scholarly journals DESIGN OF AIR CONDITIONING AND VENTILATION SYSTEM FOR A MULTI-STOREY OFFICE BUILDING

2013 ◽  
Vol 02 (08) ◽  
pp. 360-364
Author(s):  
G. Prasanthi .
2019 ◽  
Vol 111 ◽  
pp. 01085
Author(s):  
Hiroshi Muramatsu ◽  
Tatsuo Nobe

In this study, an office building in Japan that incorporates energy-saving features and environmental technologies was investigated. This office building features a green façade, natural ventilation, a concrete slab with no suspended ceilings, and thermo-active building systems. Two airconditioning systems were installed in this building—a ceiling radiation air-conditioning system and a whole floor-blow off air conditioning system. In addition, a natural ventilation system was installed. We surveyed the heat flux of the ceiling surface and indoor thermal environment of this building from 2015 through 2016. The ceiling using the heat storage amount of concrete maintains a constant temperature in the workplace during as well as after office hours. We also performed detailed measurements of the heat flux of the ceiling surface and indoor thermal environment in the summer of 2017. The results showed that the ceiling radiation air-conditioning system provided a stable thermal environment. Furthermore, we report that making use of the thermal behavior of the skeleton improved the operation of the ceiling radiation airconditioning system.


2018 ◽  
Vol 3 (8) ◽  
pp. 35
Author(s):  
Chinedum Vincent Okafor ◽  
Kevin Chuks Okolie ◽  
Peter Ogunoh ◽  
Udeagwu Hyginus Oguike

This study carried out a comparative study to evaluate the air-conditioning performance of an office space under two typical ventilation modes (displacement and mixing ventilation system). A wall supply diffuser is located at the ceiling height for the mixing ventilation case, whereas, the supply diffuser is at the floor level for the displacement ventilation case. In both cases, the exhaust grill is located at the ceiling. From the result of the simulation, the researchers observed that the displacement ventilation system could have a higher risk of discomfort relating to vertical temperature gradient than when compared to the mixing ventilation case. More so, the simulation result indicates that the temperature distribution in an office building is a function of the type of ventilation system adopted and marginally affected by the diffuser arrangement.


2019 ◽  
Vol 111 ◽  
pp. 02044
Author(s):  
Akemi Iwaki ◽  
Takashi Akimoto ◽  
Naho Misumi ◽  
Takuya Furuhashi

This study focused on the thermal comfort of air circulation-type whole-house air-conditioning ventilation systems. We studied the influence of 24-h continuous whole-house air-conditioning on the living environment in which the occupant is sleeping. A survey was conducted in the summer of 2016 and winter of 2017 to ascertain the influence on the sleeping environment, skin moisture content, and blood pressure. We then compared the results with those of the sleeping environment of residents in air-conditioned housing surveyed the previous year. The sleeping environment when using a personal humidifier around the occupant’s head was examined during winter when the humidity is low. The results indicated that sleep latency was significantly shortened in the 24-h continuous whole-house air-conditioning ventilation system in both summer and winter because the temperature control of the bedroom before going to bed affects the sleep latency. Subjectively, no participants felt dryer than the values measured in the bedroom environment. The results implied that the comfort of the entire building was improved with continuous air-conditioned housing.


Author(s):  
Eny Nor Syahira Mohamad Hashim ◽  
◽  
Norhafizah Salleh ◽  
Noor Azlina Abdul Hamid ◽  
◽  
...  

This paper proposes a cooling house system that can promote thermal comfort in buildings without air-conditioning. The cooling panel wall forms a part of an Integrated Building System (IBS), and is essentially made of tubes filled with either water or glycerin as the coolant. Target strength for the panel wall was designed based on the Malaysian Standard (MS) while the building ventilation system followed the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) standard. The results are reported based on indoor and outdoor temperature difference together with relative humidity to identify the best performing house model and also coolant. The outcome of this research is expected to add value to design concepts with a better promotion of air flow and circulation in the building, without over-usage of natural resources and higher building cost to achieve the same objective.


2012 ◽  
Vol 516-517 ◽  
pp. 1139-1143
Author(s):  
Ke Chun Sun ◽  
Wei Jun Zhang

Chongqing weather conditions as the representative, energy simulation software DesT-c Chongqing office building energy simulation analysis, simulated natural building under different ventilation conditions at room temperature, the energy consumption of building cooling load and air-conditioning system changes, with an emphasis on energy-saving effect of the night ventilation; The study showed that in Chongqing reasonable use of ventilation reduce building natural room temperature to a certain extent; Sensitive indicators of building air conditioning energy consumption than the heating energy consumption of ventilation was significantly; Night ventilation when the number of ventilators is less than 5 times / h, the energy saving effect is very significant.


2021 ◽  
pp. 1420326X2110395 ◽  
Author(s):  
Carlo Cravero ◽  
Davide Marsano

The COVID-19 infection has emerged as a disruptive pandemic at worldwide level. The study of the mechanism of contagion is one of the greatest challenges before a mass vaccination campaign that would protect populations. The study can support the development of knowledge and tools to develop possible strategies for containing its spread in future events. The saliva droplet aerosol expelled during breathing or coughing is the main cause for the propagation of the SARS-Cov-2. In this work, a URANS CFD approach was used to simulate the dispersion from the mouth of these particles in closed environments. The air conditioning system was considered. The conditions were varied to determine their impact on the diffusion of the aerosol. Lagrangian and Eulerian numerical approaches were used to model the coughing and the breathing events. These were validated with the puff theory, numerical and experimental results. A realistic case of a meeting room with two persons was simulated. Different characteristics of the expulsed aerosols and different ventilation system configurations were considered to demonstrate how these simulations can support management strategies for indoor occupation. Finally, the effect of the protective mask was introduced to quantify its beneficial effects to support safe indoor occupation.