scholarly journals Three-Year Exploitation Tests of a Photovoltaic Plant in a Zero-Energy Single-Family House under the Polish Conditions

2020 ◽  
Vol 21 (7) ◽  
pp. 160-168
Author(s):  
Kazimierz Gaj
Buildings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 364
Author(s):  
Johannes Koke ◽  
André Schippmann ◽  
Jingchun Shen ◽  
Xingxing Zhang ◽  
Peter Kaufmann ◽  
...  

Container-based lightweight buildings offer a high ecologic and economic potential when they are designed as nearly zero-energy container buildings (NZECBs). Thus, they are relevant to energy transition in achieving an almost climate-neutral building stock. This paper describes and applies design strategies for suitable building concepts and energy systems to be used in NZECBs for different climates. Therefore, different applications in representative climatic zones were selected. Initially, the global climate zones were characterized and analyzed with regard to their potential for self-sufficiency and renewable energies in buildings. The design strategies were further developed and demonstrated for three cases: a single-family house in Sweden, a multi-family house in Germany, and a small school building in rural Ethiopia. For each case, design guidelines were derived and building concepts were developed. On the basis of these input data, various energy concepts were developed in which solar and wind energy, as well as biomass, were integrated as renewable energy sources. All the concepts were simulated and analyzed with the Polysun® software. The various approaches were compared and evaluated, particularly with regard to energy self-sufficiency. Self-sufficiency rates up to 80% were achieved. Finally, the influence of different climate zones on the energy efficiency of the single-family house was studied as well as the influence of the size of battery storage and insulation.


Buildings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 215
Author(s):  
Bojana Petrović ◽  
Xingxing Zhang ◽  
Ola Eriksson ◽  
Marita Wallhagen

The objective of this paper was to explore long-term costs for a single-family house in Sweden during its entire lifetime. In order to estimate the total costs, considering construction, replacement, operation, and end-of-life costs over the long term, the life cycle cost (LCC) method was applied. Different cost solutions were analysed including various economic parameters in a sensitivity analysis. Economic parameters used in the analysis include various nominal discount rates (7%, 5%, and 3%), an inflation rate of 2%, and energy escalation rates (2–6%). The study includes two lifespans (100 and 50 years). The discounting scheme was used in the calculations. Additionally, carbon-dioxide equivalent (CO2e) emissions were considered and systematically analysed with costs. Findings show that when the discount rate is decreased from 7% to 3%, the total costs are increased significantly, by 44% for a 100-year lifespan, while for a 50 years lifespan the total costs show a minor increase by 18%. The construction costs represent a major part of total LCC, with labor costs making up half of them. Considering costs and emissions together, a full correlation was not found, while a partial relationship was investigated. Results can be useful for decision-makers in the building sector.


1991 ◽  
Vol 18 (6) ◽  
pp. 893-903 ◽  
Author(s):  
Inderjit Singh ◽  
Donald S. Mavinic

Samples were taken from 72 high-rise apartment suites (6 suites in 12 individual high-rise towers) and 60 single-family houses located within the Greater Vancouver Regional District. The influence of the following factors on trace metal concentrations in 1-L first-flush drinking water samples and “running” hot water samples was investigated: building height, location, plumbing age, type of plumbing, and type of building. Results of this survey show that with the exception of building height, all factors had a correlation with one or more of the trace metals investigated. The trace metals examined were lead, copper, iron, and zinc. Lead was influenced primarily by building type, copper by plumbing age and type of plumbing, and iron by location. Elevated lead levels were associated with high-rise samples. New copper plumbing systems resulted in high copper levels. Highest iron levels in the drinking water were measured in the East Vancouver location. Zinc did not show a distinct correlation with any of the factors investigated. Brass faucets were the primary source of zinc in tap water. They also contributed substantially to the lead detected in the 1-L first-flush sample. Metal concentrations measured in the high-rise and house samples were compared with the U.S. Environmental Protection Agency's (USEPA) maximum contaminant levels (MCLs) and the proposed “no-action” level for lead. In high-rise samples, the 0.01 mg/L “no-action” level proposed for lead was exceeded in 43% of the samples, and 62% of the samples exceeded the current 1.0 mg/L MCL standard for copper. In single-family house samples, these values were 47% and 73%, respectively. The average lead concentrations were 0.020 mg/L for all high-rise samples and 0.013 mg/L for house samples. Regulatory levels stated above would still be exceeded in 6% of the cases for lead and 9% of the cases for copper, even after prolonged flushing of the tap in a high-rise building. In all cases associated with single-family houses, flushing the cold water tap for 5 minutes was successful in achieving compliance levels. Key words: aggressive water, compliance, corrosive, drinking water, first-flush, GVRD, high-rise, single-family house, trace metals, USEPA.


2021 ◽  
pp. 84-87
Author(s):  
Alejandro Beals ◽  
Loreto Lyon

Between 1963 and 1966 Emilio Duhart (1917-2006) worked on the design of this single-family house in what used to be the outskirts of Santiago. During this period, a series of younger collaborators worked on the project, transforming it continuously. Now, confronted with the task of refurbishing the house, we trace back and try to understand the project development by researching archival material. However, it is the process of physically dismantling damaged fabric – almost everything, besides the concrete structure – that really reveals the main principles behind the whole design process. A silent dialogue with architects already gone, which provides the guidelines to write just another chapter in the life of this structure.


Sign in / Sign up

Export Citation Format

Share Document