scholarly journals Comparative accuracy of pleural fluid unstimulated interferon-gamma and adenosine deaminase for diagnosing pleural tuberculosis: A systematic review and meta-analysis

PLoS ONE ◽  
2021 ◽  
Vol 16 (6) ◽  
pp. e0253525
Author(s):  
Ashutosh Nath Aggarwal ◽  
Ritesh Agarwal ◽  
Sahajal Dhooria ◽  
Kuruswamy Thurai Prasad ◽  
Inderpaul Singh Sehgal ◽  
...  

Objective We compared diagnostic accuracy of pleural fluid adenosine deaminase (ADA) and interferon-gamma (IFN-γ) in diagnosing tuberculous pleural effusion (TPE) through systematic review and comparative meta-analysis. Methods We queried PubMed and Embase databases to identify studies providing paired data for sensitivity and specificity of both pleural fluid ADA and IFN-γ for diagnosing TPE. We used hierarchical summary receiver operating characteristic (HSROC) plots and HSROC meta-regression to model individual and comparative diagnostic performance of the two tests. Results We retrieved 376 citations and included 45 datasets from 44 publications (4974 patients) in our review. Summary estimates for sensitivity and specificity for ADA were 0.88 (95% CI 0.85–0.91) and 0.91 (95% CI 0.89–0.92), while for IFN-γ they were 0.91 (95% CI 0.89–0.94) and 0.96 (95% CI 0.94–0.97), respectively. HSROC plots showed consistently greater diagnostic accuracy for IFN-γ over ADA across the entire range of observations. HSROC meta-regression using test-type as covariate yielded a relative diagnostic odds ratio of 2.22 (95% CI 1.68–2.94) in favour of IFN-γ, along with better summary sensitivity and specificity figures. No prespecified subgroup variable significantly influenced the summary diagnostic accuracy estimates. Conclusion Pleural fluid IFN-γ estimation has better diagnostic accuracy than ADA estimation for diagnosis of TPE.

2015 ◽  
Vol 53 (8) ◽  
pp. 2451-2459 ◽  
Author(s):  
Ashutosh N. Aggarwal ◽  
Ritesh Agarwal ◽  
Dheeraj Gupta ◽  
Sahajal Dhooria ◽  
Digambar Behera

The role of interferon gamma release assays (IGRAs), although established for identifying latent tuberculosis, is still evolving in the diagnosis of active extrapulmonary tuberculosis. We systematically evaluated the diagnostic performance of blood- and pleural fluid-based IGRAs in tuberculous pleural effusion (TPE). We searched the PubMed and Embase databases for studies evaluating the use of commercially available IGRAs on blood and/or pleural fluid samples for diagnosing TPE. The quality of the studies included was assessed through the QUADAS-2 tool. The pooled estimates of sensitivity and specificity with 95% confidence intervals (95% CI) were generated using a bivariate random-effects model and examined using forest plots and hierarchical summary receiver operating characteristic (HSROC) curves. Indeterminate IGRA results were included for sensitivity calculations. Heterogeneity was explored through subgroup analysis and meta-regression based on prespecified covariates. We identified 19 studies assessing the T.SPOT.TB and/or QuantiFERON assays. There were 20 and 14 evaluations, respectively, of whole-blood and pleural fluid assays, involving 1,085 and 727 subjects, respectively. There was only one good-quality study, and five studies used nonstandard assay thresholds. The pooled sensitivity and specificity for the blood assays were 0.77 (95% CI, 0.71 to 0.83) and 0.71 (95% CI, 0.65 to 0.76), respectively. The pooled sensitivity and specificity for the pleural fluid assays were 0.72 (95% CI, 0.55 to 0.84) and 0.78 (95% CI, 0.65 to 0.87), respectively. There was considerable heterogeneity; however, multivariate meta-regression did not identify any covariate with significant influence. There was no publication bias for blood assays. We conclude that commercial IGRAs, performed either on whole-blood or pleural fluid samples, have poor diagnostic accuracy in patients suspected to have TPE.


Heart ◽  
2020 ◽  
Vol 106 (16) ◽  
pp. 1211-1217 ◽  
Author(s):  
Kam Cheong Wong ◽  
Harry Klimis ◽  
Nicole Lowres ◽  
Amy von Huben ◽  
Simone Marschner ◽  
...  

With increasing use of handheld ECG devices for atrial fibrillation (AF) screening, it is important to understand their accuracy in community and hospital settings and how it differs among settings and other factors. A systematic review of eligible studies from community or hospital settings reporting the diagnostic accuracy of handheld ECG devices (ie, devices producing a rhythm strip) in detecting AF in adults, compared with a gold standard 12-lead ECG or Holter monitor, was performed. Bivariate hierarchical random-effects meta-analysis and meta-regression were performed using R V.3.6.0. The search identified 858 articles, of which 14 were included. Six studies recruited from community (n=6064 ECGs) and eight studies from hospital (n=2116 ECGs) settings. The pooled sensitivity was 89% (95% CI 81% to 94%) in the community and 92% (95% CI 83% to 97%) in the hospital. The pooled specificity was 99% (95% CI 98% to 99%) in the community and 95% (95% CI 90% to 98%) in the hospital. Accuracy of ECG devices varied: sensitivity ranged from 54.5% to 100% and specificity ranged from 61.9% to 100%. Meta-regression showed that setting (p=0.032) and ECG device type (p=0.022) significantly contributed to variations in sensitivity and specificity. The pooled sensitivity and specificity of single-lead handheld ECG devices were high. Setting and handheld ECG device type were significant factors of variation in sensitivity and specificity. These findings suggest that the setting including user training and handheld ECG device type should be carefully reviewed.


2019 ◽  
Vol 55 (1) ◽  
pp. 23-30 ◽  
Author(s):  
Rosa M. Palma ◽  
Silvia Bielsa ◽  
Aureli Esquerda ◽  
Montserrat Martínez-Alonso ◽  
José M. Porcel

BMJ Open ◽  
2018 ◽  
Vol 8 (2) ◽  
pp. e018132 ◽  
Author(s):  
Carmen Phang Romero Casas ◽  
Marrissa Martyn-St James ◽  
Jean Hamilton ◽  
Daniel S Marinho ◽  
Rodolfo Castro ◽  
...  

ObjectivesTo undertake a systematic review and meta-analysis to evaluate the test performance including sensitivity and specificity of rapid immunochromatographic syphilis (ICS) point-of-care (POC) tests at antenatal clinics compared with reference standard tests (non-treponemal (TP) and TP tests) for active syphilis in pregnant women.MethodsFive electronic databases were searched (PubMed, EMBASE, CRD, Cochrane Library and LILACS) to March 2016 for diagnostic accuracy studies of ICS test and standard reference tests for syphilis in pregnant women. Methodological quality was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies). A bivariate meta-analysis was undertaken to generate pooled estimates of diagnostic parameters. Results were presented using a coupled forest plot of sensitivity and specificity and a scatter plot.ResultsThe methodological quality of the five included studies with regards to risk of bias and applicability concern judgements was either low or unclear. One study was judged as high risk of bias for patient selection due to exclusion of pregnant women with a previous history of syphilis, and one study was judged at high risk of bias for study flow and timing as not all patients were included in the analysis. Five studies contributed to the meta-analysis, providing a pooled sensitivity and specificity for ICS of 0.85 (95% CrI: 0.73 to 0.92) and 0.98 (95% CrI: 0.95 to 0.99), respectively.ConclusionsThis review and meta-analysis observed that rapid ICS POC tests have a high sensitivity and specificity when performed in pregnant women at antenatal clinics. However, the methodological quality of the existing evidence base should be taken into consideration when interpreting these results.PROSPERO registration numberCRD42016036335.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Emily MacLean ◽  
Giorgia Sulis ◽  
Claudia M. Denkinger ◽  
James C. Johnston ◽  
Madhukar Pai ◽  
...  

ABSTRACT Invasive collection methods are often required to obtain samples for the microbiological evaluation of children with presumptive pulmonary tuberculosis (PTB). Nucleic acid amplification testing of easier-to-collect stool samples could be a noninvasive method of diagnosing PTB. We conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of testing stool with the Xpert MTB/RIF assay (“stool Xpert”) for childhood PTB. Four databases were searched for publications from January 2008 to June 2018. Studies assessing the diagnostic accuracy among children of stool Xpert compared to a microbiological reference standard of conventional specimens tested by mycobacterial culture or Xpert were eligible. Bivariate random-effects meta-analyses were performed to calculate pooled sensitivity and specificity of stool Xpert against the reference standard. From 1,589 citations, 9 studies (n = 1,681) were included. Median participant ages ranged from 1.3 to 10.6 years. Protocols for stool processing and testing varied substantially, with differences in reagents and methods of homogenization and filtering. Against the microbiological reference standard, the pooled sensitivity and specificity of stool Xpert were 67% (95% confidence interval [CI], 52 to 79%) and 99% (95% CI, 98 to 99%), respectively. Sensitivity was higher among children with HIV (79% [95% CI, 68 to 87%] versus 60% [95% CI, 44 to 74%] among HIV-uninfected children). Heterogeneity was high. Data were insufficient for subgroup analyses among children under the age of 5 years, the most relevant target population. Stool Xpert could be a noninvasive method of ruling in PTB in children, particularly those with HIV. However, studies focused on children under 5 years of age are needed, and generalizability of the evidence is limited by the lack of standardized stool preparation and testing protocols.


BMJ ◽  
2020 ◽  
pp. m2516 ◽  
Author(s):  
Mayara Lisboa Bastos ◽  
Gamuchirai Tavaziva ◽  
Syed Kunal Abidi ◽  
Jonathon R Campbell ◽  
Louis-Patrick Haraoui ◽  
...  

AbstractObjectiveTo determine the diagnostic accuracy of serological tests for coronavirus disease-2019 (covid-19).DesignSystematic review and meta-analysis.Data sourcesMedline, bioRxiv, and medRxiv from 1 January to 30 April 2020, using subject headings or subheadings combined with text words for the concepts of covid-19 and serological tests for covid-19.Eligibility criteria and data analysisEligible studies measured sensitivity or specificity, or both of a covid-19 serological test compared with a reference standard of viral culture or reverse transcriptase polymerase chain reaction. Studies were excluded with fewer than five participants or samples. Risk of bias was assessed using quality assessment of diagnostic accuracy studies 2 (QUADAS-2). Pooled sensitivity and specificity were estimated using random effects bivariate meta-analyses.Main outcome measuresThe primary outcome was overall sensitivity and specificity, stratified by method of serological testing (enzyme linked immunosorbent assays (ELISAs), lateral flow immunoassays (LFIAs), or chemiluminescent immunoassays (CLIAs)) and immunoglobulin class (IgG, IgM, or both). Secondary outcomes were stratum specific sensitivity and specificity within subgroups defined by study or participant characteristics, including time since symptom onset.Results5016 references were identified and 40 studies included. 49 risk of bias assessments were carried out (one for each population and method evaluated). High risk of patient selection bias was found in 98% (48/49) of assessments and high or unclear risk of bias from performance or interpretation of the serological test in 73% (36/49). Only 10% (4/40) of studies included outpatients. Only two studies evaluated tests at the point of care. For each method of testing, pooled sensitivity and specificity were not associated with the immunoglobulin class measured. The pooled sensitivity of ELISAs measuring IgG or IgM was 84.3% (95% confidence interval 75.6% to 90.9%), of LFIAs was 66.0% (49.3% to 79.3%), and of CLIAs was 97.8% (46.2% to 100%). In all analyses, pooled sensitivity was lower for LFIAs, the potential point-of-care method. Pooled specificities ranged from 96.6% to 99.7%. Of the samples used for estimating specificity, 83% (10 465/12 547) were from populations tested before the epidemic or not suspected of having covid-19. Among LFIAs, pooled sensitivity of commercial kits (65.0%, 49.0% to 78.2%) was lower than that of non-commercial tests (88.2%, 83.6% to 91.3%). Heterogeneity was seen in all analyses. Sensitivity was higher at least three weeks after symptom onset (ranging from 69.9% to 98.9%) compared with within the first week (from 13.4% to 50.3%).ConclusionHigher quality clinical studies assessing the diagnostic accuracy of serological tests for covid-19 are urgently needed. Currently, available evidence does not support the continued use of existing point-of-care serological tests.Study registrationPROSPERO CRD42020179452.


2015 ◽  
Vol 53 (12) ◽  
pp. 3738-3749 ◽  
Author(s):  
Caroline Chartrand ◽  
Nicolas Tremblay ◽  
Christian Renaud ◽  
Jesse Papenburg

Respiratory syncytial virus (RSV) rapid antigen detection tests (RADT) are extensively used in clinical laboratories. We performed a systematic review and meta-analysis to evaluate the accuracy of RADTs for diagnosis of RSV infection and to determine factors associated with accuracy estimates. We searched EMBASE and PubMed for diagnostic-accuracy studies of commercialized RSV RADTs. Studies reporting sensitivity and specificity data compared to a reference standard (reverse transcriptase PCR [RT-PCR], immunofluorescence, or viral culture) were considered. Two reviewers independently extracted data on study characteristics, diagnostic-accuracy estimates, and study quality. Accuracy estimates were pooled using bivariate random-effects regression models. Heterogeneity was investigated with prespecified subgroup analyses. Seventy-one articles met inclusion criteria. Overall, RSV RADT pooled sensitivity and specificity were 80% (95% confidence interval [CI], 76% to 83%) and 97% (95% CI, 96% to 98%), respectively. Positive- and negative-likelihood ratios were 25.5 (95% CI, 18.3 to 35.5) and 0.21 (95% CI, 0.18 to 0.24), respectively. Sensitivity was higher in children (81% [95% CI, 78%, 84%]) than in adults (29% [95% CI, 11% to 48%]). Because of this disparity, further subgroup analyses were restricted to pediatric data (63 studies). Test sensitivity was poorest using RT-PCR as a reference standard and highest using immunofluorescence (74% versus 88%;P< 0.001). Industry-sponsored studies reported significantly higher sensitivity (87% versus 78%;P= 0.01). Our results suggest that the poor sensitivity of RSV RADTs in adults may preclude their use in this population. Furthermore, industry-sponsored studies and those that did not use RT-PCR as a reference standard likely overestimated test sensitivity.


Author(s):  
Sneha Sethi ◽  
Xiangqun Ju ◽  
Richard M. Logan ◽  
Paul Sambrook ◽  
Robert A. McLaughlin ◽  
...  

Background: Advances in treatment approaches for patients with oral squamous cell carcinoma (OSCC) have been unsuccessful in preventing frequent recurrences and distant metastases, leading to a poor prognosis. Early detection and prevention enable an improved 5-year survival and better prognosis. Confocal Laser Endomicroscopy (CLE) is a non-invasive imaging instrument that could enable an earlier diagnosis and possibly help in reducing unnecessary invasive surgical procedures. Objective: To present an up to date systematic review and meta-analysis assessing the diagnostic accuracy of CLE in diagnosing OSCC. Materials and Methods. PubMed, Scopus, and Web of Science databases were explored up to 30 June 2021, to collect articles concerning the diagnosis of OSCC through CLE. Screening: data extraction and appraisal was done by two reviewers. The quality of the methodology followed by the studies included in this review was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A random effects model was used for the meta-analysis. Results: Six studies were included, leading to a total number of 361 lesions in 213 patients. The pooled sensitivity and specificity were 95% (95% CI, 92–97%; I2 = 77.5%) and 93% (95% CI, 90–95%; I2 = 68.6%); the pooled positive likelihood ratios and negative likelihood ratios were 10.85 (95% CI, 5.4–21.7; I2 = 55.9%) and 0.08 (95% CI, 0.03–0.2; I2 = 83.5%); and the pooled diagnostic odds ratio was 174.45 (95% CI, 34.51–881.69; I2 = 73.6%). Although risk of bias and heterogeneity is observed, this study validates that CLE may have a noteworthy clinical influence on the diagnosis of OSCC, through its high sensitivity and specificity. Conclusions: This review indicates an exceptionally high sensitivity and specificity of CLE for diagnosing OSCC. Whilst it is a promising diagnostic instrument, the limited number of existing studies and potential risk of bias of included studies does not allow us to draw firm conclusions. A conclusive inference can be drawn when more studies, possibly with homogeneous methodological approach, are performed.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Dawit Gebreegziabiher Hagos ◽  
Henk D. F. H. Schallig ◽  
Yazezew K. Kiros ◽  
Mahmud Abdulkadir ◽  
Dawit Wolday

Abstract Background Visceral Leishmaniasis (VL) is a severely neglected disease affecting millions of people with high mortality if left untreated. In Ethiopia, the primary laboratory diagnosis of VL is by using an antigen from a 39-amino acid sequence repeat of a kinesin-related (rK39) of leishmania donovani complex (L. donovani), rapid diagnostic tests (RDT). Different rk39 RDT brands are available with very variable performance and studies from Ethiopia showed a very wide range of sensitivity and specificity. Therefore, a systematic review and meta-analysis were conducted to determine the pooled sensitivity and specificity of rk39 RDT in Ethiopia. Method PUBMED, EMBASE, and other sources were searched using predefined search terms to retrieve all relevant articles from 2007 to 2020. Heterogeneity was assessed by visually inspecting summary receiver operating curves (SROC), Spearman correlation coefficient (rs), Cochran Q test statistics, inconsistency square (I2) and subgroup analysis. The presence and statistical significance of publication bias were assessed by Egger's test at p < 0.05, and all the measurements showed the presence of considerable heterogeneity. Quality assessment of diagnostic accuracy studies (QUADAS-2) checklists was used to check the qualities of the study. Results A total of 664 articles were retrieved, and of this 12 articles were included in the meta-analysis. Overall pooled sensitivity and specificity of the rk39 RDT to diagnose VL in Ethiopia were 88.0% (95% CI 86.0% to 89.0%) and 84.0% (95% CI 82.0% to 86.0%), respectively. The sensitivity and specificity of the rk39 RDT commercial test kits were DiaMed: 86.9% (95% CI 84.3% to 89.1%) and 82.2% (95% CI 79.3% to 85.0%), and InBios: 80.0% (95% CI 77.0% to 82.8%) and 97.4% (95% CI 95.0% to 98.8%), respectively. Conclusion Referring to our result, rk39 RDT considered an essential rapid diagnostic test for VL diagnosis. Besides to the diagnostic accuracy, the features such as easy to perform, quick (10–20 min), cheap, equipment-free, electric and cold chain free, and result reproducibility, rk39 RDT is advisable to remains in practice as a diagnostic test at least in the remote VL endemic localities till a better test will come.


Sign in / Sign up

Export Citation Format

Share Document