scholarly journals FORENSIC MEDICAL CRITERIA OF DIFFERENTIAL DIAGNOSIS OF ALCOHOL AND CARBON MONOXIDE POISONING BY USING AZIMUTHAL-INVARIANT POLARIZATION MUELLER-MATRIX MICROSCOPY

2021 ◽  
Vol 2 ◽  
pp. 33-40
Author(s):  
Olexandr Harazdiuk ◽  
Ihor Ivaskevich ◽  
Oleh Vanchuliak ◽  
Yuliia Sarkisova

Introduction: Fatal intoxications with alcohol and carbon monoxide are the most common causes of poisoning that occur in forensic medical practice. Therefore, the differential diagnosis of these intoxications is extremely important. To solve this problem, we propose the use of the method of azimuthal-invariant polarization Mueller-matrix microscopy of histological sections of biological tissues (BT). Objectives: The purpose of the study was to establish statistically significant criteria for differentiation of the cause of death in case of alcohol poisoning (AP) and carbon monoxide poisoning (CMP) by using azimuthal-invariant polarization Mueller-matrix microscopy of polycrystalline fractions of histological sections of organs and blood films of the human body. Results: A number of characteristic features have been identified that have not been previously described and allow to objectively differentiate the cause of death in the case of AP and CMP, namely Ek – 0.95±0.045 and 1.81±0.092 in the study of histological sections of the myocardium;  Ek – 0,19±0,011 and 1,11±0,094 – polycrystalline blood films. Analysis of the obtained data revealed a good level of accuracy in the study of histological sections of the myocardium (As 85%) and polycrystalline blood films (As 88%). Conclusion: Thus, developed and tested method of azimuthal-invariant polarization Mueller-matrix microscopy allows to differentiate the cause of death in cases of AP and CMP.

2020 ◽  
Vol 1 ◽  
pp. 41-47
Author(s):  
Ihor Ivaskevich ◽  
Oleh Vanchuliak ◽  
Viktor Bachynskіy ◽  
Sviatoslava Yurniuk

Introduction: This paper aims to investigate and substantiate the information capabilities of the objective method of azimuthal-invariant polarization Müller-matrix microscopy of histological sections of biological tissues (BT) in the diagnosis of time since death (TSD) in alcohol and monoxide poisoning. Objectives: The purpose of the study was to evaluate the diagnostic capabilities of the azimuthal-invariant Muller-matrix polarimetry technique of the polycrystalline constituent of BT and human body fluids in determining the TSD in cases of alcohol and carbon monoxide poisoning. Results: A comprehensive experimental study of the diagnostic efficiency of the azimuthal-invariant Muller-matrix polarimetric microscopy of the polycrystalline component of histological sections of the brain, myocardium, adrenal glands, liver, and polycrystalline blood films from dead persons for the diagnosis of TSD in cases of alcohol and carbon monoxide poisoning.A sensitivity range of 24 hours was determined using the method of the azimuthal-invariant Muller-matrix polarimetric microscopy of the polycrystalline component of histological sections of the myocardium for the diagnosis of TSD in cases of alcohol and carbon monoxide poisoning. Conclusion: The results showed the effectiveness of the studied methodology and the prospect of further research in this direction.


2015 ◽  
Vol 45 (3) ◽  
pp. 265-269 ◽  
Author(s):  
V A Ushenko ◽  
M I Sidor ◽  
Yu F Marchuk ◽  
N V Pashkovskaya ◽  
D R Andreichuk

2019 ◽  
Vol 35 (4) ◽  
pp. 877-891 ◽  
Author(s):  
L. Trifonyuk ◽  
A. Sdobnov ◽  
W. Baranowski ◽  
V. Ushenko ◽  
O. Olar ◽  
...  

AbstractSince recently, a number of innovative polarization-based optical imaging modalities have been introduced and extensively used in various biomedical applications, with an ultimate aim to attain the practical tool for the optical biopsy and functional characterization of biological tissues. The techniques utilize polarization properties of light and Mueller matrix mapping of microscopic images of histological sections of biological tissues or polycrystalline films of biological fluids. The main drawback of currently developed laser polarimetry approaches and Mueller matrix mapping techniques is poor reproducibility of experimental data. This is due to azimuthal dependence of polarization and ellipticity values of most matrix elements to sample orientation in respect to incidence light polarization. Current study aims to generalize the methods of laser polarimetry for diagnosis of partially depolarizing optically anisotropic biological tissues. A method of differential Mueller matrix mapping for reconstruction of linear and circular birefringence and dichroism parameter distributions of partially depolarizing layers of biological tissues of different morphological structure is introduced and practically implemented. The coordinate distributions of the value of the first-order differential matrix elements of histological sections of brain tissue with spatially structured, optically anisotropic fibrillar network, as well as of parenchymatous tissue of the rectum wall with an “islet” polycrystalline structure are determined. Within the statistical analysis of polarization reproduced distributions of the averaged parameters of phase and amplitude anisotropy, the significant sensitivity of the statistical moments of the third and fourth orders to changes in the polycrystalline structure of partially depolarizing layers of biological tissue is observed. The differentiation of female reproductive sphere connective tissue is realized with excellent accuracy. The differential Mueller matrix mapping method for reconstruction of distributions of linear and circular birefringence and dichroism parameters of partially depolarizing layers of biological tissues of different morphological structures is proposed and substantiated. Differential diagnostics of changes in the phase (good balanced accuracy) and amplitude (excellent balanced accuracy) of the anisotropy of the partially depolarizing layers of the vagina wall tissue with prolapse of the genitals is realized. The maximum diagnostic efficiency of the first-order differential matrix method was demonstrated in comparison with the traditional methods of polarization and Mueller matrix mapping of histological sections of light-scattering biological tissues.


2010 ◽  
Vol 124 (10) ◽  
pp. 1103-1105 ◽  
Author(s):  
R Lakhani ◽  
N Bleach

AbstractObjective:We report an unusual case of dizziness caused by carbon monoxide poisoning.Case report:A 55-year-old man was referred to an ENT surgeon with dizziness. The patient described vague, non-specific symptoms not consistent with a diagnosis of benign paroxysmal positional vertigo, labyrinthitis or Ménière's disease. It emerged later that the patient had been suffering from carbon monoxide poisoning from a leaky gas hot water boiler in his house. After having the boiler fixed, the patient's symptoms completely resolved.Conclusion:When the more common causes of dizziness cannot be found, less common but important differential diagnoses, such as carbon monoxide poisoning, should be considered.


2021 ◽  
pp. 25-35
Author(s):  
Marta Garazdiuk

For a forensic expert-practitioner, it is especially important to objectively diagnose and time since the formation of hemorrhage (TSFH) in the substance of the human brain (SHB) of traumatic and non-traumatic origin, as there are cases when the external examination of the corpse at the scene are absent, and at internal research find hemorrhages in a brain. In forensic practice, to verify the cause of death, physical-optical methods are successfully used, which are based on laser irradiation of biological tissues with subsequent mathematical and statistical processing of the obtained data. Previous studies on the possibility of differentiating the cause of death by traditional polarization methods have yielded positive results, which suggests the possibility of their suitability for verification of the genesis of hemorrhage into the brain. For a forensic expert-practitioner, the main thing is objectivity, accuracy and speed of obtaining the result, which could fully satisfy the methods of laser polarimetry in the case of determining the TSFH of traumatic and non-traumatic origin in SHB. Therefore, it is necessary to continue the development and research of these methods for this purpose. Aim of the work. To substantiate the possibility of using the method of differential Mueller-matrix mapping of phase anisotropy to determine the temporal dynamics of maps of linear birefringence of histological sections of human brain in determining the age of hemorrhage in human brain substance and to develop forensic criteria for determining the age. death due to cerebral infarction of ischemic and hemorrhagic origin. Materials and methods. To achieve this goal, we studied native histological preparations SHB from 130 corpses with a known time of death. The cause of death was TBI (group II (n=35)), cerebral infarction of ischemic origin (group III (n=32)), hemorrhagic stroke (group IV (n=33)), acute coronary insufficiency (group I – comparison group (n=30)). The values of the distribution of the coordinates of the polarization parameters at the points of the microscopic images at the location of the standard Stokes polarimeter were measured. Experimental measurements of Stokes-parametric images of biological layers were performed according to the method presented in the sources. Subsequently, the obtained data were subjected to statistical processing and evaluation of the obtained results. Statistical moments (SM) of the 1st-4th orders (mean (SM1), variance (SM2), asymmetry (SM3) and excess (SM4)) of each map were determined. Results and discussion. Comparative analysis of polarization Mueller-matrix mapping images of SHB sections from all groups revealed the destruction of the polycrystalline structure formed by optically active protein complexes of the brain substance, which indicates a decrease in absolute values and range of their scatter with increasing hemorrhage time. This is indicated by the coordinate inhomogeneity of the Mueller-matrix invariant maps of histological sections of SHB of all groups. For histograms that characterize the distributions of the Mueller-matrix invariant samples from all (comparison groups 1 and experimental 2-4) groups, are characterized by individual and significant variations in the values of statistical moments. Due to this, with increasing hemorrhage time, the value of the mean (SM1) and variance (SM2) decreases. Asymmetry (SM3) and excess (SM4), on the contrary, increase. The analysis of the results of statistical processing of the topographic structure of LD tomograms of fibrillar networks of histological sections of SHB dead from all groups shows a greater temporal dynamics of necrotic destruction of nervous tissue. Accordingly, there is a faster time decrease in the absolute values and the range of scatter of the LD value with increasing TSFH. That is, the diagnostic sensitivity of the statistical moments of the 3rd and 4th orders for azimuthal-invariant Mueller-matrix differentiation of nerve tissue samples of the brain of the deceased of control group 1 and all experimental groups 2-4 (p<0,05) was revealed. Conclusions. A series of studies of the effectiveness of a new in forensic practice method of differential Mueller-matrix mapping of partially depolarizing histological sections of SHB and tomographic reproduction of optical anisotropy parameters of their polycrystalline structure revealed a high level of accuracy of differentiation and formation of genesis, even under conditions of small geometric thickness of experimental samples. The range of linear change of values of statistical moments of the 1st - 4th orders which characterize distributions of size of LD of fibrillar networks of histologic sections of SHB of the dead from all groups, makes 24 h. In the range of 6-24 hours, the accuracy of determining the TSFH using statistical processing of the topographic structure of LD tomograms of fibrillar networks of histological sections of TSFH is (30±5) minutes.


2021 ◽  
pp. 55-63
Author(s):  
Igor Ivaskevych ◽  
Oleh Vanchulyak ◽  
Oleksandr Olar

This work is devoted to the study of the possibilities of applying the method of differential polarimetric microscopy with algorithmic reproduction of fluctuations of linear and circular birefringence of polycrystalline component of human blood films in forensic practice for differential diagnosis of alcohol and carbon monoxide poisoning. Aim of the work. Development of a set of forensic objective criteria for the possibility of differential diagnosis of ethanol and CO poisoning by diffuse tomography of polarization images of polycrystalline films of human blood. Materials and methods. The object of the study were polycrystalline blood films obtained from 98 corpses of both sexes aged 18 to 70 years. The cause of death was acute ethanol poisoning (n=36), acute CO poisoning (n=32) and biological tissue samples from those who died of coronary heart disease (n=30) were used for control. The studies were performed by diffuse tomography of linear and circular birefringence of fluctuations of the polycrystalline structure of human blood films. Results. The results of statistical analysis of data of algorithmic polarization reproduction of coordinate distributions of linear birefringence of fluctuation of albumin-globulin polycrystalline networks and circular birefringence of optically active chiral molecules, revealed a high level (statistical reliability p1; p2; p1;2<0,05) of diagnostic efficiency of forensic digital differentiation of blood films samples from people died of coronary heart disease, ethanol and carbon monoxide poisoning based on the calculation of a set of statistical moments of the 1-4-th orders. Conclusions. The possibility of statistically significant (p1; p2<0,05) differentiation of cases of ethanol and CO poisoning by diffuse tomography of linear and circular birefringence of fluctuations of the polycrystalline component of the blood films has been established. The operational characteristics of the diagnostic power of the method corresponding to the excellent (92 % and 97 %) level are determined.


2014 ◽  
Vol 07 (01) ◽  
pp. 1350028 ◽  
Author(s):  
E DU ◽  
HONGHUI HE ◽  
NAN ZENG ◽  
CELONG LIU ◽  
YIHONG GUO ◽  
...  

We developed a model to describe polarized photon scattering in biological tissues. In this model, tissues are simplified to a mixture of scatterers and surrounding medium. There are two types of scatterers in the model: solid spheres and infinitely long solid cylinders. Variables related to the scatterers include: the densities and sizes of the spheres and cylinders, the orientation and angular distribution of cylinders. Variables related to the surrounding medium include: the refractive index, absorption coefficient and birefringence. In this paper, as a development we introduce an optical activity effect to the model. By comparing experiments and Monte Carlo simulations, we analyze the backscattering Mueller matrix patterns of several tissue-like media, and summarize the different effects coming from anisotropic scattering and optical properties. In addition, we propose a possible method to extract the optical activity values for tissues. Both the experimental and simulated results show that, by analyzing the Mueller matrix patterns, the microstructure and optical properties of the medium can be obtained. The characteristic features of Mueller matrix patterns are potentially powerful tools for studying the contrast mechanisms of polarization imaging for medical diagnosis.


2015 ◽  
Vol 253 ◽  
pp. 112-118 ◽  
Author(s):  
Feng Li ◽  
Heng Choon (Oliver) Chan ◽  
Sihai Liu ◽  
Haipeng Jia ◽  
Hongjun Li ◽  
...  

2021 ◽  
Vol 25 (1(97)) ◽  
pp. 24-30
Author(s):  
M. Garazdiuk ◽  
O. Dubolazov ◽  
V. Tiulienieva

Abstract. The aim of the work is to develop forensic criteria for differential diagnosis of traumatic hemorrhages (HTG), ischemic stroke (IS), and hemorrhages of nontraumatic genesis (HNG) formation by 3D Mueller-matrix microscopy of layers of azimuthal-invariant Mueller-matrix images of circular birefringence of histological sections of the brain. Material and methods. Native sections of brain taken from 110 corpses were used for the study in the case of: death from coronary heart disease - 20 (18.1%) native sections (group 1 - control); HTG - 30 (27.3%) sections (group 2), IIB - 30 (27.3%) sections (group 3), HNG - 30 (27.3%) sections (group 4). Measurement of the values of the distribution of coordinate parameters of polarization at the points of microscopic images was performed at the location of the standard Stokes polarimeter. Results. It is found that for each of the phase cross-sections of the field, the volume of distributions of complex amplitudes of sensitivity, specificity and balanced accuracy of statistical analysis of coordinate distributions of Mueller-matrix invariants of circular dichroism have maximum values for small phase shifts corresponding to their level. The maximum level of balanced accuracy of intergroup differentiation was revealed by calculating statistical moments of the 3rd and 4th order, which characterize the asymmetry and excess distributions of the Mueller-matrix invariants values of circular dichroism of histological sections of brain substance. Conclusions. Excellent balanced accuracy (95% - 96%) of differential diagnosis was achieved between the control group and all study groups, good accuracy (92% - 93%) between ischemic stroke and traumatic hemorrhage and satisfactory accuracy (85% - 86%) between traumatic and hemorrhagic strokes genesis.


Sign in / Sign up

Export Citation Format

Share Document