DOSAGE DE L'HORMONE LUTEINISANTE DANS LE PLASMA HUMAIN. RESULTATS CHEZ LES SUJETS NORMAUX DES DEUX SEXES

1965 ◽  
Vol 49 (2) ◽  
pp. 293-298 ◽  
Author(s):  
Jean Louchart ◽  
Jacqueline Truffert ◽  
Jacques Decourt

ABSTRACT An assay method for luteinizing hormone in human plasma is described. The results in healthy men and women are reported: in ten men, a significant level is constantly found, varying from 5 to 14 μg/2.5 ml of plasma. In three women with normal menses, a very low level is found during the preovulatory period, rising significantly at mid-cycle to return afterwards to lower levels, these remaining higher than preovulatory ones.

2011 ◽  
Vol 107 (10) ◽  
pp. 1482-1488 ◽  
Author(s):  
Myriam Richelle ◽  
Pierre Lambelet ◽  
Andreas Rytz ◽  
Isabelle Tavazzi ◽  
Anne-France Mermoud ◽  
...  

Dietary lycopene consists mostly of the (all-E) isomer. Upon absorption, (all-E) lycopene undergoes isomerisation into various (Z)-isomers. Because these isomers offer potentially better health benefits than the (all-E) isomer, the aim of the present study was to investigate if the profile of lycopene isomers in intestinal lipoproteins is affected by the profile of lycopene isomers in the meal and by the tomato preparation. Six postprandial, crossover tests were performed in healthy men. Three meals provided about 70 % of the lycopene as (Z)-isomers, either mainly as 5-(Z) or 13-(Z), or as a mixture of 9-(Z) and 13-(Z) lycopene, while three tomato preparations provided lycopene mainly as the (all-E) isomer. Consumption of the 5-(Z) lycopene-rich meal led to a high (60 %) proportion of this isomer in TAG-rich lipoproteins (TRL), indicating a good absorption and/or a low intestinal conversion of this isomer. By contrast, consumption of meals rich in 9-(Z) and 13-(Z) lycopene isomers resulted in a low level of these isomers but high amounts of the 5-(Z) and (all-E) isomers in TRL. This indicates that the 9-(Z) and 13-(Z) isomers were less absorbed or were converted into 5-(Z) and (all-E) isomers. Dietary (Z)-lycopene isomers were, therefore, differently isomerised and released in TRL during their intestinal absorption in men. Consuming the three meals rich in (all-E) lycopene resulted in similar proportions of lycopene isomers in TRL: 60 % (all-E), 20 % 5-(Z), 9 % 13-(Z), 2 % 9-(Z) and 9 % unidentified (Z)-isomers. These results show that the tomato preparation has no impact on the lycopene isomerisation occurring during absorption in humans.


2020 ◽  
Vol 16 (4) ◽  
pp. 428-435
Author(s):  
Ahmed F.A. Youssef ◽  
Yousry M. Issa ◽  
Kareem M. Nabil

Background: Simeprevir is one of the recently discovered drugs for treating hepatitis C which is one of the major diseases across the globe. Objective: The present study involves the development of a new and unique High-Performance Liquid Chromatography (HPLC) method using fluorescence detection for the determination of simeprevir (SIM) in human plasma. Methods: Two methods of extractions were tested, protein precipitation using acetonitrile and liquidliquid extraction. A 25 mM dipotassium hydrogen orthophosphate (pH 7.0)/ACN (50/50; v/v), was used as mobile phase and C18 reversed phase column as the stationary phase. The chromatographic conditions were optimized and the concentration of simeprevir was determined by using the fluorescence detector. Cyclobenzaprine was used as an internal standard. Results: Recovery of the assay method based on protein precipitation was up to 100%. Intra-day and inter-day accuracies range from 92.30 to 107.80%, with Relative Standard Deviation (RSD) range 1.65-8.02%. The present method was successfully applied to a pharmacokinetic study where SIM was administered as a single dose of 150 mg SIM/capsule (Olysio®) to healthy individuals. Conclusion: This method exhibits high sensitivity with a low limit of quantification 10 ng mL-1, good selectivity using fluorescence detection, wide linear application range 10-3000 ng mL-1, good recovery and highly precise and validation results. The developed method can be applied in routine analysis for real samples.


2016 ◽  
Vol 5 (03) ◽  
pp. 4862 ◽  
Author(s):  
Mathew George* ◽  
Lincy Joseph ◽  
Arpit Kumar Jain ◽  
Anju V.

A simple, sensitive, rapid and economic high performance thin layer chromatographic method and a mass spectroscopic assay method has been developed for the quantification of telmisartan and hydrochlorthiazide combination in human plasma. The internal standards and analytes were extracted from human plasma by solid-phase extraction with HLB Oasis1cc (30mg) catridges. The scanning and optimization for the samples are done using methanol: water (50:50). The samples were chromatographed using reverse phase chromatography with C-18 column of different manufacturers like Ascentis C18 (150×4. 6, 5µ) using the buffer system Acetonitrile: Buffer (80:20%v/v) which consist of 2±0. 1Mm ammonium format at a flow rate of 0. 7ml/min at a column oven temperature 35±10c. The internal standard used was hydrochlorthiazide13c1, d2 and telmisartand3. The extraction techniques include conditioning, loading, washing and elution, drying followed by reconstitution of the dried samples. The volume injected was 10µl with the retention time of 3-4 min for telmisartan, 1-2 min for hydrochlorthiazide and for the internal standards the retention time was 3-4 min for telmisartand3 and 1-2 min for hydrochlorthiazide c13d2. The rinsing solution was Acetonitrile: HPLC grade water in the ratio (50:50). The above developed method was validated using various parameters like selectivity and sensitivity, accuracy and precision, matrix effects, % recovery and various stability studies. The method was proved to be sensitive, accurate, precise and reproducible. The preparation showed high recovery for the quantitative determination of telmisartan and hydrochlorthiazide in human plasma.


Cancers ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 1329
Author(s):  
Li Juel Mortensen ◽  
Mette Lorenzen ◽  
Anne Jørgensen ◽  
Jakob Albrethsen ◽  
Niels Jørgensen ◽  
...  

Luteinizing hormone (LH) and human chorionic gonadotropin (hCG) are agonists for the luteinizing hormone receptor (LHCGR) which regulates male reproductive function. LHCGR may be released into body fluids. We wish to determine whether soluble LHCGR is a marker for gonadal function. Cross-sectional, longitudinal, and intervention studies on 195 healthy boys and men and 396 men with infertility, anorchia, or Klinefelter Syndrome (KS) were used to correlate LHCGR measured in serum, seminal fluid, urine, and hepatic/renal artery and vein with gonadal function. LHCGR was determined in fluids from in vitro and in vivo models of human testicular tissue and cell lines, xenograft mouse models, and human fetal kidney and adrenal glands. Western blot showed LHCGR fragments in serum and gonadal tissue of similar size using three different antibodies. The LHCGR-ELISA had no species cross-reactivity or unspecific reaction in mouse serum even after human xenografting. Instead, sLHCGR was released into the media after the culture of a human fetal kidney and adrenal glands. Serum sLHCGR decreased markedly during puberty in healthy boys (p = 0.0001). In healthy men, serum sLHCGR was inversely associated with the Inhibin B/FSH ratio (β −0.004, p = 0.027). In infertile men, seminal fluid sLHCGR was inversely associated with serum FSH (β 0.006, p = 0.009), sperm concentration (β −3.5, p = 0.003) and total sperm count (β −3.2, p = 0.007). The injection of hCG lowered sLHCGR in serum and urine of healthy men (p < 0.01). In conclusion, sLHCGR is released into body-fluids and linked with pubertal development and gonadal function. Circulating sLHCGR in anorchid men suggests that sLHCGR in serum may originate from and possibly exert actions in non-gonadal tissues. (ClinicalTrials: NTC01411527, NCT01304927, NCT03418896).


2015 ◽  
Vol 56 (4) ◽  
pp. 580-585 ◽  
Author(s):  
A. Biegon ◽  
D. L. Alexoff ◽  
S. W. Kim ◽  
J. Logan ◽  
D. Pareto ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document