scholarly journals Comparison of Droplet Digital PCR and Quantitative PCR Assays for Quantitative Detection of Xanthomonas citri Subsp. citri

PLoS ONE ◽  
2016 ◽  
Vol 11 (7) ◽  
pp. e0159004 ◽  
Author(s):  
Yun Zhao ◽  
Qingyan Xia ◽  
Youping Yin ◽  
Zhongkang Wang
Water ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3507
Author(s):  
Mark A. Ibekwe ◽  
Shelton E. Murinda ◽  
Stanley Park ◽  
Amarachukwu Obayiuwana ◽  
Marcia A. Murry ◽  
...  

E. coli O157:H7 is a foodborne pathogen that constitutes a global threat to human health. However, the quantification of this pathogen in food and environmental samples may be problematic at the low cell numbers commonly encountered in environmental samples. In this study, we used recombinase polymerase amplification (RPA) for the detection of E. coli O157:H7, real-time quantitative PCR (qPCR) for quantification, and droplet digital PCR (ddPCR) for absolute and accurate quantification of E. coli O157:H7 from spiked and environmental samples. Primer and probe sets were used for the detection of stx1 and stx2 using RPA. Genes encoding for stx1, stx2, eae, and rfbE were used to quantify E. coli O157:H7 in the water samples. Furthermore, duplex ddPCR assays were used to quantify the pathogens in these samples. Duplex assay set 1 used stx1 and rfbE genes, while assay set 2 used stx2 and eae genes. Droplet digital PCR was used for the absolute quantification of E. coli O15:H7 in comparison with qPCR for the spiked and environmental samples. The RPA results were compared to those from qPCR and ddPCR in order to assess the efficiency of the RPA compared with the PCR methods. The assays were further applied to the dairy lagoon effluent (DLE) and the high rate algae pond (HRAP) effluent, which were fed with diluted DLE. The RPA detected was <10 CFU/mL, while ddPCR showed quantification from 1 to 104 CFU/mL with a high reproducibility. In addition, quantification by qPCR was from 103 to 107 CFU/mL of the wastewater samples. Therefore, the RPA assay has potential as a point of care tool for the detection of E. coli O157:H7 from different environmental sources, followed by quantification of the target concentrations.


2019 ◽  
Author(s):  
Jiayi Yang ◽  
Boqiang Fu ◽  
Chunyan Niu ◽  
Jing Wang

2010 ◽  
Vol 93 (2) ◽  
pp. 663-675
Author(s):  
Kailin Shen ◽  
Xiang Li ◽  
Shu Wang ◽  
Yingjie Pan ◽  
Zhiyi Shi ◽  
...  

Abstract Despite rapid developments in the detection techniques for genetically modified organisms (GMOs), the event-specific PCR method with high specificity is still the most used technique. In this study, event-specific simplex and duplex qualitative and quantitative detection systems were developed targeting the 3 insertion site of GM maize SYN-E3272-5 (3272) construct. A reference molecule p3272 was constructed to act as positive control and as calibrator for quantitative analysis. The LOD for simplex and duplex qualitative PCR assays was 10 copies of p3272 control DNA. LOD and the LOQ for simplex and duplex quantitative PCR assays were 10 and 25 copies of p3272 DNA, respectively. Furthermore, four practical GM maize samples were quantified using the established simplex and duplex quantitative PCR systems by in-house validation. Results from five operators showed that the bias ranged from 3.44 to 17.24 in the simplex system and from 0.42 to 16.06 in the duplex system, respectively. These results demonstrated that the established event-specific simplex and duplex qualitative and quantitative PCR systems combined with the reference molecule p3272 are suitable for the detection of GM maize 3272 and its derived products.


Sign in / Sign up

Export Citation Format

Share Document