G0310201 Compressive Plastic Deformation in Micro Areas between Parallel Grooves and in V-shaped Cross-Section Groove Fabricated on Polycrystalline Pure Titanium Surface

2014 ◽  
Vol 2014 (0) ◽  
pp. _G0310201--_G0310201-
Author(s):  
Ichiro SHIMIZU ◽  
Katsuhiro ISOKAWA ◽  
Kousuke HARA ◽  
Naoya TADA
2021 ◽  
Vol 28 (1) ◽  
pp. 160-168
Author(s):  
Xi Wang ◽  
Guoli Zhang ◽  
Xiaoping Shi ◽  
Ce Zhang

Abstract A modified vertical braiding machine and closed annular axis mandrels with a special-shaped cross section were used to braid annular axis preforms under four different technical parameters. After measuring the braiding angles and yarn spacing of the braided preform in different areas of the mandrels, it was found that the braiding angle increased by 20.9% and the yarn spacing decreased by 19.8% when the speed of the yarn carrier was doubled. The braiding angle decreased by 31.1% and the yarn spacing increased by 28.6% when the rotation speed of the mandrels was doubled. The results show that the rotation speed of the mandrel has a slightly greater influence on the braiding angle and the yarn spacing. By using the modified braiding machine to braid the annular axis preforms, multi-layer continuous braided preforms can be achieved on compact equipment. And the structure of the annular axis braided preforms can be changed by changing the technical parameters.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Teng Li ◽  
Wenbin Dou

An edge slotted waveguide antenna array based on T-shaped cross-section radiating waveguide is proposed. The T-shaped waveguide is analyzed and designed to operate in dominant mode around the center frequency, which has a lower profile compared with the rectangular one. The radiating slots are etched and rotated alternatively on the broadened top plate without cutting into the adjacent walls. The metal fences are inserted between slots to reduce the mutual coupling and surface wave. Therefore, the sidelobe level in E-plane is well suppressed. A 2 × 8 antenna array working at Ka-band is designed and fabricated. The measured results agree well with simulations which demonstrate this novel waveguide structure.


Author(s):  
Peiqiang Yang ◽  
Xueping Zhang ◽  
Zhenqiang Yao ◽  
Rajiv Shivpuri

Abstract Titanium alloys’ excellent mechanical and physical properties make it the most popular material widely used in aerospace, medical, nuclear and other significant industries. The study of titanium alloys mainly focused on the macroscopic mechanical mechanism. However, very few researches addressed the nanostructure of titanium alloys and its mechanical response in Nano-machining due to the difficulty to perform and characterize nano-machining experiment. Compared with nano-machining, nano-indentation is easier to characterize the microscopic plasticity of titanium alloys. This research presents a nano-indentation molecular dynamics model in titanium to address its microstructure alteration, plastic deformation and other mechanical response at the atomistic scale. Based on the molecular dynamics model, a complete nano-indentation cycle, including the loading and unloading stages, is performed by applying Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS). The plastic deformation mechanism of nano-indentation of titanium with a rigid diamond ball tip was studied under different indentation velocities. At the same time, the influence of different environment temperatures on the nano-plastic deformation of titanium is analyzed under the condition of constant indentation velocity. The simulation results show that the Young’s modulus of pure titanium calculated based on nano-indentation is about 110GPa, which is very close to the experimental results. The results also show that the mechanical behavior of titanium can be divided into three stages: elastic stage, yield stage and plastic stage during the nano-indentation process. In addition, indentation speed has influence on phase transitions and nucleation of dislocations in the range of 0.1–1.0 Å/ps.


2018 ◽  
Vol 416 ◽  
pp. 29-54 ◽  
Author(s):  
Andrew J. Hull ◽  
Daniel Perez ◽  
Donald L. Cox

Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3306
Author(s):  
Yuzhu He ◽  
Yuanyuan Li ◽  
Enjun Zuo ◽  
Songling Chai ◽  
Xiang Ren ◽  
...  

For the benefit of antibacterial Ti on orthopedic and dental implants, a bioactive coating (Pac@PLGA MS/HA coated Ti) was deposited on the surface of pure titanium (Ti), which included two layers: an acid–alkali heat pretreated biomimetic mineralization layer and an electrosprayed Poly (D,L-lactide-co- glycolic acid) (PLGA) microsphere layer as a sustained-release system. Hydroxyapatite (HA) in mineralization layer was primarily prepared on the Ti followed by the antibacterial coating of Pac-525 loaded by PLGA microspheres. After observing the antimicrobial peptides distributed uniformly on the titanium surface, the release assay showed that the release of Pac-525 from Pac@PLGA MS/HA coated Ti provided a large initial burst followed by a slow release at a flat rate. Pac@PLGA MS/HA coated Ti exhibited a strong cytotoxicity to both Gram-negative bacteria (Escherichia coli) and Gram-positive bacteria (Staphylococcus aureus). In addition, Pac@PLGA MS/HA coated Ti did not affect the growth and adhesion of the osteoblast-like cell line, MC3T3-E1. These data suggested that a bionic mineralized composite coating with long-term antimicrobial activity was successfully prepared.


2013 ◽  
Vol 49 ◽  
pp. 1042-1047 ◽  
Author(s):  
Qiong Wang ◽  
Ping-Ze Zhang ◽  
Dong-Bo Wei ◽  
Ruo-Nan Wang ◽  
Xiao-Hu Chen ◽  
...  

2007 ◽  
Vol 54 ◽  
pp. 771-775
Author(s):  
Osamu KUNITA ◽  
Masatoshi YUHI ◽  
Junichi YAMAZAKI ◽  
Shinya KOTAKI ◽  
Hajime ISHIDA

Sign in / Sign up

Export Citation Format

Share Document