scholarly journals Bonding Effectiveness of Universal Adhesive to Intracoronal Bleached Dentin Treated with Sodium Ascorbate

2016 ◽  
Vol 27 (3) ◽  
pp. 303-308 ◽  
Author(s):  
Thaís Fantinato Trindade ◽  
Luana Kelle Batista Moura ◽  
Walter Raucci Neto ◽  
Danielle Cristine Furtado Messias ◽  
Vivian Colucci

Abstract This study evaluated the effect of restorative protocol with sodium ascorbate on the shear bond strength (SBS) of a universal adhesive to intracoronal bleached dentin. One hundred-and-twenty bovine dentin fragments were randomly divided into 12 groups (n=10), according to the bleaching procedure (unbleached and bleached) and restorative protocol (no treatment, 10% sodium ascorbate -10SA, 35% sodium ascorbate -35SA and two-step etch-and-rinse -ER or one-step self-etch -SE Scotchbond universal adhesive approaches). Four whitening sessions were performed using 35% hydrogen peroxide. The samples from control groups were kept in relative humidity at 37 °C. Immediately after bleaching procedures, the assigned antioxidant solution was applied on dentin and restorative procedures were performed following either the ER or the SE approach. After 24 h, the specimens were subjected to SBS test. Data (MPa) were analyzed by ANOVA and Tukey's test (?=0.05). Lower SBS values were found for bleached specimens (8.54 MPa) compared with those unbleached (12.13 MPa) (p<0.05). The bond strength of the sodium ascorbate-treated groups was higher than those untreated, regardless of the strategy employed (p<0.05). Groups restored without sodium ascorbate showed lower bond strength values for both ER (8.32 MPa) and SE (8.28 MPa) adhesive strategies. The group treated with 10SA submitted to ER approach (10.14 MPa) was similar to untreated groups (p>0.05). It may be concluded that bond strength of composite resin to intracoronal dentin was affected by restorative protocol and reduced by bleaching.

Author(s):  
Ganapathi Vasavi Prasanna ◽  
Vemareddy Rajasekhar ◽  
Someshwar Battu ◽  
Korrai Balaraju ◽  
Seera Sudhakar Naidu ◽  
...  

Aims and Objectives: The main aim of this study is to compare and evaluate the shear bond strength of composite resin using a total etch adhesive and self-etch adhesive after treatment with different collagen cross-linking agents. Materials and Methods: Forty freshly extracted human maxillary central incisors were taken. The proximal dentin was exposed, cavities were prepared on mesial and distal of each tooth. The specimens were randomly divided into two groups based on bonding agent applied-Group A and Group B i.e universal bonding agent and all in one bonding agent respectively and are subdivided into four groups based on the surface treatment of dentin. Group I A (n=10) Control-total etch(CTE); Group II A (n=10) Sodium Ascorbate-total etch (STE); Group III A (n=10)- Proanthocyanidin total etch(PTE); Group IV A (n=10)- Chitosan total etch (CHTE); Group I B (n=10) Control-self etch (CSE); Group II B (n=10) Sodium Ascorbate-self etch(SSE); Group III B (n=10)- Proanthocyanidin self-etch (PSE); and Group IV B (n=10) - Chitosan self-etch (CHSE). Shear bond strength of the specimens are tested with universal testing machine, and the data was statistically analysed with one way ANOVA. Results: Significantly higher shear bond strength to dentin was observed in teeth treated with 6.5% Proanthocyanidin Total etch, 10% Sodium Ascorbate Total etch and 1% Chitosan acetate compared to the control group. No significant difference was seen with self-etch treated groups. Conclusion: Dentin surface pretreatment with 6.5% Proanthocyanidin, 10% Sodium Ascorbate and 1% Chitosan acetate results in significant enhancement in bond strength of composite resin to deep dentin.


2021 ◽  
Vol 15 (2) ◽  
pp. 82-86
Author(s):  
Mahmoud Bahari ◽  
Siavash Savadi Oskoee ◽  
Mohammad Esmaeel Ebrahimi Chaharom ◽  
Nasim Molayi

Background. Contamination of dentin surface is one of the common problems in restorative dentistry. The aim was to investigate the effects of different surface contaminators on the dentin shear bond strength (SBS) of universal adhesive system (UAS) applied in etch-and-rinse (ER) and self-etch (SE) strategies. Methods. One hundred forty-four maxillary anterior sound human teeth were divided into six groups based on the types of surface contaminators: no surface contaminator (control) and experimental groups contaminated with blood, saliva, aluminium chloride (ALC), ferric sulphate (FS), and caries disclosing agent (CDA). Then, each group was further subdivided into two, based on the application strategy of UAS (ER and SE). After applying the adhesive according to the manufacturer’s instructions, and bonding cylindrical composite samples, the SBS was measured. The data were analysed using two-way ANOVA, Tukey’s HSD test and t test (P<0.05). Results. The SBS in all contaminated groups, except for CDA, was significantly lower in both ER and SE strategies compared to control group (P<0.05). A comparison between the application strategies revealed that ER and SE were only significantly different in the FS contaminated group (P<0.05). Conclusion. All tested contaminators, except CDA, significantly decreased SBS of UAS in both ER and SE strategies.


2017 ◽  
Vol 20 (1) ◽  
pp. 99
Author(s):  
Alessandra Pereira Andrade ◽  
Angela Mayumi Shimaoka ◽  
Rubens Corte Real de Carvalho

Objective: The objective of this study was to evaluate the combination effect of surface treatments and bonding agents on bond strength of repairs on aged composite resin. Materials and Methods: One hundred twenty microhybrid composite units (Filtek Z250) aged in distilled at 37ºC water for six months were submitted to different surface treatment prior to resin repairs. Ten specimens were randomly divided into 12 groups: non-treated/no bonding agent (negative control), sandblasting /no bonding agent, silane/no bonding agent, non-treated/ etch-and-rinse; non-treated/one-step self-etch; non-treated/ two-step self-etch; sandblasting/etch-and-rinse; sandblasting/one-step self-etch; sandblasting/two-step self-etch; silane coupling agent/etch-and-rinse; silane coupling agent/ one-step self-etch; silane coupling agent/two-step self-etch. Microshear testing was performed to bond strength assessment. Results: Two-way ANOVA and Tukey’s test (α=0.05) demonstrated significant difference between the surface treatments and adhesive systems. Only no treated surface/etch-and-rinse group showed lower bond strength values when compared to other groups. Conclusion: The considered surface treatments were capable to increase the effectiveness of the repair in composite resin when using the adhesive etch-and-rinse.


2017 ◽  
Vol 42 (2) ◽  
pp. E71-E80 ◽  
Author(s):  
RF Zanatta ◽  
M Lungova ◽  
AB Borges ◽  
CRG Torres ◽  
H-G Sydow ◽  
...  

SUMMARY Objectives: The aim of this study was to evaluate microleakage and shear bond strength of composite restorations under different cycling conditions. Methods and Materials: Class V cavities were prepared in the buccal and lingual surfaces of 30 human molars (n=60). A further 60 molars were used to prepare flat enamel and dentin specimens (n=60 each). Cavities and specimens were divided into six groups and pretreated with an adhesive (self-etch/Clearfil SE Bond or etch-and-rinse/Optibond FL). Composite was inserted in the cavities or adhered to the specimens' surfaces, respectively, and submitted to cycling (control: no cycling; thermal cycling: 10,000 cycles, 5°C to 55°C; thermal/erosive cycling: thermal cycling plus storage in hydrochloric acid pH 2.1, 5 minutes, 6×/day, 8 days). Microleakage was quantified by stereomicroscopy in enamel and dentin margins after immersion in silver nitrate. Specimens were submitted to shear bond strength testing. Statistical analysis was done by two-way analysis of variance and Kruskal-Wallis tests (p&lt;0.05). Results: Microleakage in enamel margins was significantly lower in the control group compared with thermal cycling or thermal/erosive cycling. Erosive conditions increased microleakage compared with thermal cycling (significant only for Clearfil SE Bond). No significant differences were observed in dentin margins. Bond strength of enamel specimens was reduced by thermal cycling and thermal/erosive cycling when Clearfil SE Bond was used and only by thermal/erosive cycling when Optibond FL was used. No differences were observed among dentin specimens. Conclusions: Thermal/erosive cycling can adversely affect microleakage and shear bond strength of composite resin bonded to enamel.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2012 ◽  
Vol 06 (03) ◽  
pp. 280-286 ◽  
Author(s):  
A. Ruya Yazici ◽  
Zeren Yildirim ◽  
Atila Ertan ◽  
Gül Ozgunaltay ◽  
Berrin Dayangac ◽  
...  

ABSTRACTObjectives: The aim of this study was to compare the shear bond strength of several self-etch adhesives to their two-step predecessors to ground and unground enamel.Methods: Seventy-five extracted, non-carious human third molar teeth were selected for this study. The buccal surfaces of each tooth were mechanically ground to obtain flat enamel surfaces (ground enamel), while the lingual surfaces were left intact (unground enamel). The teeth were randomly divided into five groups according to the adhesive systems (n=15): one-step self-etch adhesive - Clearfil S3 Bond, its two-step predecessor - Clearfil SE Bond, one-step self-etch adhesive - AdheSE One, and its two-step predecessor - AdheSE, and a two-step etch-and-rinse adhesive - Adper Single Bond 2(control). After application of the adhesives to the buccal and lingual enamel surfaces of each tooth, a cylindrical capsule filled with a hybrid composite resin (TPH) was seated against the surfaces. The specimens were stored in distilled water at 37°C for 24 hours, followed by thermocycling (5°C-55°C/500 cycles). They were subjected to shear bond strength test in a universal testing machine at a crosshead speed of 1.0 mm/minute. The data were compared using a two-way ANOVA, followed by Bonferroni test at P<.05Results: All adhesives exhibited statistically similar bond strengths to ground and unground enamel except for the etch-and-rinse adhesive that showed significantly higher bond strengths than the self-etch adhesives (P<.05). No significant differences in bond strength values were observed between ground and unground enamel for any of the adhesives tested (P=.17).Conclusions:Similar bond strengths to ground and unground enamel were achieved with one-step self-etch adhesives and their predecessors. Enamel preparation did not influence the bonding performance of the adhesives tested. (Eur J Dent 2012;6:280-286)


2021 ◽  
Vol 45 (3) ◽  
pp. 186-192
Author(s):  
Min Jin Kim ◽  
Joonhee Kim ◽  
Ji-Soo Song ◽  
Shin Hye Chung ◽  
Hong-Keun Hyun

Objective: To compare the shear bond strength (SBS) after thermocycling of four universal adhesives applied in self-etch mode on dentin and etch-and-rinse mode on enamel. Study design: Flat 144 buccal or lingual dentin and enamel surfaces from 72 non-carious primary molars were prepared. Samples were segregated into 12 groups (n=12): Adper Single Bond 2 etch-and-rinse (SB_T) and Clearfil SE Bond self-etch (SE_S) applied to enamel and dentin served as controls. Scotch Bond Universal Adhesive (SBU), Clearfil S3 Bond Universal Adhesive (SEU), Tetric N-Bond Universal Adhesive (TEN), and All Bond Universal (BIS) were applied in etch-and-rinse mode to enamel and in self-etch mode to dentin. They were thermocycled for 5000 cycles. SBS testing and the evaluation of fracture mode were performed. Results: SB_T showed statistically higher SBS than other adhesive groups using etch-and-rinse mode on enamel. SE_S and BIS had statistically higher SBS than other adhesive groups using self-etch mode on dentin. Mixed failure was the most common failure mode in each group. Conclusion: The universal adhesives did not show higher SBS than SB_T when using etch-and-rinse on enamel. All universal adhesives showed higher SBS than SB_T and had SBS similar to SE_S, except SBU when using self-etch mode on dentin.


Healthcare ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 128
Author(s):  
Satheesh B. Haralur ◽  
Salem Mohammed Alharthi ◽  
Saeed Aied Abohasel ◽  
Khalid Mohammed alqahtani

Blood–saliva contamination negatively affects the bonding potential of adhesive agents. The study aimed to assess the effect of various cleaning protocols on micro-shear bond strength (μSBS) between blood–saliva-contaminated post-etched dentin and composite resin in total-etch and self-etch adhesives. The cleaning methods tested were water rinsing, 37.5% phosphoric acid (H3PO4) re-etching, 6% sodium hypochlorite (NaoCl), 2% chlorhexidine gluconate (CXG), isopropyl alcohol (IPA), and pumice. Nono-hybrid composite cylinders with a 3-mm diameter and 2-mm height were directly cured over the dentin substrate, stored for 24 h, and subjected to 12,000 thermocycles. The shear force was exerted with a 200-μm knife-edged chisel-shaped head from a universal testing machine. The type of failure was assessed with stereomicroscope magnified images. The obtained data were evaluated by Kruskal–Wallis and Mann–Whitney U post-hoc tests. Water-rinsed contaminated dentin surfaces showed substantially reduced μSBS in the total etch from 25.93 to 20.29 Mpa and the corresponding values for the one-step self-etch adhesive were 10.10 to 8.8. Re-etching with 37.5% H3Po4 resulted in a recovery of bonding potential in both total-etch (24.58 Mpa) and self-etch adhesive (9.23 Mpa). Alternately, NaoCl and pumice cleaning showed promising results for the total-etch (23.51 Mpa) and self-etch (7.79 Mpa).


2015 ◽  
Vol 40 (4) ◽  
pp. 410-417 ◽  
Author(s):  
DE McLean ◽  
EJ Meyers ◽  
VL Guillory ◽  
KS Vandewalle

SUMMARY Purpose Universal bonding agents have been introduced for use as self-etch or etch-and-rinse adhesives depending on the dental substrate and clinician's preference. The purpose of this study was to evaluate the shear bond strength (SBS) of composite to enamel using universal adhesives compared to a self-etch adhesive when applied in self-etch and etch-and-rinse modes over time. Methods and Materials Extracted human third molars were used to create 120 enamel specimens. The specimens were ground flat and randomly divided into three groups: two universal adhesives and one self-etch adhesive. Each group was then subdivided, with half the specimens bonded in self-etch mode and half in etch-and-rinse mode. The adhesives were applied as per manufacturers' instructions, and composite was bonded using a standardized mold and cured incrementally. The groups were further divided into two subgroups with 10 specimens each. One subgroup was stored for 24 hours and the second for six months in 37°C distilled water and tested in shear. Failure mode was also determined for each specimen. Results A three-way analysis of variance (ANOVA) found a significant difference between groups based on bonding agent (p&lt;0.001) and surface treatment (p&lt;0.001) but not on time (p=0.943), with no significant interaction (p&gt;0.05). Clearfil SE in etch-and-rinse and self-etch modes had more mixed fractures than either universal adhesive in either mode. Conclusions Etching enamel significantly increased the SBS of composite to enamel. Clearfil SE had significantly greater bond strength to enamel than either universal adhesive, which were not significantly different from each other.


Sign in / Sign up

Export Citation Format

Share Document