Robust Control for Flexible Rotor of Magnetic Bearing System

2018 ◽  
Vol 2018.67 (0) ◽  
pp. 111
Author(s):  
Takemitsu TAKAGI ◽  
Chen GAN ◽  
isao TAKAMI
2002 ◽  
Vol 124 (2) ◽  
pp. 186-197 ◽  
Author(s):  
P. S. Keogh ◽  
M. O. T. Cole ◽  
C. R. Burrows

A technique is introduced to achieve transient vibration attenuation in a multi-input, multi-output flexible rotor/magnetic bearing system. The strategy employs feedback control of measured harmonic components of rotor vibration. Whereas previous harmonic controllers have been based only on steady state vibration characteristics, the new controller also incorporates the transient dynamics. The controller may still be designed from measured data and is determined from target transient vibrational responses arising from step changes in particular disturbances. Account is taken of delays arising from evaluation of harmonic components. Furthermore, stability boundaries for the controller are shown to have significant tolerance to measurement error. The controller is validated experimentally in a flexible rotor/magnetic bearing system and mass loss tests are used to demonstrate rapid decrease in vibration levels with near elimination of transient overshoot.


2011 ◽  
Vol 189-193 ◽  
pp. 1592-1596
Author(s):  
Hui Qun Yuan ◽  
Ying Li ◽  
Dong Li ◽  
Wen Bo Wu

Considering gyroscopic effect and flexibility of the shaft, the eight freedoms dynamic model is established. The dynamic characteristic and control quantity in different bearing rigidity and rotation axis are studied and discussed by optimal control theory. Furthermore, the controlling and the responding are discussed. The simulation results show that the bearing rigidity has great effect on the control quantity so that the elasticity of bearing must be considered. The asymmetry rigidity of rotational axis has little influence on stability. The conclusion may bring up theoretical references for precision control for rotor magnetic bearing system.


Author(s):  
E. N. Cuesta ◽  
N. I. Montbrun ◽  
V. Rastelli ◽  
S. E. Diaz

The present work studies the behavior of a magnetic bearing supported rotor when the flow of electric current to the magnetic actuator is suppressed In this condition the rotor is supported by the auxiliary bearing, which has looseness with the rotor, generating a series of impacts between these components. For the study of this state, a model of a flexible rotor is proposed, and the impacts are simulated using kinematical restitution coefficient theory. The results obtained from the theoretical model are compared with experimental data taken on a test rig using tools for non linear systems analysis such bifurcation diagrams. The comparison shows that, besides the simplification of the contact, the model predicts ranges chaotic, quasi-periodic, and periodic motions in the test rig.


Author(s):  
M O T Cole ◽  
P S Keogh ◽  
C R Burrows

During operation, a rotor/magnetic bearing system may be subject to various sources of vibration, either directly applied to the rotor or transmitted through the bearings owing to base motion. This paper considers controller designs that are capable of attenuating vibration arising from either source. It advances the current state of research in the area since other controller designs have considered only the direct forcing case. If base motion is not considered in the design of the controller then this disturbance may cause the bearing clearance limits to be reached. Controller design is formulated as an H∞ optimization problem, with mixed design objectives. A new controller is derived that can simultaneously reduce vibration and minimize the effect of base motion on relative rotor to bearing displacement. Account is taken of the fact that the bearings can apply only limited control force. The design study was complemented by a programme of experimental work. The base of a rig was subjected to impulse inputs and the results show the effectiveness of the new controller design. It is demonstrated that proportional, integral and derivative (PID) controllers, or controllers designed for unbalance vibration attenuation only, may result in rotor contact with retainer bushes, while the new controller may prevent contact. The potential now exists for continuing safe operation of flexible rotor/magnetic bearing systems such as compressors, gas turbines, generators, etc., in transport applications, during seismic events or in environments with expected base input disturbances.


1999 ◽  
Vol 121 (3) ◽  
pp. 504-508 ◽  
Author(s):  
E. H. Maslen ◽  
C. K. Sortore ◽  
G. T. Gillies ◽  
R. D. Williams ◽  
S. J. Fedigan ◽  
...  

A fault tolerant magnetic bearing system was developed and demonstrated on a large flexible-rotor test rig. The bearing system comprises a high speed, fault tolerant digital controller, three high capacity radial magnetic bearings, one thrust bearing, conventional variable reluctance position sensors, and an array of commercial switching amplifiers. Controller fault tolerance is achieved through a very high speed voting mechanism which implements triple modular redundancy with a powered spare CPU, thereby permitting failure of up to three CPU modules without system failure. Amplifier/cabling/coil fault tolerance is achieved by using a separate power amplifier for each bearing coil and permitting amplifier reconfiguration by the controller upon detection of faults. This allows hot replacement of failed amplifiers without any system degradation and without providing any excess amplifier kVA capacity over the nominal system requirement. Implemented on a large (2440 mm in length) flexible rotor, the system shows excellent rejection of faults including the failure of three CPUs as well as failure of two adjacent amplifiers (or cabling) controlling an entire stator quadrant.


Sign in / Sign up

Export Citation Format

Share Document