Economic and Technical Aspects of a Hybrid Single-Family House Heating Based on Photovoltaic and Heat Pump Installation

Author(s):  
Agnieszka Joanna Drzymala ◽  
Ewa Korzeniewska
2018 ◽  
Vol 3 (2) ◽  
pp. 58-61
Author(s):  
Agnieszka Lisowska-Lis ◽  
Robert Leszczyński

The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.


Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5476
Author(s):  
Sławomir Zator ◽  
Waldemar Skomudek

This article presents a case study of a single-family house, whose current energy source is electricity only. Nine years ago, the heat source for the heating system and domestic hot water was an oil boiler, which was changed to an air–water heat pump. Four years ago, when Poland formed the basis of the prosumer market, the first photovoltaic system was established. It was expanded in the following years. In this work are presented the impact of using a heat accumulator on the coefficient of performance of the heat pump, the self-consumption of energy from the photovoltaic system, and the cost of purchasing energy. Comparative calculations were made, with the demand-side management (DSM) active on work days, and on free days (weekends and public holidays) it was not. Attention was paid to the self-consumption factor depending on the algorithms used in an energy meter. The prosumer market in Poland was also described. The calculations described the house as having an annual energy self-consumption from photovoltaic about 6% higher than average values obtained in buildings with heat pumps. Simultaneously, due to energy storage in heat and the load shifting in the multi-zone tariff, the cost of purchasing energy was 47% lower than in a single-zone tariff (without heat storage and load shifting).


2019 ◽  
Vol 111 ◽  
pp. 01003
Author(s):  
Andreas Heinz ◽  
Christian Gaber

The aim of this work is the analysis of hybrid heating systems consisting of an air source heat pump, a storage tank and a photovoltaic (PV) system for the use in renovated residential buildings. The potential for decreasing the electrical energy consumption of the heat pump from the grid by targeted operation of the speed controlled compressor with electricity from PV is determined by means of dynamic system simulations in TRNSYS for a renovated single family house under the assumption that the existing radiator heating system is not replaced, and that therefore relatively high supply temperatures are necessary. Different variants were considered with regard to the size of the PV system, the storage volume and the influence of the heat emission system.


2018 ◽  
Vol 44 ◽  
pp. 00162 ◽  
Author(s):  
Kamil Skoneczny

In the article it was discussed how the energy efficiency of the air-to-water heat pump can change depending on the different ways of the building usage. The author shows that the following factors influence this efficiency: the DHW demand and the demand of the energy for the heating of the building. The article shows that it is very important to take into account the cooperation of both systems, the DHW and the heating. Two models of the SCOP calculations were discussed: in monthly and hourly steps of the calculation. For each model the following assumptions were considered: the different profiles of the domestic hot water demand and the different profiles of the demand for the heating of building.


Proceedings ◽  
2020 ◽  
Vol 51 (1) ◽  
pp. 11
Author(s):  
Agata Witkowska ◽  
Dorota Anna Krawczyk

In recent years, modern and energy-saving solutions, such as heat pumps or solar collectors, have enjoyed great popularity in the heating and cooling sector, which is conditioned by political and environmental factors. The aim of this paper was to analyze the advisability of the employment of renewable energy sources, such as a heat pump, for heating and cooling in single-family buildings in Poland and Spain. Based on the calculations made for a traditional house, located in two cities with different climatic conditions—Wroclaw and Cordoba, the heat losses and gains were determined. On that basis, the heating and cooling demand for these locations were calculated and next—taking into account the obtained results—reversible air–water heat pumps were selected. In addition, the investment expenditures for purchase and assembly of the heat pumps were estimated, as well as the operating costs of the installation. After a deep analysis, it was found that the total cost of using an air-source heat pump, is almost 44% lower for Cordoba, than for Wroclaw.