scholarly journals Evaluation of marginal fit and microleakage of monolithic zirconia crowns cemented by bio-active and glass ionomer cements: In vitro study

2020 ◽  
Vol 23 (1) ◽  
Author(s):  
Radwa Hamdy Aboelenen ◽  
Ashraf Mokhtar ◽  
Hanaa Zaghloul

Objective: To evaluate the marginal fit and microleakage of monolithic zirconia crowns cemented with bioactive cement (Ceramir) compared to that cemented with glass ionomer cement and to evaluate the effect of thermocycling on marginal fit. Materials and methods: Twenty sound human molar teeth were prepared to receive a monolithic zirconia crowns. Teeth were divided randomly into two equal groups according to the type of luting cement. Group I: glass ionomer cement and group II: Ceramir cement. After cementation, the vertical marginal gap was assessed by using stereomicroscope before and after thermocycling. Twenty equidistant measurement points were taken for each crown. Leakage assessment was carried out using Fuchsin dye penetration followed by digital photography under a stereomicroscope. Data were analyzed by Mann-Whitney U test to compare between the two luting cements. Wilcoxon signed-rank test was used to evaluate the effect of thermocycling on the marginal fit (P ≤ 0.05)
Results: Whether before or after thermocycling, the results showed no significant difference between the marginal gap values of the two tested groups. For both groups, there was a significant increase in marginal gap values after thermocycling. Also, there was no significant difference between leakage scores of the two tested groups. Conclusions: Similarity in the physical properties and chemical composition of the two cements result in a non- significant effect on the vertical marginal fit and the extent of microleakage of translucent zirconia crowns.  Thermocycling had a negative impact on the vertical marginal gap of the two tested luting agents.

2018 ◽  
Vol 14 (1) ◽  
pp. 24
Author(s):  
Dr. Sazan Sherdil Saleem

The present study was aimed to evaluate and compare the compressive strength ofconventional glass ionomer cement with resin modified glass ionomer, compomer andmicrohybrid composite. A total of 40 specimens of esthetic restorative materials werefabricated using customized cylindrical teflon mould measuring 6mm height and 4mmdiameter and were grouped with ten specimens in each group, Group I: Conventionalglass ionomer cement (Fuji II). Group II: Resin modified glass ionomer (Fuji II LC).Group III: Compomer (Dyract AP) and Group IV: Microhybrid composite resin(Tetric Ceram).They were covered with Mylar strip and were cured using LED lightcuring unit. Compressive strength was evaluated using Universal testing machine. Theresult showed that there were a significant difference among the groups in whichTetric Ceram showed highest compressive strength and Fuji II showed the leastcompressive strength


2010 ◽  
Vol 35 (2) ◽  
pp. 157-161 ◽  
Author(s):  
Sajad Sainulabdeen ◽  
Prasanna Neelakantan ◽  
Sindhu Ramesh ◽  
CV Subbarao

Objectives: The aim of this pilot study was to evaluate the antibacterial activity of glass ionomer cement impregnated with different concentrations (0.5%, 1.25% and 2.5%) of a non releasing bactericide –Triclosan (TC) against two common cariogenic bacteria – Lactobacillus acidophilus and Streptococcus mutans; and to compare Triclosan incorporated GIC with chlorhexidine (CHX) incorporated GIC (2.5%)in terms of antibacterial activity. Methods: Chlorhexidine or Triclosan were added to glass ionomer cement powder to achieve 2.5% CHX – GIC (positive control – Group II), 0.5%, 1.25% and 2.5% TC-GIC (experimental groups III, IV and V respectively) formulations. Restorative glass ionomer cement (Fuji IX GC –Group I) served as negative control. The powder and liquid were mixed and inserted into the wells punched in agar plates (10mm × 4mm). The agar diffusion method was used to determine the antibacterial activity of the cements after 1, 7 and 30 days. Mean values were compared between different study groups using One-way ANOVA and Tukey's HSD procedure at a significance level of 5%. Results: Triclosan incorporated GIC was more effective against L.acidophilus and S.mutans than Chlorhexidine incorporated GIC. Triclosan at a concentration of 2.5% was more effective than at lower concentrations. At all time periods studied, the maximum zone of inhibition against L.acidophilus was produced by Group V. Against S.mutans, on days 1,7 and 30, there was no significant difference between Groups II and IV (p>0.05), while the other groups showed significant differences. Conclusion: The use of triclosan as an antibacterial additive in GIC holds promise and further clinical research is needed in this direction.


2003 ◽  
Vol 9 (1-2) ◽  
pp. 201-207 ◽  
Author(s):  
F. Saleh ◽  
N. Taymour

Shear and tensile bond strengths of 40 human and 40 bovine teeth were compared. Teeth were randomly assigned to group I, which received light-cured composite resin, or group II, which received light-cured resin-reinforced glass ionomer cement. The groups were subdivided for shear and tensile bond strength tests, which were conducted on a universal testing machine installed to a computer transducer. Statistical analysis revealed a highly significant difference between shear and tensile bond strengths of human and bovine enamel; however, regression prediction equations support the use of bovine teeth as a reliable substitute to human counterparts in bonding studies of orthodontic adhesion


2020 ◽  
Vol 23 (3) ◽  
Author(s):  
Mohamed Eldamaty ◽  
Mohammed Abdel-Aziz ◽  
Ahmed El-Kouedi ◽  
Tamer Hamza

Objective: The purpose of this study was to evaluate the effect of finish line design and cement space thickness on the marginal accuracy of monolithic zirconia crowns. Materials and methods: Thirty crowns were fabricated from translucent zirconia (inCoris TZI) using Cerec in-Lab system and divided into three main groups (10 each) according to the finish line type of the die (knife-edge, chamfer, and shoulder). Every group was divided into two subgroups (5 each) according to cement space thickness (20 and50μm). Optical impressions were taken for the dies using the Cerec scanner and cement space was set twice for every finish line design; 20 and 50 μm. The completed crowns were cemented to the dies and the marginal gap was evaluated. The collected data was statistically analyzed using Mann-Whitney U test and Kruskal-Wallis test and the significance level was set at P ≤ 0.05. Results: Regarding the marginal gap; there was no statistically significant difference between different finish line designs or between different cement space thicknesses. Conclusion: Neither finish line design nor cement space thickness has an effect on the marginal gap of inCoris TZI crowns.KeywordsCement space; Finish line; Marginal fit; Monolithic zirconia.


2020 ◽  
pp. 38-45
Author(s):  
Duong Nguyen Thi Thuy ◽  
Huong Nguyen Thi Kim

Background: Composite and Glass ionomer cement (GIC) are common restorative materials of non carious cervical lesions (NCCLs), which effects are controverisial. The aim of the present study was to compare the result of restorations on NCCLs between Composite and GIC. Materials and Methods: follow-up clinical trial with split-mouth design. Thirty-six patients with 96 NCCLs were divided into 2 groups (n=48/group): Group 1 restored by Composite, Group 2 restored by GIC. The restorations were evaluated at baseline, 1 and 3 months for pulpal sensitivity, restoration morphology and overall success grade. Results: GIC restorations gained 100% Good results for all parameters at 3 time points. Composite showed 87.5%, 93.8% and 97.9% Good results at baseline, 1 and 3 months, sequentially. At 3 weeks recall, 1 Composite restorations (2.1%) showed Moderate results of Retention and 2 Composite restorations (4.2%) changed colour. Conclusions: There was no statistically significant difference seen among the three groups for 3 parameters. Key words: non-carious cervical lesion, Composite, Glass ionomer cement


2001 ◽  
Vol 15 (4) ◽  
pp. 277-282 ◽  
Author(s):  
Maria Fernanda Borro BIJELLA ◽  
Maria Francisca Thereza Borro BIJELLA ◽  
Salete Moura Bonifácio da SILVA

This study evaluated, in vitro, marginal microleakage in class II restorations confected with the glass ionomer cement Vitremer and with the composite resins Ariston pHc and P-60. The aims of the study were to assess the effect of thermocycling on those materials and to evaluate two methods utilized in the analysis of dye penetration. Sixty premolars divided in three groups were utilized; the teeth had proximal cavities whose cervical walls were located 1 mm below the cementoenamel junction. Half of the test specimens from each group underwent thermocycling; the other half remained in deionized water, at 37ºC. The specimens were immersed, for 24 hours, in a basic 0.5% fuchsin solution at 37ºC. For the analysis of microleakage, the specimens were sectioned in a mesio-distal direction, and the observation was carried out with the software Imagetools. The results were evaluated through the 2-way ANOVA and through the Tukey’s test. All groups presented marginal microleakage. The smallest values were obtained with Vitremer, followed by those obtained with the composite resins P-60 and Ariston pHc. There was no statistically significant difference caused by thermocycling, and the method of maximum infiltration was the best for detecting the extension of microleakage.


2006 ◽  
Vol 20 (2) ◽  
pp. 91-96 ◽  
Author(s):  
Mônica Tostes Amaral ◽  
Antônio Carlos Guedes-Pinto ◽  
Orlando Chevitarese

This work evaluated the remineralization of demineralized enamel of pits and fissures of human third molars sealed with a glass ionomer cement (Fuji IX, GC Corporation - Japan) or with a Bis-GMA sealant (Delton - Dentsply). Ten volunteers participated in this in situ study that consisted of two thirty-day periods using intra-oral devices, with a week’s interval in between. Four experimental treatment procedures and one control were randomly assigned to the volunteers’ specimens: Group I, no treatment, control; Group II, artificial caries process; Group III, same treatment as Group II, but sealed with Delton (Dentsply); Group IV, same treatment as Group II, but sealed with Fuji IX (GC Corporation - Japan); Group V, same treatment as Group II and no sealing. Groups I and II were not submitted to the oral environment and served as controls. After a period of 30 days in the oral environment, the specimens were removed from the devices, embedded in acrylic resin, ground flat and polished. Then, Knoop hardness tests were performed, with a 25 g static load applied for 15 seconds. The measurements were made from the base of the fissure up to an opening of 600 µm, pre-established between the inclines of the cusps. Three indentations were then made, located at 25, 75, and 125 µm in depth from the outer enamel margin and 100 µm apart from each other (Micromet 2003). The Brieger F and Bonferroni’s tests were applied to the measurements. It was concluded that sealing with the glass ionomer cement Fuji IX was capable of making the enamel of pits and fissures more resistant by increasing the value of Knoop hardness.


2018 ◽  
Vol 29 (2) ◽  
pp. 128-132 ◽  
Author(s):  
Gabriela Cristina Santin ◽  
Alexandra Mussolino de Queiroz ◽  
Regina Guenka Palma-Dibb ◽  
Harley Francisco de Oliveira ◽  
Paulo Nelson Filho ◽  
...  

Abstract Patients undergoing radiotherapy treatment present more susceptibility to dental caries and the use of an orthodontic device increases this risk factor due to biofilm accumulation around the brackets. The objective of this study was to evaluate the shear bond strength to irradiated permanent teeth of orthodontic brackets bonded with conventional glass ionomer cement and resin-modified glass ionomer cement due to the fluoride release capacity of these materials. Ninety prepared human premolars were divided into 6 groups (n=15), according to the bonding material and use or not of radiation: CR: Transbond XT composite resin; RMGIC: Fuji Ortho LC conventional glass ionomer cement; GIC: Ketac Cem Easymix resin-modified glass ionomer cement. The groups were irradiated (I) or non-irradiated (NI) prior to bracket bonding. The specimens were subjected to a fractioned radiation dose of 2 Gy over 5 consecutive days for 6 weeks. After the radiotherapy, the brackets were bonded on the specimens with Transbond XT, Fuji Ortho LC and Ketac Cem Easymix. After 24 h, the specimens were subjected to shear bond strength test. The image of enamel surface (classified by Adhesive Remnant Index - ARI) was also evaluated and its frequency was checked among groups/subgroups. The shear bond strength variable was evaluated with ANOVA and Tukey’s post-hoc test. GIC group showed the lowest adhesion values among the groups (p<0.05). There was no statistically significant difference among non-irradiated and irradiated groups (p>0.05). As for the ARI, the CR-I group showed the highest material retention on enamel surface among the irradiated groups. RMGIC group showed the highest values for shear bond strength and presented ARI acceptable for clinical practices.


2010 ◽  
Vol 2010 ◽  
pp. 1-6 ◽  
Author(s):  
Sabine O. Geerts ◽  
Laurence Seidel ◽  
Adelin I. Albert ◽  
Audrey M. Gueders

This study was designed to evaluate microleakage that appeared on Resin-Modified Glass-Ionomer Cement (RMGIC) restorations. Sixty class V cavities () were cut on thirty extracted third molars, which were randomly allocated to three experimental groups. All the buccal cavities were pretreated with polyacrylic acid, whereas the lingual cavities were treated with three one-step Self-Etch adhesives, respectively, Xeno III (Dentsply Detrey GmbH, Konstanz, Germany), iBond exp (Heraeus Kulzer gmbH & Co. KG, Hanau, Germany), and Adper Prompt-L-Pop (3M ESPE AG, Dental products Seefeld, Germany). All cavities were completely filled with RMGIC, teeth were thermocycled for 800 cycles, and leakage was evaluated. Results were expressed as means standard deviations (SDs). Microleakage scores were analysed by means of generalized linear mixed models (GLMMs) assuming an ordinal logistic link function. All results were considered to be significant at the 5% critical level (). The results showed that bonding RMGIC to dentin with a Self-Etch adhesive rather than using polyacrylic acid did not influence microleakage scores (), except for one tested Self-Etch adhesive, namely, Xeno III (). Nevertheless, our results did not show any significant difference between the three tested Self-Etch adhesive systems. In conclusion, the pretreatment of dentin with Self-Etch adhesive system, before RMGIC filling, seems to be an alternative to the conventional Dentin Conditioner for the clinicians as suggested by our results (thermocycling) and others (microtensile tests).


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


Sign in / Sign up

Export Citation Format

Share Document