scholarly journals HUMAN AS A PHYSIOLOGICAL SOURCE OF DETERIORATION OF THE AIR QUALITY AND COMFORT CONDITIONS INDOORS

2019 ◽  
Vol 7 ◽  
pp. 875-879 ◽  
Author(s):  
Radostina A. Angelova ◽  
Peter Stankov ◽  
Detelin Markov ◽  
Rositsa Velichkova ◽  
Iskra Simova

It is imperative a model be developed that can assess the difference between the amount of CO2, generated within the human body and the amount of CO2 that is ejected by the body as a function of indoor air parameters. This model would allow the assessment of the amount of the CO2 which is not ejected by the body through exhalation and which have to be neutralized and ejected by the body through other mechanisms or have to be accumulated in the body depots. Currently, there is no experimental data that allows for predicting the amount of CO2, ejected through the blood gas exchange in the lungs as a function of CO2 concentration in the inhaled air. Our study, conducted within the AIRMEN project, aims to research the phenomenology of the human body as a physiological source of the deterioration of both the indoor environment and conditions of comfort and in particular on the indoor air quality. It is based on an experimental investigation of the external result from the human body metabolism and gas exchange in the lungs. The results of this study make it possible to logically define the limits of the permissible CO2 concentration in the indoor air for the different air quality categories indoors.

Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Author(s):  
Seyed Ali Keshavarz ◽  
Mazyar Salmanzadeh ◽  
Goodarz Ahmadi

Recently, attention has been given to indoor air quality due to its serious health concerns. Clearly the dispersion of pollutant is directly affected by the airflow patterns. The airflow in indoor environment is the results of a combination of several factors. In the present study, the effects of thermal plume and respiration on the indoor air quality in a ventilated cubicle were investigated using an unsteady computational modeling approach. The person-to-person contaminant transports in a ventilated room with mixing and displacement ventilation systems were studied. The effects of rotational motion of the heated manikins were also analyzed. Simulation results showed that in the cases which rotational motion was included, the human thermal plume and associated particle transport were significantly distorted. The distortion was more noticeable for the displacement ventilation system. Also it was found that the displacement ventilation system lowered the risk of person-to-person transmission in an office space in comparison with the mixing ventilation system. On the other hand the mixing system was shown to be more effective compared to the displacement ventilation in removing the particles and pollutant that entered the room through the inlet air diffuser.


Author(s):  
Marek Telejko ◽  
Ewa Zender-Swiercz

Most primary school buildings in Poland rely on natural ventilation. This fact is attributed to the age of these buildings constructed more than dozen or even several tens of years ago. Few of them were fitted with a mechanical ventilation system allowing for the adjustment of microclimate parameters. The national requirements for gravity ventilation provide general guidelines, specifying strict description only for the airtightness of windows and doors and the minimum airflow to be supplied to the rooms. The minimum airflow supplied is independent of the number of occupants and purpose of the room. Low indoor air quality (IAQ) can impact occupants’ health and lead to poor productivity or low academic performance. Therefore the provision of good IAQ in classrooms and laboratories is very important. This paper presents the results of the investigation devoted to the quality of indoor air in classrooms of selected Polish primary school. Six primary school in a town with a population of 200 000 inhabitants were involved in the investigations. The participating school buildings were built between 1976 and 1994 and had gravity ventilation systems. The variability of basic IAQ parameters, i.e., temperature, relative humidity and carbon dioxide level, was analysed and the assessment of the classrooms in terms of microbiological purity was performed. The outcomes confirmed the low quality of the indoor air in these buildings. The maximum value of CO2 concentration amounted to more than 4000 ppm. Certain modifications aimed at improving IAQ were proposed during the investigations. Two solutions were implemented. The results of this study indicate that the proposed solution offers the potential to improve IAQ within classrooms.


2019 ◽  
Vol 111 ◽  
pp. 02017 ◽  
Author(s):  
Mervi Ahola ◽  
Jorma Säteri ◽  
Laura Sariola

The Finnish Society of Indoor Air Quality and Climate (FiSIAQ) introduced a Classification of Indoor Climate, Construction Cleanliness, and Finishing Materials in 1995. The Classification of Indoor Climate has been revised to meet the new Decree on indoor air quality and ventilation, European standards and experience from users of the classification. The most significant change is that target values for concentration and the in/out ratio of fine particles have been added. Other adjustments have been made to ensure good indoor environment and energy efficiency, but with reasonable investments. The criteria for emissions from building material and furniture were also updated. The Building Information Foundation RTS sr has run the M1-labelling of building products since 1996. The voluntary approach has been proven to improve the IAQ in new buildings and to reduce emissions from building materials. The Classification of Indoor Environment 2018 is integrated part of the new RTS Environmental Classification system.


2014 ◽  
Vol 40 (3) ◽  
pp. 259-268 ◽  
Author(s):  
Ana Maria da Conceição Ferreira ◽  
Massano Cardoso

Objective: To determine whether indoor air quality in schools is associated with the prevalence of allergic and respiratory diseases in children. Methods: We evaluated 1,019 students at 51 elementary schools in the city of Coimbra, Portugal. We applied a questionnaire that included questions regarding the demographic, social, and behavioral characteristics of students, as well as the presence of smoking in the family. We also evaluated the indoor air quality in the schools. Results: In the indoor air of the schools evaluated, we identified mean concentrations of carbon dioxide (CO2) above the maximum reference value, especially during the fall and winter. The CO2 concentration was sometimes as high as 1,942 ppm, implying a considerable health risk for the children. The most prevalent symptoms and respiratory diseases identified in the children were sneezing, rales, wheezing, rhinitis, and asthma. Other signs and symptoms, such as poor concentration, cough, headache, and irritation of mucous membranes, were identified. Lack of concentration was associated with CO2 concentrations above the maximum recommended level in indoor air (p = 0.002). There were no other significant associations. Conclusions: Most of the schools evaluated presented with reasonable air quality and thermal comfort. However, the concentrations of various pollutants, especially CO2, suggest the need for corrective interventions, such as reducing air pollutant sources and improving ventilation. There was a statistically significant association between lack of concentration in the children and exposure to high levels of CO2. The overall low level of pollution in the city of Coimbra might explain the lack of other significant associations.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


Author(s):  
Cesira Pasquarella ◽  
Carla Balocco ◽  
Maria Eugenia Colucci ◽  
Elisa Saccani ◽  
Samuel Paroni ◽  
...  

Surgical staff behavior in operating theatres is one of the factors associated with indoor air quality and surgical site infection risk. The aim of this study was to apply an approach including microbiological, particle, and microclimate parameters during two simulated surgical hip arthroplasties to evaluate the influence of staff behavior on indoor air quality. During the first hip arthroplasty, the surgical team behaved correctly, but in the second operation, behavioral recommendations were not respected. Microbiological contamination was evaluated by active and passive methods. The air velocity, humidity, temperature, and CO2 concentration were also monitored. The highest levels of microbial and particle contamination, as well as the highest variation in the microclimate parameter, were recorded during the surgical operation where the surgical team behaved “incorrectly”. Turbulent air flow ventilation systems appeared more efficient than in the past and very low air microbial contamination was reached when behavior was correct. Therefore, adherence to behavioral recommendations in operating theatres is essential to not undermine the effectiveness of the heating, ventilation, and air conditioning systems and employed resources.


Atmosphere ◽  
2020 ◽  
Vol 11 (3) ◽  
pp. 271 ◽  
Author(s):  
Kanittha Pamonpol ◽  
Thanita Areerob ◽  
Kritana Prueksakorn

Optimum thermal comfort and good indoor air quality (IAQ) is important for occupants. In tropical region offices, an air conditioner is indispensable due to extreme high temperatures. However, the poor ventilation causes health issues. Therefore, the purpose of this study was to propose an improving IAQ method with low energy consumption. Temperature, relative humidity, and CO2 and CO concentration were monitored in a poorly ventilated office for one year to observe seasonal variation. The results showed that the maximum CO2 concentration was above the recommended level for comfort. Simple ventilated practices and placing a number of Sansevieria trifasciata (S. trifasciata) plants were applied to improve the IAQ with the focus on decreasing CO2 concentration as well as achieving energy saving. Reductions of 19.9%, 22.5%, and 58.2% of the CO2 concentration were achieved by ventilation through the door during lunchtime, morning, and full working period, respectively. Placing S. trifasciata in the office could reduce the CO2 concentration by 10.47%–19.29%. A computer simulation was created to observe the efficiency of simple practices to find the optimum conditions. An electricity cost saving of 24.3% was projected for the most feasible option with a consequent reduction in global warming potential, which also resulted in improved IAQ.