scholarly journals Thermal Performance of Multilayer Insulation. 2nd Report. Expansion and Application of the Prediction-Based Heat Flux Equation.

1994 ◽  
Vol 60 (569) ◽  
pp. 284-291
Author(s):  
Toshiyuki Amano
Author(s):  
Rama R. Goruganthu ◽  
David Bethke ◽  
Shawn McBride ◽  
Tom Crawford ◽  
Jonathan Frank ◽  
...  

Abstract Spray cooling is implemented on an engineering tool for Time Resolved Emission measurements using a silicon solid immersion lens to achieve high spatial resolution and for probing high heat flux devices. Thermal performance is characterized using a thermal test vehicle consisting of a 4x3 array of cells each with a heater element and a thermal diode to monitor the temperature within the cell. The flip-chip packaged TTV is operated to achieve uniform heat flux across the die. The temperature distribution across the die is measured on the 4x3 grid of the die for various heat loads up to 180 W with corresponding heat flux of 204 W/cm2. Using water as coolant the maximum temperature differential across the die was about 30 °C while keeping the maximum junction temperature below 95 °C and at a heat flux of 200 W/cm2. Details of the thermal performance of spray cooling system as a function of flow rate, coolant


2017 ◽  
Author(s):  
Daniel Madrzykowski ◽  

The goal of this study was to review the available literature to develop a quantitative description of the thermal conditions firefighters and their equipment are exposed to in a structural fire environment. The thermal exposure from the modern fire environment was characterized through the review of fire research studies and fire-ground incidents that provided insight and data to develop a range of quantification. This information was compared with existing standards for firefighting protective equipment to generate a sense of the gap between known information and the need for improved understanding. The comparison of fire conditions with the thermal performance requirements of firefighter protective gear and equipment demonstrates that a fire in a compartment can generate conditions that can fail the equipment that a firefighter wears or uses. The review pointed out the following: 1. The accepted pairing of gas temperature ranges with a corresponding range of heat fluxes does not reflect all compartment fire conditions. There are cases in which the heat flux exceeds the hazard level of the surrounding gas temperature. 2. Thermal conditions can change within seconds. Experimental conditions and incidents were identified in which firefighters would be operating in thermal conditions that were safe for operation based on the temperature and heat flux, but then due to a change in the environment the firefighters would be exposed to conditions that could exceed the protective capabilities of their PPE. 3. Gas velocity is not explicitly considered within the thermal performance requirements. Clothing and equipment tested with a hot air circulating (convection) oven are exposed to gas velocities that measure approximately 1.5 m/s (3 mph). In contrast, the convected hot gas flows within a structure fire could range from 2.3 m/s (5 mph) to 7.0 m/s (15 mph). In cases where the firefighter or equipment would be located in the exhaust portion of a flow path, while operating above the level of the fire, the hot gas velocity could be even higher. This increased hot gas velocity would serve to increase the convective heat transfer rate to the equipment and the firefighter, thereby reducing the safe operating time within the structure. 4. Based on the limited data available, it appears currently available protective clothing enables firefighters to routinely operate in conditions above and beyond the "routine" conditions measured in the fire-ground exposure studies conducted during the 1970s. The fire service and fire standards communities could benefit from an improved understanding of: • real world fire-ground conditions, including temperatures, heat flux, pressure, and chemical exposures; • the impact of convection on the thermal resistance capabilities of firefighting PPE and equipment; and • the benefits of balancing the thermal exposures (thermal performance requirements) across different components of firefighter protective clothing and safety equipment. Because it is unlikely due to trade offs in weight, breathe-ability, usability, cost, etc., that fireproof PPE and equipment will ever be a reality, fire officers and fire chiefs need to consider the capabilities of the protection that their firefighters have when determining fire attack strategies and tactics to ensure that the PPE and equipment is kept within its design operating environment, and that the safety buffer it provides is maintained.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2145 ◽  
Author(s):  
Ning Qian ◽  
Yucan Fu ◽  
Marco Marengo ◽  
Jiuhua Xu ◽  
Jiajia Chen ◽  
...  

In order to enhance heat transfer in the abrasive-milling processes to reduce thermal damage, the concept of employing oscillating heat pipes (OHPs) in an abrasive-milling tool is proposed. A single-loop OHP (SLOHP) is positioned on the plane parallel to the rotational axis of the tool. In this case, centrifugal accelerations do not segregate the fluid between the evaporator and condenser. The experimental investigation is conducted to study the effects of centrifugal acceleration (0–738 m/s2), heat flux (9100–31,850 W/m2) and working fluids (methanol, acetone and water) on the thermal performance. Results show that the centrifugal acceleration has a positive influence on the thermal performance of the axial-rotating SLOHP when filled with acetone or methanol. As for water, with the increase of centrifugal acceleration, the heat transfer performance first increases and then decreases. The thermal performance enhances for higher heat flux rises for all the fluids. The flow inside the axial-rotating SLOHP is analyzed by a slow-motion visualization supported by the theoretical analysis. Based on the theoretical analysis, the rotation will increase the resistance for the vapor to penetrate through the liquid slugs to form an annular flow, which is verified by the visualization.


Sign in / Sign up

Export Citation Format

Share Document