scholarly journals Comparison of cyclic fatigue resistance of XP-endo Shaper, HyFlex CM, FlexMaster and Race instruments

2018 ◽  
Vol 12 (3) ◽  
pp. 208-212 ◽  
Author(s):  
Mehmet Adiguzel ◽  
Ipek Isken ◽  
Ismail Ilker Pamukcu

Background. The aim of this study was to compare the cyclic fatigue resistance of XP-endo Shaper, HyFlex CM, FlexMaster and Race rotary instruments at body temperature (37±1°C). Methods. Twenty XP-endo Shaper (#30/.01), 20 HyFlex CM (#30/.04), 20 FlexMaster (#30/.04) and 20 Race (#30/.04) instruments were tested at body temperature (n=20). The instruments were evaluated in artificial canals with a 3-mm radius of curvature and 60° angle of curvature to the center of the 1.5-mm-wide canal. Each instrument was rotated until fracture occurred and the number of cycles to failure (NCF) recorded. Data were analyzed using one-way ANOVA and Tukey HSD tests (P<0.05). Results. The difference in the NCF of all the instruments was statistically significant (P<0.05). The order of the instruments from the highest to the lowest NCF was as follows: XP-endo Shaper (3064.0±248.1), HyFlex CM (1120.5±106.1), FlexMaster (569.8±48.4) and Race (445.5±53.5). Conclusion. Under the limitations of the present study, XP-endo Shaper instruments were more resistant to cyclic fatigue than the #30/.04 nickel-titanium rotary instruments immersed in water at simulated body temperature.

2018 ◽  
Vol 12 (4) ◽  
pp. 283-287 ◽  
Author(s):  
Gülşah Uslu ◽  
Taha Özyürek ◽  
Mustafa Gündoğar ◽  
Koray Yılmaz

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.


2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Hind F. Abuhulaibah ◽  
Ammar AbuMostafa

Background/purpose. To assess the resistance to cyclic fatigue (CF) displayed by two nickel-titanium (NiTi) files, One Curve (OC) and ProTaper Gold (PTG), after their immersion in 2.5% sodium hypochlorite (NaOCl) solution at body temperature. Materials and Methods. Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel artificial canal in a water bath at 37°C simulating body temperature. The procedure was video recorded, and the number of cycles to fracture (NCF) was calculated by multiplying the time taken to fracture, with the number of rotations per second. The data were analyzed for normality, and thereafter, one-way ANOVA with multiple Bonferroni was used as the post hoc test. Results. The resistance to CF of OC files was significantly higher than PTG files in all groups. In groups immersed in NaOCl for one minute, OC files showed significant drop in the CF resistance; PTG files showed a drop as well but not significantly. Both files demonstrated a significant drop in resistance to CF after immersion in NaOCl for five minutes compared to the control group. Conclusion. OC files were significantly more resistant to CF compared to PTG in all groups. Immersion in 2.5% NaOCl for 5 minutes significantly reduced the resistance to CF for all the files.


2021 ◽  
Vol 25 (2) ◽  
pp. 87-91
Author(s):  
Neslihan Büşra Keskin ◽  
Gürkan Güneç

Summary Background/Aim: The aim of the present study was to compare the cyclic fatigue resistance of NiTi files running with reciprocal motion and having different characteristics (RPC Blue, WOG, EndoArt Wise Reciproc Gold, EndoArt Wise Reciproc Blue) at the intracanal temperature (35°C) by using NaOCl irrigation solution. Material and Methods: Totally 60 WaveOne GOLD (Dentsply-Sirona, Ballaigues, Switzerland), Reciproc Blue (VDW, Munich, Germany), EndoArt Wise Reciproc Gold, and EndoArt Wise Blue (Inci Dental Productions Co, Istanbul, Turkey) (n= 15) files were used. Each of the rotary files were tested at the intracanal temperature (35°C) using a dynamic model in a stainless-steel artificial canal with an inner diameter of 1.5 mm, 60° angle of curvature, and 2mm radius of curvature until fracture occurred. The device automatically stopped at the moment of fracture and the number of cycles to the fracture was calculated as per second. The lengths of fractured parts were measured using a digital microcaliper. The One-Way Analysis of Variance (ANOVA) and Tukey’s post-hoc tests were used for intergroup comparisons. Results: In 2 mm Radius of curvature, the EndoArt Wise Reciproc Blue group had a significantly higher time to fracture followed by the EndoArt Wise Reciproc Gold, Resiproc Blue, WaveOne Gold. No significant difference was found between EndoArt Wise Reciproc Gold and Resiproc Blue groups (P>0.05). Among the groups, there was no statistically significant difference in the lengths of fractured parts of the instruments (P> 0.05). Conclusions: EndoArt Wise Reciproc Blue files exhibited significantly higher cyclic fatigue resistance compared with other files tested in a 2-mm radius of curvature and a 60° angle in an artificial canal at the intracanal temperature.


2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
Abdullah Mahmoud Riyahi ◽  
Amr Bashiri ◽  
Khalid Alshahrani ◽  
Saad Alshahrani ◽  
Hadi M. Alamri ◽  
...  

TruNatomy (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) is a newly released system that was not tested in any previous studies. The objective of this work is to evaluate cyclic fatigue resistance of the new file and compare it with the Twisted Files (TF) and ProTaper Next (PTN). Forty-five files were distributed into 3 groups: PTN X2 (size 25 and taper 0.06), TF (size 25 and taper 0.06), and TN prime file (size 26 and taper 0.04). Each group included 15 files. Lengths of all files were 25 mm. Cyclic fatigue testing was done using artificial stainless-steel canals with 60-degree curvature and 5 mm radius. Continuous rotation movement at 300 rpm was used until the file fractures. Time for file separation was recorded in seconds. The number of cycles to failure (NCF) mean and standard deviation for each group was calculated. For statistical analysis of data, ANOVA and Tukey’s multiple comparison test were used. Mean and standard deviation (SD) of NCF were 259 ± 37.2, 521.67 ± 63.07 and 846.67 ± 37.16 for PTN, TF, and TN respectively. TN on average had significantly the highest NCF compared with PTN (p<0.05) and TF (p<0.05). TruNatomy file showed superior cyclic fatigue resistance. With its potential to preserve tooth structure, this file offers a good cyclic fatigue advantage. However, future studies are required to evaluate other properties of this file and to examine its clinical performance.


2021 ◽  
Author(s):  
Mohammad Al-Obaida ◽  
Khalid Merdad ◽  
Ali Alkhamis ◽  
Muneer Khan Mohammed ◽  
Rahaf Al-Obaida ◽  
...  

Abstract BackgroundThe aim of this study was to compare cyclic fatigue resistance (CFR) and separation patterns during rotating movement of five heat-treated nickel titanium files in both single and double-curved canals. MethodsCFR was compared between five groups of 24 files each: HyFlex® EDM, HyFlex™ CM, Vortex Blue®, Protaper Next®, and One Curve, by determining the time needed to fracture (TTF) and the number of cycles to failure (NCF) in a cyclic fatigue testing device with a single 5-mm radius of curvature (ROC) and 60° angle, and a double curvature; coronal curvature (5 mm ROC and 60° angle) and apical curvature (2 mm ROC and 70° angle). The separation pattern was evaluated, and file fragment separated length were measured. One-way ANOVA and Tukey’s post-hoc were used to compare statistical differences between the groups. Scanning Electron Microscope (SEM) was used to investigate the fracture sites. Results HyFlex™ CM files displayed significantly higher CFR, followed by HyFlex® EDM and Vortex Blue® in single curvature canals, and Protaper Next® (PTN) in the double curvature canals, as observed by TFF and NCF. PTN group had the highest tendency for files to extrude apically after separation in both curvatures. ConclusionHyFlex™ CM instruments have superior resistance to cyclic flexural fatigue within single canals with single and double curvatures, followed by HyFlex® EDM and Vortex Blue® instruments. Protaper Next® files followed by One Curve had the highest tendency to extrude apically after separationClinical relevanceHyFlex™ CM instruments showed the highest safety in preparing canals with single or double curvatures, considering CFR.


2020 ◽  
Author(s):  
Amr M. Elnaghy ◽  
Shaymaa E Elsaka ◽  
Ayman Mandorah

Abstract Background: The purpose of this study was to compare the cyclic fatigue resistance of newly developed TruNatomy instruments (TRN) in single and double (S-shaped) curvature canals with HyFlex CM (HCM), Vortex Blue (VB) and RaCe (RC) instruments. Methods: Size 20/.04 taper and size 25/0.04 of HCM, VB and RC were used. For TRN instruments, size 20/.04 taper (small) and size 26/.04 taper (prime) were used. The instruments were tested in artificial canals with double curvature (coronal curve; 60° curvature, 5 mm radius and apical curve; 70° curvature and 2 mm radius) and single curvature (60° curvature, 5 mm radius). The number of cycles to failure (NCF) was recorded. Data were statistically analyzed by Kruskal-Wallis and Dunn’s multiple comparison tests. Weibull analysis was performed on NCF data. Statistical significant was set at p < 0.05. Results: TRN and HCM revealed higher NCF compared with the other instruments for both tested sizes in single and double curvature canals ( p < 0.05). TRN and HCM showed no statistically significant difference in the NCF ( p > 0.05). The probability of survival was higher for HCM and TRN instruments than VB and RC instruments. Conclusions: HCM and TRN instruments were more resistant to cyclic fatigue than VB and RC instruments in single and double curvature canals. HCM and TRN instruments were anticipated to survive with higher number of cycles than the other tested instruments. RC instrument had the lowest fatigue resistance than the other instruments.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Reham Sharroufna ◽  
Mohammed Mashyakhy

Objective. The purpose of this study was to evaluate the effect of repeated autoclave sterilization on the cyclic fatigue resistance of heat-treated NiTi rotary endodontic instruments. Materials and Methods. Three NiTi rotary endodontic instruments (EdgeFile X7, EFX7 0.30/0.4; Vortex Blue, VB 0.30/0.4; and TRUShape, TS 0.30/0.6) were selected. Each group ( n = 24 each) was divided into 2 subgroups ( n = 12 each): sterilized instruments and nonsterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve instruments from each different subgroups were tested for cyclic fatigue resistance, and the number of cycles to failure (NCF) was calculated. Means and standard deviations were calculated for each group, and data were statistically analyzed using the SPSS program ( P < 0.05 ). Results. Sterilized and nonsterilized EFX7 files showed the highest NCF compared with other file subgroups. Comparing the results between sterilized and nonsterilized instruments for each type of files, there was a statistically significant difference ( P < 0.05 ) only between sterilized and nonsterilized EFX7 files (1198 versus 755 NCF). The other instruments did not show significant differences ( P > 0.05 ) in the mean NCF as a result of sterilization cycles (VB, 606 versus 568 NCF; TS, 487 versus 442 NCF). Conclusion. Repeated cycles of autoclave sterilization increased the NCF of the new heat-treated files, with EFX7 showing statistically significant superior results compared with other files tested.


2021 ◽  
Vol 11 (2) ◽  
pp. 863
Author(s):  
Vicente Faus-Llácer ◽  
Nirmine Hamoud Kharrat ◽  
Celia Ruiz-Sánchez ◽  
Ignacio Faus-Matoses ◽  
Álvaro Zubizarreta-Macho ◽  
...  

The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total of 50 unused conventional NiTi wire alloy endodontic rotary instruments were used in this study. All NiTi endodontic rotary files were submitted to a custom-made dynamic cyclic fatigue device until fracture occurred. The time to failure, the number of cycles to failure, the number of pecking movements, and the length of the fractured file tip were analyzed using the analysis of variance (ANOVA) test. In addition, the Weibull characteristic strength and Weibull modulus were also calculated. The paired t-test revealed statistically significant differences between the time to failure, number of cycles to failure, and number of cycles of in-and-out movement of both the apical diameter (p ˂ 0.001) and the taper (p ˂ 0.001) of NiTi endodontic rotary files; however, the results did not show statistically significant differences between the mean length of the fractured files regarding the apical diameter (p = 0.344) and taper study groups (p = 0.344). Increased apical diameter and taper of NiTi endodontic rotary files decreased their dynamic resistance to cyclic fatigue.


2019 ◽  
Vol 18 ◽  
pp. e191208
Author(s):  
Luís César Brisighello ◽  
George Táccio de Miranda Candeiro ◽  
Luiza Riomar Paz ◽  
Hermano Camelo Paiva ◽  
Giulio Gavini

Aim: The aim of present study was to evaluate if the cross-section and the number of use have influence in cyclic fatigue resistance of rotary files. Methods: K3 Endo (group K) and EndoSequence (group E) files, 25/.04, 25 mm, were subdivided into 3 subgroups (n=12) according to the number of uses, 1, 3 and 5 uses, totalizing 72 files. The files were submitted to dynamic assays device moved by an electric engine, using 300 rpm of speed that permitted the reproduction of pecking motion. The files run within a temperate steel ring’s groove, simulating an instrumentation of a curved root canal with 40-degrees and 5-mm of curvature radius. The fracture of file was detected by sensor of device and the time and the number of cycles was acquired. The data were analyzed statistically by two-way ANOVA (p<0.05). Results: There were no statistical significant differences in regard to the number of uses (p>0.05). K3 Endo files showed greater resistance to cyclic fatigue than EndoSequence instruments (p<0.01). Conclusion: It may be concluded that the cross-section of instruments presented significant influence in cyclic fatigue resistance and the number of uses up to 5 times had no influence in cyclic fatigue resistance in both NiTi rotation systems evaluated.


Author(s):  
Anil K Tomer ◽  
Vanita Verma ◽  
Nitin Bhateja ◽  
Pudu Tirupathi ◽  
Sushma Kumari

Aim:  To compare and evaluate the cyclic fatigue resistance of three NiTi rotary file system Materials and Methods: Three NiTi rotary system (Hyflex EDM, Protaper Gold and One curve) were used in study . All files were tested in simulated constructed apparatus with angle of curvature 60o and radius of curvature 5mm.The rotary files were used in endomotor X smart (Densply) .All the instruments were utilized until fracture occurred, and then the number of cycles to failure (NCF) was calculated. The data were analyzed statistically using Annova test. The statistical significance level was set at P < 0.05. Result: HEDM instruments had the highest cyclic fatigue resistance among all the other instruments (P < 0.05). The one curve instruments had a significantly higher fatigue resistance than the Protaper gold instruments (P < 0.05). Conclusion: Within the limitations of this in vitro study, it was found that the cyclic fatigue resistance was higher for the HEDM instruments than for the, Protaper gold and one curve instruments. Keywords: Cyclic fatigue resistance, heat‑treated NiTi instruments, HyFlex EDM, OneCurve