scholarly journals Application of protection device in autotransformer high-voltage winding neutral for increasing the efficiency of single-phase short-circuit current limiting

2011 ◽  
Vol 0 (1) ◽  
pp. 60-63
Author(s):  
N. V. Vyshnevsky ◽  
A.N. Andriyenko
Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4729
Author(s):  
Rafał Tarko ◽  
Jakub Gajdzica ◽  
Wiesław Nowak ◽  
Waldemar Szpyra

The article deals with the problems of single-phase short-circuit current distribution in overhead power lines. Short-circuit disturbances cause many negative phenomena in power networks. Since experimental studies of short-circuits in real networks are practically impossible to perform, these effects can be evaluated only theoretically, based on short-circuit current calculations with the use of appropriate mathematical models. Although short-circuit modeling is considered to be one of the simplest power system calculations, the exact mathematical description of the phenomena occurring at short-circuits is complex. Simplified normative methods are often used for short-circuit current calculations; however, this does not give ground for a thorough analysis of short-circuit current distribution in power lines. The distributions are analyzed using power line models with different degrees of complexity in line with the assumptions made for a given model. The paper presents the problem of current distribution analysis in high-voltage overhead lines for single-phase faults to the tower structures. Simulation studies were conducted on the models developed for the calculation of short-circuit currents in the high-voltage power line earthing. The objective of the analysis was to assess the validity of simplification assumptions followed by practical recommendations on the applicability of the models.


2017 ◽  
pp. 34-41
Author(s):  
Andrei V. MAIOROV ◽  
◽  
Kirill A. OSINTSEV ◽  
Andrei V. SHUNTOV ◽  
◽  
...  

2013 ◽  
Vol 722 ◽  
pp. 223-227
Author(s):  
Tie Ying Zhao ◽  
Yan Wen Wang

Current limiting reactor can increase systems short circuit impedance so as to limit short circuit current. Current limiting reactor is directly involved in whole short circuit process when a short circuit fault occurs in a power system, which makes short-circuit current change more complex. Short circuit current level is affected by current limiting reactors parameters; a current limiting reactor with proper impedance value can maintain short-circuit current at an acceptable range. A short circuit transient process of a distributing network with current limiting reactor was analyzed, and the formula of current changing in short circuit transient process was deduced; according to the current changing formula, an engineering calculation formula of current limiting reactors impedance was derived. The case calculation shows that current limiting reactor meeting the need of the engineering calculation formula can reach the system current limiting requirement.


2018 ◽  
Vol 18 (4) ◽  
pp. 162-167 ◽  
Author(s):  
Miroslav Gutten ◽  
Daniel Korenciak ◽  
Matej Kucera ◽  
Richard Janura ◽  
Adam Glowacz ◽  
...  

Abstract The authors describe experimental and theoretical analyses of faults of power transformer winding. Faults were caused by mechanical effect of short-circuit currents. Measurements of transformer were carried out in high-voltage laboratory. Frequency and time diagnostic methods (method SFRA - Sweep Frequency Response Analysis, impact test) were used for the analyses. Coils of transformer windings were diagnosed by means of the SFRA method and the time impact test. The analyzed methods had a significant sensitivity to a relatively small deformation of coil. In the analysis a new technique for analyzing the effects of short-circuit currents is introduced. This technique is developed for high-voltage transformers (different types of power). The proposed analyses show that it is necessary to analyze the value of short-circuit current. Short-circuit current represents a danger for the operation of the power transformer. The proposed approach can be used for other types of transformers. Moreover, the presented techniques have a potential application for fault diagnosis of electrical equipment such as: transformers and electrical machines.


2010 ◽  
Vol 47 (1) ◽  
pp. 86-93
Author(s):  
Saurabh Kumar Mukerji ◽  
Moleykutty George

An augmented short-circuit test is described for the determination of equivalent-circuit parameters of single-phase transformers with large series-branch impedances. This test may be conducted at rated currents with the transformer connected to a reduced voltage supply. Thus harmonics in current and voltage waves are negligible. This test is therefore free from harmonics-associated errors. Based on test results, phasor equations are found which give formulae for the equivalent-circuit parameters with series-branch impedance split into low- and high-voltage components.


2013 ◽  
Vol 389 ◽  
pp. 1089-1095
Author(s):  
Jun Zhen Peng ◽  
Kun Nan Cao ◽  
Da Da Wang ◽  
Meng Song ◽  
Nan Nan Hu ◽  
...  

As one of the most applicable to high-voltage network superconducting fault current limiterSCFCL(saturated core superconducting fault current limiter) ,which use of core saturation properties can be achieved the current-limiting function without delay ,will be the most widely applied in the future,By analyzing the working principle of SCFCL,this paper use of PSCAD and finite element analysis software Ansoft to build the 500kV\/3150A grade SCFCL model and accurate calculation coil self-inductance and mutual inductance, the harmonic of each size and analyzed its Impedance characteristic on the different external parameters,The results show that SCFCL has a excellent performance for high voltage power network short-circuit current limitation, and provides important reference for design.