scholarly journals Water Quality Correction Within Water Distribution System

2015 ◽  
Vol 22 (3) ◽  
pp. 401-410 ◽  
Author(s):  
Dariusz Kowalski ◽  
Beata Kowalska ◽  
Ewa Hołota ◽  
Artur Choma

Abstract Water suppliers can be treated as production companies whose main product is water delivered to their customers. The article presents problems connected with management of such companies in the conditions of secondary contamination in water distribution systems. This phenomenon exists in water networks all over the world. Its’ presence is particularly visible in countries of former communistic block. In the article particular attention was devoted to the issue of water quality correction in the analysed systems. In the case of water distribution systems, former quality correction methods consisted in special treatment of water pumped into the system, flushing and cleaning of water pipes. In both these cases identification of water quality deficiencies resulted in significant water loss. The situation reflects management processes applied in the manufacturing industry of the 1940s. The authors of this paper put forward the concept of three water quality correction methods which would not entail such considerable water loss. The methods in question are intended for different network types. The implementation of proposed solutions could set new standards in management of distribution systems of water providers.

2013 ◽  
Vol 14 (1) ◽  
pp. 81-90 ◽  
Author(s):  
W. R. Furnass ◽  
R. P. Collins ◽  
P. S. Husband ◽  
R. L. Sharpe ◽  
S. R. Mounce ◽  
...  

The erosion of the cohesive layers of particulate matter that causes discolouration in water distribution system mains has previously been modelled using the Prediction of Discolouration in Distribution Systems (PODDS) model. When first proposed, PODDS featured an unvalidated means by which material regeneration on pipe walls could be simulated. Field and laboratory studies of material regeneration have yielded data that suggest that the PODDS formulations incorrectly model these processes. A new model is proposed to overcome this shortcoming. It tracks the relative amount of discolouration material that is bound to the pipe wall over time at each of a number of shear strengths. The model formulations and a mass transport model have been encoded as software, which has been used to verify the model's constructs and undertake sensitivity analyses. The new formulations for regeneration are conceptually consistent with field and laboratory observed data and have potential value in the proactive management of water distribution systems, such as evaluating change in discolouration risk and planning timely interventions.


Resources ◽  
2019 ◽  
Vol 8 (4) ◽  
pp. 162 ◽  
Author(s):  
Barbara Tchórzewska-Cieślak ◽  
Katarzyna Pietrucha-Urbanik ◽  
Dorota Papciak

Given that a consequence of a lack of stability of the water in a distribution system is increased susceptibility to secondary contamination and, hence, a threat to consumer health, in the work detailed here we assessed the risk of such a system experiencing quality changes relating to the biological and chemical stability of water intended for drinking. Utilizing real operational data from a water treatment station, the presented analysis of the stability was performed based on the fault tree method. If they are to protect their critical-status water supply infrastructure, water supply companies should redouble their efforts to distribute stable water free of potentially corrosive properties. To that end, suggestions are made on the safeguarding of water distribution systems, with a view to ensuring the safety of operation and the long-term durability of pipes.


2018 ◽  
Vol 4 (12) ◽  
pp. 2080-2091 ◽  
Author(s):  
Isabel Douterelo ◽  
Carolina Calero-Preciado ◽  
Victor Soria-Carrasco ◽  
Joby B. Boxall

This research highlights the potential of whole metagenome sequencing to help protect drinking water quality and safety.


2012 ◽  
Vol 12 (5) ◽  
pp. 580-587 ◽  
Author(s):  
Stephen Mounce ◽  
John Machell ◽  
Joby Boxall

Safe, clean drinking water is a foundation of society and water quality monitoring can contribute to ensuring this. A case study application of the CANARY software to historic data from a UK drinking water distribution system is described. Sensitivity studies explored appropriate choice of algorithmic parameter settings for a baseline site, performance was evaluated with artificial events and the system then transferred to all sites. Results are presented for analysis of nine water quality sensors measuring six parameters and deployed in three connected district meter areas (DMAs), fed from a single water source (service reservoir), for a 1 year period and evaluated using comprehensive water utility records with 86% of event clusters successfully correlated to causes (spatially limited to DMA level). False negatives, defined by temporal clusters of water quality complaints in the pilot area not corresponding to detections, were only approximately 25%. It was demonstrated that the software could be configured and applied retrospectively (with potential for future near real time application) to detect various water quality event types (with a wider remit than contamination alone) for further interpretation.


Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 553 ◽  
Author(s):  
Young Choi ◽  
Joong Kim

This study proposes a multi-objective optimal design approach for water distribution systems, considering mechanical system redundancy under multiple pipe failure. Mechanical redundancy is applied to the system’s hydraulic ability, based on the pressure deficit between the pressure requirements under abnormal conditions. The developed design approach shows the relationships between multiple pipe failure states and system redundancy, for different numbers of pipe-failure conditions (e.g., first, second, third, …, tenth). Furthermore, to consider extreme demand modeling, the threshold of the demand quantity is investigated simultaneously with multiple pipe failure modeling. The design performance is evaluated using the mechanical redundancy deficit under extreme demand conditions. To verify the proposed design approach, an expanded version of the well-known benchmark network is used, configured as an ideal grid-shape, and the multi-objective harmony search algorithm is used as the optimal design approach, considering construction cost and system mechanical redundancy. This optimal design technique could be used to propose a standard for pipe failure, based on factors such as the number of broken pipes, during failure condition analysis for redundancy-based designs of water distribution systems.


2003 ◽  
Vol 3 (1-2) ◽  
pp. 239-246 ◽  
Author(s):  
G. Kastl ◽  
I. Fisher ◽  
V. Jegatheesan ◽  
J. Chandy ◽  
K. Clarkson

Nearly all drinking water distribution systems experience a “natural” reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the “optimum level”, considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne’s Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water’s Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.


Sign in / Sign up

Export Citation Format

Share Document