scholarly journals Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT

2019 ◽  
Vol 92 (1103) ◽  
pp. 20180909 ◽  
Author(s):  
Hui Tang ◽  
Zhentang Liu ◽  
Zhijun Hu ◽  
Taiping He ◽  
Dou Li ◽  
...  

Objective: To evaluate the clinical value of low-dose chest CT combined with the new generation adaptive statistical iterative reconstruction (ASIR-V) algorithm in the diagnosis of pulmonary nodule. Methods: 30 patients with pulmonary nodules underwent chest CT using Revolution CT. The patients were first scanned with standard-dose at a noise index (NI) of 14, and the images were reconstructed with filtered back projection (FBP) algorithm. If pulmonary nodules were found, a low-dose targeted scan, with NI of 24, was performed localized on the nodules, and the images were reconstructed with 60% ASIR-V. The detection rate of pulmonary nodules in the two scanning modes was recorded. The size of nodules, CT value and standard deviation of nodules were measured. The signal-to-noise ratio and contrast-to-noise ratio were also calculated. Two experienced radiologists used a 5-point method to score the image quality. The volumetric CT dose index, and dose–length product were recorded and the effective dose (ED) was calculated of the two scanning modes. Results: Volumetric CT dose index (ED) of the standard-dose scan covering the entire lungs was 7.29 ± 2.38 mGy (3.52 ± 1.09 mSv), and that of low-dose targeted scan was 2.56 ± 1.87 mGy (0.51 ± 0.32 mSv). However, the ED of the virtual low-dose scan for the entire lungs was 1.44 ± 0.15 mSv, which would mean a dose reduction of 59.1% compared with the standard-dose scan. 85 of the 87 pulmonary nodules were detected in the low-dose targeted scan, with 2 of the ground-glass density nodules with size less than 1 cm missed, resulting in 97.7% overall detection rate. There was no difference between the low-dose ASIR-V images and standard-dose FBP images for the size (1.49 ± 0.74 cm vs 1.48 ± 0.75 cm), CT value [33.02 ± 1.95 Hounsfield unit (HU) vs 34.6 ± 3.07 HU], standard deviation (27.64 ± 14.42 HU vs 30.38 ± 20.04 HU), signal-to-noise ratio (1.44 ± 0.88 vs 1.43 ± 1.31) and contrast-to-noise ratio (38.95 ± 18.43 vs 38.23 ± 14.99) of nodules (all p > 0.05). There was no difference in the subjective scores between the two scanning modes. Conclusion: The low-dose CT scan combined with ASIR-V algorithm is of comparable value in the detection and the display of pulmonary nodules when compared with the FBP images obtained by standard-dose scan. Advances in knowledge: This is a clinical study to evaluate the clinical value of pulmonary nodules using ASIR-V algorithm in the same patients in the low-dose chest CT scans. It suggests that ASIR-V provides similar image quality and detection rate for pulmonary nodules at much reduced radiation dose.

2004 ◽  
Vol 15 (1) ◽  
pp. 14-22 ◽  
Author(s):  
Dag Wormanns ◽  
Karl Ludwig ◽  
Florian Beyer ◽  
Walter Heindel ◽  
Stefan Diederich

2019 ◽  
Vol 92 (1103) ◽  
pp. 20190302 ◽  
Author(s):  
Federico Pineda ◽  
Deepa Sheth ◽  
Hiroyuki Abe ◽  
Milica Medved ◽  
Gregory S Karczmar

Objectives: To compare a low-dose dynamic contrast-enhanced breast MRI protocol (LITE MRI) to standard-dosage using a dual-dose injection technique. Methods: 8 females with a total of 10 lesions with imaging features compatible with fibroadenoma were imaged using a dual-dose dynamic contrast-enhanced-MRI (DCE-MRI) technique. After pre-contrast scans, 15% of a standard dose of contrast was administered; approximately 10 min later, the remaining 85% of the standard dose was administered. Enhancement kinetic parameters, conspicuity and signal-to-noise ratio were measured quantitatively. Results: One lesion showed no enhancement in either DCE series. All nine of the enhancing lesions were visualized in both the low-dose and standard-dose images. While the (low-to-standard) ratio of contrast doses was roughly 0.18, this did not match the ratios of kinetic parameters. Lesion conspicuity and enhancement rate were both higher in the low-dose images, with (low-to-standard) ratios 1.5 ± 0.1 and 1.2 ± 0.4, respectively. The upper limit of enhancement (ratio 0.3 ± 0.1) and signal-to-noise ratio (ratio 0.5 ± 0.1) were higher in the standard-dose images, but less than expected based on the ratio of the doses. Conclusions: This preliminary study demonstrates that LITE MRI has the potential to match standard DCE-MRI in the detection of enhancing lesions. Additionally, LITE MRI may enhance sensitivity to contrast media dynamics. Advances in knowledge: Lower doses of MRI contrast media may be equally effective in the detection of breast lesions, and increase sensitivity to contrast media dynamics. LITE MRI may help increase screening compliance and long-term patient safety.


2016 ◽  
Vol 7 (2) ◽  
pp. 381 ◽  
Author(s):  
Lukas B. Gromann ◽  
Dirk Bequé ◽  
Kai Scherer ◽  
Konstantin Willer ◽  
Lorenz Birnbacher ◽  
...  

2021 ◽  
Author(s):  
Wei Zhang ◽  
Baoqiang Xiang ◽  
Ben Kirtman ◽  
Emily Becker

<p>One of the emerging topics in climate prediction is the issue of the so-called “signal-to-noise paradox”, characterized by too small signal-to-noise ratio in current model predictions that cannot reproduce the realistic signal. Recent studies have suggested that seasonal-to-decadal climate can be more predictable than ever expected due to the paradox. But no studies, to the best of our knowledge, have been focused on whether the signal-to-noise paradox exists in subseasonal predictions. The present study seeks to address the existence of the paradox in subseasonal predictions based on (i) coupled model simulations participating in phase 5 and phase 6 of the Coupled Model Intercomparison Project (CMIP5 and CMIP6, respectively), and (ii) subseasonal hindcast outputs from the Subseasonal Experiment (SubX) and the Subseasonal-to-Seasonal Prediction (S2S) projects. Of particular interest is the possible existence of the paradox in the new generation of GFDL SPEAR model, through the diagnosis of which may help identify potential issues in the new forecast system to guide future model development and initialization. Here we investigate the paradox issue using two methods: the ratio of predictable component defined as the ratio of predictable component in the real world to the signal-to-noise ratio in models and the persistence/dispersion characteristics estimated from a Markov model framework. The preliminary results suggest a potentially widespread occurrence of the signal-to-noise paradox in subseasonal predictions, further implying some room for improvement in future ensemble-based subseasonal predictions.</p>


The Analyst ◽  
2016 ◽  
Vol 141 (12) ◽  
pp. 3601-3620 ◽  
Author(s):  
Chengli Wang ◽  
Xiaomin Li ◽  
Fan Zhang

Upconversion nanoparticles (UCNPs), which can emit ultraviolet/visible (UV/Vis) light under near-infrared (NIR) excitation, are regarded as a new generation of nanoprobes because of their unique optical properties, including a virtually zero auto-fluorescence background for the improved signal-to-noise ratio, narrow emission bandwidths and high resistance to photo-bleaching.


2021 ◽  
Vol 18 (5) ◽  
pp. 6771-6789
Author(s):  
Hongyan Xu ◽  

<abstract> <p>With the rapid development of computer technology and network communication technology, copyright protection caused by widely spread digital media has become the focus of attention in various fields. For digital media watermarking technology research emerge in endlessly, but the results are not ideal. In order to better realize the copyright identification and protection, based on the embedded intelligent edge computing detection technology, this paper studies the zero watermark copyright protection algorithm of digital media. Firstly, this paper designs an embedded intelligent edge detection module based on Sobel operator, including image line buffer module, convolution calculation module and threshold processing module. Then, based on the embedded intelligent edge detection module, the Arnold transform of image scrambling technology is used to preprocess the watermark, and finally a zero watermark copyright protection algorithm is constructed. At the same time, the robustness of the proposed algorithm is tested. The image is subjected to different proportion of clipping and scaling attacks, different types of noise, sharpening and blur attacks, and the detection rate and signal-to-noise ratio of each algorithm are calculated respectively. The performance of the watermark image processed by this algorithm is evaluated subjectively and objectively. Experimental data show that the detection rate of our algorithm is the highest, which is 0.89. In scaling attack, the performance of our algorithm is slightly lower than that of Fourier transform domain algorithm, but it is better than the other two algorithms. The Signal to Noise Ratio of the algorithm is 36.854% in P6 multiplicative noise attack, 39.638% in P8 sharpening edge attack and 41.285% in fuzzy attack. This shows that the algorithm is robust to conventional attacks. The subjective evaluation of 33% and 39% of the images is 5 and 4. The mean values of signal to noise ratio, peak signal to noise ratio, mean square error and mean absolute difference are 20.56, 25.13, 37.03 and 27.64, respectively. This shows that the watermark image processed by this algorithm has high quality. Therefore, the digital media zero watermark copyright protection algorithm based on embedded intelligent edge computing detection is more robust, and its watermark invisibility is also very superior, which is worth promoting.</p> </abstract>


Sign in / Sign up

Export Citation Format

Share Document