scholarly journals Influence of Octacalcium Phosphate addition on physical-mechanical properties of Glass Ionomer Cement

2018 ◽  
Vol 32 (3) ◽  
pp. 127 ◽  
Author(s):  
Gabriela De Souza Balbinot ◽  
Isadora Martini Garcia ◽  
Susana Maria Werner Samuel ◽  
Fabricio Mezzomo Collares ◽  
Vicente Castelo Branco Leitune

OBJECTIVE: The aim of this study was to evaluate the influence of octacalcium phosphate (OCP) addition to conventional glass ionomer cement (GIC).METHODOLOGY: A commercial glass ionomer cement (Vidrion R – S.S. White Artigos Dentários Ltda – Rio de Janeiro, Brazil) was used in this study. OCP was added to powder in 1.5 and 3 wt%. GIC without OCP addition was used as control. Specimens were produced to evaluate radiopacity, setting time and diametral tensile strength of cements. Radiopacity was assessed by phosphor plate system with alluminium step-wedge for comparison. For setting time determination, Gilmore needle (100 g) was used to determine final setting reaction. Diametral tensile strength was measured in a universal testing machine. Data were analyzed by one-way ANOVA at a significance level of 95%.RESULTS: Results showed no statistically significant difference in tested properties with octacalcium phosphate addition in any concentration.CONCLUSION: OCP addition to GIC did not influence materials properties.

2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


2003 ◽  
Vol 14 (3) ◽  
pp. 193-196 ◽  
Author(s):  
Simonides Consani ◽  
Julie Guzela dos Santos ◽  
Lourenço Correr Sobrinho ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Manoel Damião Sousa-Neto

The relationship between metallic cast crowns and tensile strength according to cement types submitted to thermocycling was studied. Seventy-two metallic crowns were cast with Verabond II Ni-Cr alloy and cemented in standardized preparations with 10º tapering. Three types of finishing line (45-degree chamfered, 20-degree bevel shoulder and right shoulder) were made with diamond burs on bovine teeth. Twenty-four metallic crowns in each group were randomly subdivided into three subgroups of 8 samples each according to the cement used: SS White zinc phosphate cement, Vitremer resin-modified glass ionomer cement, and Rely X resin cement and were submitted to thermocycling. Retention was evaluated according to tensile load required to displace the metallic cast crowns from tooth preparations with an Instron testing machine. ANOVA and Tukey's test showed a statistically significant difference among luting materials, with greater results for Rely X resin cement (24.9 kgf) followed by SS White zinc phosphate cement (13.3 kgf) and Vitremer resin-modified glass ionomer cement (10.1 kgf). The finishing line types did not influence the tensile resistance of the crowns fixed with the three cements. Increased tensile resistance of metallic crowns fixed on bovine teeth was obtained with resin cement, independent of the finishing line types.


2011 ◽  
Vol 264-265 ◽  
pp. 508-512
Author(s):  
Ammar A. Mustafa ◽  
Khalid A. S. Al-Khateeb ◽  
Ahmad Faris Ismail

Experimental glass ionomer cement was prepared for the purpose of this study. Twenty disk specimens (16mm diameter x 10mm height) of test-GIC were prepared for the diametral tensile strength (DTS) test and twenty cylindrical specimens (6 mm diameter x 16mm height) were prepared for the compressive strength (CS) test. Specimens were stored in an artificial saliva at 37º C and (50±10%) of relative humidity in an incubator until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours, 7 days and 28 days. The specimens were tested in a Universal Testing Machine (Instron 1122, Instron corp., High Wycombe, U.K.) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The results have revealed that incorporation of lithium fluoride in the formula of the test GIC might impart an increase in the mechanical properties of the GICs


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


2018 ◽  
Vol 14 (1) ◽  
pp. 24
Author(s):  
Dr. Sazan Sherdil Saleem

The present study was aimed to evaluate and compare the compressive strength ofconventional glass ionomer cement with resin modified glass ionomer, compomer andmicrohybrid composite. A total of 40 specimens of esthetic restorative materials werefabricated using customized cylindrical teflon mould measuring 6mm height and 4mmdiameter and were grouped with ten specimens in each group, Group I: Conventionalglass ionomer cement (Fuji II). Group II: Resin modified glass ionomer (Fuji II LC).Group III: Compomer (Dyract AP) and Group IV: Microhybrid composite resin(Tetric Ceram).They were covered with Mylar strip and were cured using LED lightcuring unit. Compressive strength was evaluated using Universal testing machine. Theresult showed that there were a significant difference among the groups in whichTetric Ceram showed highest compressive strength and Fuji II showed the leastcompressive strength


2020 ◽  
Vol 10 (11) ◽  
pp. 1960-1964
Author(s):  
Mansour K. A. Assery ◽  
Abdulrahman Alshubat ◽  
AlWaleed Abushanan ◽  
Nawaf Labban ◽  
Mohamed Hashem

The study evaluated the addition of silver (Ag) and titanium dioxide (TiO2) nanoparticles to conventional glass ionomer cement (GIC), considering compressive strength (CS), diametral tensile strength (DTS), flexural strength (FS), and hardness. Ag and TiO2 nanoparticles were blended into the powder of a commercially available GIC restorative material at 5% (w/w). Unblended powder was used as a control. One hundred twenty samples were prepared from two study groups and one control group (n = 10). CS, DTS, and FS were evaluated using a universal testing machine, while hardness was measured by Vickers microhardness testing. The data obtained were analyzed using One-way analysis of variance and the Tukey?s test (p < 0.05). GIC containing Ag and TiO2 nanoparticles significantly improved the CS, DTS, and hardness compared to the control group (p < 0.05). However, the FS was not much affected by the addition of either of the nanoparticles (p >0.05). TiO2 blended GIC demonstrated significantly higher CS (154.20+2.38) and DTS (13.2±0.5 MPa) compared to control 117.2±1.2 MPa and 7.2 ±0.8 MPa, respectively. While Blend of GIC+Ag nanoparticles showed the highest FS (29.0±0.7 MPa). Additionally, the blend of GIC+TiO2 exhibited the highest hardness (90.4±1.1 VHN). Ag and TiO2 blended GICs might guarantee their use in occlusal or higher stress-bearing areas.


2012 ◽  
Vol 23 (4) ◽  
pp. 379-386 ◽  
Author(s):  
Adriano Augusto Melo de Mendonça ◽  
Camila Fávero de Oliveira ◽  
Josimeri Hebling ◽  
Carlos Alberto de Souza Costa

This study evaluated the transdentinal cytotoxicity (TC) and the bond strength (BS) of a resin-modified glass-ionomer cement (RMGIC) applied to dentin covered with smear layer (SL) of different thicknesses. Forty dentin discs had thick (TSL) or thin (THSL) smear layer created on their occlusal side. In artificial pulp chambers, MDPC-23 cells were seeded on the pulpal side of the dentin discs and divided into five groups: G1TC: no treatment (control); G2TC: TSL + RMGIC; G3TC: THSL + RMGIC; G4TC: TSL removal + RMGIC; G5TC: THSL removal + RMGIC. After 24 h, cell metabolism and morphology were evaluated by the methyltetrazolium (MTT) assay and by scanning electron microscopy (SEM), respectively. For BS, the following groups were determined: G1BS: TSL removal + RMGIC; G2BS: THSL removal + RMGIC; G3BS: TSL + RMGIC; G4BS: THSL + RMGIC. Shear bond strength was tested to failure in a mechanical testing machine MTS (0.5 mm/min). Statistically significant difference was observed only between the control and experimental groups (Kruskal-Wallis, p<0.05). The metabolic activity of the viable MDPC-23 cells in G2TC, G3TC, G4TC and G5TC decreased by 54.85%, 60.79%, 64.12% and 62.51%, respectively. Mean shear bond strength values for G1BS, G2BS, G3BS and G4BS were 7.5, 7.4, 6.4 and 6.7 MPa, respectively, without significant difference among them (ANOVA, p>0.05). RMGIC presented moderate transdentinal cytotoxic effects. Maintenance or removal of smear layer did not affect the bond strength of RMGIC to dentin substrate.


2003 ◽  
Vol 9 (1-2) ◽  
pp. 201-207 ◽  
Author(s):  
F. Saleh ◽  
N. Taymour

Shear and tensile bond strengths of 40 human and 40 bovine teeth were compared. Teeth were randomly assigned to group I, which received light-cured composite resin, or group II, which received light-cured resin-reinforced glass ionomer cement. The groups were subdivided for shear and tensile bond strength tests, which were conducted on a universal testing machine installed to a computer transducer. Statistical analysis revealed a highly significant difference between shear and tensile bond strengths of human and bovine enamel; however, regression prediction equations support the use of bovine teeth as a reliable substitute to human counterparts in bonding studies of orthodontic adhesion


Sign in / Sign up

Export Citation Format

Share Document