Capabilities and incapabilities of unity power factor control algorithm for DSTATCOM under abnormal grid and load conditions

2022 ◽  
Vol 15 (1) ◽  
pp. 55
Author(s):  
Yogesh Rohilla ◽  
Dinesh Kumar ◽  
Bharat Singh Rajpurohit
2011 ◽  
Vol 347-353 ◽  
pp. 2227-2230 ◽  
Author(s):  
Shu Xi Liu ◽  
Shan Li ◽  
Juan He

Direct-driven permanent magnet synchronous generator (PMSG) has become an important research subject besides the double-fed induction generator. With the increasing of unit capacity, the study of topology of high power converters based on multi-level converter is attracting more and more attention. The study of vector control of the direct-driven permanent magnet synchronous wind turbines based on three-level converter is carried out in this paper. Based on the maximum wind-energy capture control of the PMSG, the unity power factor operation of PMSG is realized by controlling the d-axis current to zero in the generator-side converter. A detailed comparative study of two-level system and three-level system is conducted. The simulation results verify the validity of this algorithm.


Author(s):  
Saidah Saidah ◽  
Hari Sutiksno ◽  
Bambang Purwahyudi ◽  
Taufik Taufik

This paper introduces the modelling of a novel three phase AC-AC converter with indirect use of a capacitor as DC voltage link. The proposed converter has high efficiency because it uses Space Vector PWM (SVPWM) technique at both rectificier and inverter stages to operate the pulse width modulation in IGBT switches. The novel converter is equipped with a power factor control to shape the rectifier input current waveform to be sinusoidal and to be in phase with the input voltage. To keep the DC voltage stable, the converter utilizes PI controllers. Simulations are conducted for output voltage from 120 to 300 Volts with output frequency ranging from 30 Hz to 60 Hz. The simulation results show that the converter is able to maintain stable the DC voltage and current. Furthermore, the model demonstrates the benefits of proposed converter in terms of acquiring high input power factor and sinusoidal current waveform at the output side of the inverter.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 1295-1303
Author(s):  
Dezhi Chen ◽  
Chengwu Diao ◽  
Zhiyu Feng ◽  
Shichong Zhang ◽  
Wenliang Zhao

This paper presents the performance of open-winding permanent magnet synchronous motor (OW-PMSM). It mainly includes vector modulation technology considering the unity power factor control.And a topology structure is proposed to optimize the fault tolerance of inverter. Matlab software and Maxwell software collaborative simulation are supplied to obtain the reactive power, speed, terminal voltage, electromagnetic torque etc. under normal and fault status. Finally, the simulation results of an open-winding permanent magnet synchronous motor are verified by the experimental results.


Electronics ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1427 ◽  
Author(s):  
Jae-Chang Kim ◽  
Dongyeon Kim ◽  
Sang-Shin Kwak

In a current source rectifier such as a matrix rectifier, input voltage and current cannot be in phase unless an additional input power factor control technique is implemented. This paper proposes such a technique for a matrix rectifier using power-based space vector modulation (SVM). In the proposed method, the modulation index and phase required in order to apply the SVM are calculated based on the active and reactive power of the rectifier for intuitive power factor control. The active power that the rectifier should generate for the regulation of the output inductor current is obtained by the PI (proportional-integral) controller. The reactive power, which is supplied by the rectifier for adjustment of the power factor, is assigned differently depending on the output condition: for the output condition capable of unity power factor, it is set to a negative value of reactive power of the input capacitor, and when the unity power factor is not achievable, it is set with the maximum reactive power the rectifier can generate under the given condition to attain the maximum possible input power factor. It is determined whether the given condition is the light load condition by comparing the absolute value of the reactive power supplied by the input capacitor with the maximum rectifier reactive power that can be produced under the given condition. The SVM based on the active and reactive power of the rectifier in this technique allows the input power factor control to be intuitive and simple. The performance and feasibility of the technique were proved by simulation and experimentation.


Sign in / Sign up

Export Citation Format

Share Document