scholarly journals Biomedical Arrhythmia Heart Diseases Classification Based on Artificial Neural Network and Machine Learning Approach

2018 ◽  
Vol 7 (3.27) ◽  
pp. 10 ◽  
Author(s):  
Stalin Subbiah ◽  
Suresh Subramanian

In present day, several types of developments are carried toward the medical application.  There has been increased improvement in the processing of ECG signals. The accurate detection of ECG signals with the help of detection of P, Q, R and S waveform. However these waveforms are suffered from some disturbances like noise.  Initially denoising the ECG signal using filters and detect the PQRS waveforms. Four filters are carried out to remove the ECG noises that are Median, Gaussian, FIR and Butterworth filter. ECG signal is analyzed or classify using Extreme Learning Machine (ELM) and it compared with Support Vector Machine (SVM) and Back Propagation Neural Network (BPNN). The paper classifies the ECG signal into two classes, Normal and Abnormal. ECG waveform is detected and analyzed using the 48 records of the MIT-BIH arrhythmia database. Denoising results are evaluated using MSE, RMSE, PSNR, NAE and NCC. The classifier performance is measured in terms of Sensitivity (Se), Positive Predictivity (PP) and Specificity (SP).   

Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 660 ◽  
Author(s):  
Fang Liu ◽  
Liubin Li ◽  
Yongbin Liu ◽  
Zheng Cao ◽  
Hui Yang ◽  
...  

In real industrial applications, bearings in pairs or even more are often mounted on the same shaft. So the collected vibration signal is actually a mixed signal from multiple bearings. In this study, a method based on Hybrid Kernel Function-Support Vector Regression (HKF–SVR) whose parameters are optimized by Krill Herd (KH) algorithm was introduced for bearing performance degradation prediction in this situation. First, multi-domain statistical features are extracted from the bearing vibration signals and then fused into sensitive features using Kernel Joint Approximate Diagonalization of Eigen-matrices (KJADE) algorithm which is developed recently by our group. Due to the nonlinear mapping capability of the kernel method and the blind source separation ability of the JADE algorithm, the KJADE could extract latent source features that accurately reflecting the performance degradation from the mixed vibration signal. Then, the between-class and within-class scatters (SS) of the health-stage data sample and the current monitored data sample is calculated as the performance degradation index. Second, the parameters of the HKF–SVR are optimized by the KH (Krill Herd) algorithm to obtain the optimal performance degradation prediction model. Finally, the performance degradation trend of the bearing is predicted using the optimized HKF–SVR. Compared with the traditional methods of Back Propagation Neural Network (BPNN), Extreme Learning Machine (ELM) and traditional SVR, the results show that the proposed method has a better performance. The proposed method has a good application prospect in life prediction of coaxial bearings.


2011 ◽  
Vol 11 (04) ◽  
pp. 897-915 ◽  
Author(s):  
ROSHAN JOY MARTIS ◽  
CHANDAN CHAKRABORTY

This work aims at presenting a methodology for electrocardiogram (ECG)-based arrhythmia disease detection using genetic algorithm (GA)-optimized k-means clustering. The open-source ECG data from MIT-BIH arrhythmia database and MIT-BIH normal sinus rhythm database are subjected to a sequence of steps including segmentation using R-point detection, extraction of features using principal component analysis (PCA), and pattern classification. Here, the classical classifiers viz., k-means clustering, error back propagation neural network (EBPNN), and support vector machine (SVM) have been initially attempted and subsequently m-fold (m = 3) cross validation is used to reduce the bias during training of the classifier. The average classification accuracy is computed as the average over all the three folds. It is observed that EBPNN and SVM with different order polynomial kernel provide significant accuracies in comparison with k-means one. In fact, the parameters (centroids) of k-means algorithm are locally optimized by minimizing its objective function. In order to overcome this limitation, a global optimization technique viz., GA is suggested here and implemented to find more robust parameters of k-means clustering. Finally, it is shown that GA-optimized k-means algorithm enhances its accuracy to those of other classifiers. The results are discussed and compared. It is concluded that the GA-optimized k-means algorithm is an alternate approach for classification whose accuracy will be near to that of supervised (viz., EBPNN and SVM) classifiers.


Author(s):  
Khudhur A. Alfarhan ◽  
Mohd Yusoff Mashor ◽  
Abdul Rahman Mohd Saad ◽  
Mohammad Iqbal Omar

Heart monitoring kits are only available for bedridden patients and the traditional heart monitoring kits have many wires that are obstacle patients’ mobility. Most of the existing heart monitoring kits can not detect heart diseases. Thus, the current study proposed a wireless heart monitoring kit to monitor patients with a heart abnormality. The proposed kit can detect and classify four arrhythmia types as well as normal ECG with high accuracy. The design and development of the wireless heart abnormality monitoring kit (WHAMK) in this research were divided into three stages. These stages are the development of an arrhythmias detection and classification method using artificial intelligence approach, design and implementation of the kit hardware, and design and coding of the kit software. Arrhythmias classification approach is divided into four stages, namely obtaining the electrocardiograph (ECG) signals, preprocessing, features extraction and classification. The features extraction method are based on statistical features. The library support vector machine (LIBSVM) was used to classify the ECG signals. The hardware of the kit is divided into two parts, namely ECG body sensor (EBS), and processing and displaying unit (PDU). EBS working on acquiring the ECG signal from patient's body. PDU working on processing the collected ECG signal, plotting it and detecting the arrhythmias. Arrhythmias classification approach was developed by using statistical features and LIBSVM. They were implemented in the software of the kit to enable it to detect the arrhythmias in the real-time and fully automatically. The kit can detect and classify four arrhythmia types as well as normal sinus rhythm (NSR). These types of arrhythmia are premature atrial contraction (PAC), premature ventricles contraction (PVC), Bradycardia and Tachycardia. The proposed kit gave a good accuracy for detecting and classifying Arrhythmia with the overall accuracy of 96.2%.


Sign in / Sign up

Export Citation Format

Share Document