu ◽  
Carlos A. Higuera ◽  
Juan C. Suarez ◽  
Preetesh D. Patel ◽  
...  

AbstractHospital adverse events remain a significant issue; even “minor events” may lead to increased costs. However, to the best of our knowledge, no previous investigation has compared perioperative events between the first and second hip in staged bilateral total hip arthroplasty (THA). In the current study, we perform such a comparison. A retrospective chart review was performed on a consecutive series of 172 patients (344 hips) who underwent staged bilateral THAs performed by two surgeons at a single institution (2010–2016). Based on chronological order of the staged arthroplasties, two groups were set apart: first-staged THA and second-staged THA. Baseline-demographics, length of stay (LOS), discharge disposition, hospital adverse events, and hospital transfusions were compared between groups. Statistical analyses were performed using independent t-tests, Fisher's exact test, and/or Pearson's chi-squared test. The mean time between staged surgeries was 465 days. There were no significant differences in baseline demographics between first-staged THA and second-staged THA groups (patients were their own controls). The mean LOS was significantly longer in the first-staged THA group than in the second (2.2 vs. 1.8 days; p < 0.001). Discharge (proportion) to a facility other than home was noticeably higher in the first-staged THA group, although not statistically significant (11.0 vs. 7.6%; p = 0.354). The rate of hospital adverse events in the first-staged THA group was almost twice that of the second (37.2 vs. 20.3%; p = 0.001). There were no significant differences in transfusion rates. However, these were consistently better in the second-staged THA group. When compared with the first THA, our findings suggest overall shorter LOS and fewer hospital adverse events following the second. Level of Evidence Level III.


2017 ◽  
Vol 9 (2) ◽  
Author(s):  
Afshin Taheriazam ◽  
Amin Saeidinia

Total hip arthroplasty (THA) is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA) has a large number of advantages, although there are concerns about the higher complications in this procedure. Aim of our study was to evaluate the complications and outcomes of cementless one-stage BTHA in osteoarthritis patients. A total of 147 patients from 2009 till 2012, underwent one-stage BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with osteoarthritis was performed. We evaluated all patients clinically and radiologically with serial followups. A clinical hip score based upon the modified Harris Hip Score (MHHS) was performed preoperatively and again postoperatively. During the period of study 89 men (60.5%) and 58 women (39.4%) with a mean age of 54.67±7.08 years at the time of presentation were recruited. The mean surgical time was 2.8±0.25 hrs. The mean hospital stay was 3.83±0.65 days. Hemoglobin level decreased significantly after operation (P=0.038). There was two deep venous thromboses, one superficial infection and one temporal proneal palsy but no pulmonary embolism, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 41.64±5.42 in patients. MHHS score improved to 89.26±4.68 in the last followup (P=0.0001). Our results recommended the use of cementless one-stage BTHA through Hardinge approach in patients with bilateral hip osteoarthritis.


2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.


2020 ◽  
Author(s):  
Yinqiao Du ◽  
Jingyang Sun ◽  
Haiyang Ma ◽  
Sen Wang ◽  
Ming Ni ◽  
...  

Abstract Background: The purpose of this study was to explore that how to equalize the leg length in total hip arthroplasty (THA) with shortening subtrochanteric osteotomy (SSTO) or not for unilateral Crowe type IV developmental dysplasia of the hip (DDH) through the evaluation of the postoperative full-length anteroposterior radiographs. Methods: The postoperative radiographs of 60 patients with unilateral Crowe type IV DDH from July 2012 to May 2019 were retrospectively reviewed. These data included leg length, femoral length, height of center of rotation (COR) of hip, height of greater trochanter, and depth of the sleeve or cone. Patients with leg length discrepancy (LLD) < 10 mm were defined as the non-LLD group. Results: In the non LLD group (26 patients of SSTO and 22 of non-SSTO), the femoral length both SSTO and non-SSTO groups were significantly shorter on operated side, compared with the contralateral side, and the mean discrepancy in SSTO group was approximately equal to the mean length of SSTO. The mean height of COR of hip on operated sides both SSTO and non-SSTO groups were 13.2 mm, and the contralateral sides were 15.2 mm and 15.5 mm, respectively. The depth of the sleeve or cone between SSTO and non-SSTO groups were 21.7 mm and 30.6 mm, respectively. The depth of the sleeve or cone in SSTO group was negatively correlated with the length of SSTO. The height of the greater trochanter of the operated and contralateral sides were 5.3 mm and 16.6 mm in SSTO group, and those in the non-SSTO group were 13.2 mm and 17.2 mm. Conclusions: SSTO leaded to femoral shortening on the operated side for patients with unilateral Crowe type IV DDH. The position of sleeve or cone should be close to the apex of greater trochanter to compensate the lengh of SSTO.