scholarly journals Electromagnetic binding and radiation force reversal on a pair of electrically conducting cylinders of arbitrary geometrical cross-section with smooth and corrugated surfaces

OSA Continuum ◽  
2018 ◽  
Vol 1 (2) ◽  
pp. 521 ◽  
Author(s):  
F. G. Mitri
1993 ◽  
Vol 46 (1) ◽  
pp. 13 ◽  
Author(s):  
LF Phillips

Quasi-classical trajectory calculations have been used to calculate effective collision cross-sections for polar and non-polar molecules with charged and neutral conducting spheres of radius 0.001-0.1 μm over the temperature range 10-400 K. In general the effective cross-section is much larger than the geometrical cross-section, especially for small, highly charged, particles colliding with highly polar molecules at low temperatures. The results may have a bearing on the growth of atmospheric aerosols and of interstellar dust grains.


2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
Mario Lucido ◽  
Chiara Santomassimo ◽  
Fulvio Schettino ◽  
Marco Donald Migliore ◽  
Daniele Pinchera ◽  
...  

The analysis of the TM electromagnetic scattering from perfectly electrically conducting polygonal cross-section cylinders is successfully carried out by means of an electric field integral equation formulation in the spectral domain and the method of analytical preconditioning which leads to a matrix equation at which Fredholm’s theory can be applied. Hence, the convergence of the discretization scheme is guaranteed. Unfortunately, the matrix coefficients are improper integrals involving oscillating and, in the worst cases, slowly decaying functions. Moreover, the classical analytical asymptotic acceleration technique leads to faster decaying integrands without overcoming the most important problem of their oscillating nature. Thus, the computation time rapidly increases as higher is the accuracy required for the solution. The aim of this paper is to show a new analytical technique for the efficient evaluation of such kind of integrals even when high accuracy is required for the solution.


2021 ◽  
Vol 10 (20) ◽  
pp. 4713
Author(s):  
Vicente Faus-Llácer ◽  
Nirmine Hamoud-Kharrat ◽  
María Teresa Marhuenda Ramos ◽  
Ignacio Faus-Matoses ◽  
Álvaro Zubizarreta-Macho ◽  
...  

The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10); B: 20.04 rectangular cross-section NiTi alloy endodontic rotary files (T Pro E1) (n = 10); C: 25.04 convex triangular cross-section NiTi alloy endodontic rotary files (T Pro E2) (n = 10); and D: 25.06 triangular cross-section NiTi alloy endodontic rotary files (T Pro E4) (n = 10). A cyclic fatigue device was used to conduct the static cyclic fatigue tests with stainless steel artificial root canal systems with 200 µm and 250 µm apical diameter, 60° curvature angle, 3 mm radius of curvature, 20 mm length, and 4% and 8% taper. The results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All the pairwise comparisons presented statistically significant differences between the time to failure and number of cycles to failure for the cross-section design study groups (p < 0.001). Conclusions: the double S-shaped cross-section of Mtwo NiTi endodontic files shows higher cyclic fatigue resistance than the rectangular cross-section of T Pro E1 NiTi endodontic files, the convex triangular cross-section of T Pro E2 NiTi endodontic files, and the triangular cross-section of T Pro E4 NiTi endodontic files.


Sign in / Sign up

Export Citation Format

Share Document