scholarly journals Motor Activity Log-Brazil: reliability and relationships with motor impairments in individuals with chronic stroke

2012 ◽  
Vol 70 (3) ◽  
pp. 196-201 ◽  
Author(s):  
Natalia Duarte Pereira ◽  
Angélica Cristiane Ovando ◽  
Stella Maris Michaelsen ◽  
Sarah Monteiro dos Anjos ◽  
Renata Cristina Magalhães Lima ◽  
...  

The Motor Activity Log (MAL) assesses the spontaneous use of the most affected upper limb with the amount of use (AOU) and quality of movement (QOM) scales during daily activities in real environments in individuals with chronic stroke. Objectives: This study translated the testing manual into Portuguese and assessed the inter-rater and test-retest reliabilities of the MAL, based upon the Brazilian manual version. Methods: The inter-rater reliability was evaluated by comparing the results of two examiners, and the test-retest reliability was tested by comparing the results of two evaluations, repeated one-week apart with 30 individuals with chronic hemiparesis (55.8±15.1 years). Results: The intra-class correlation coefficients (ICCs) for the total scores were adequate for both the inter-rater (0.98 for the AOU and 0.91 for QOM) and test-retest reliabilities (0.99 for both scales). Conclusions: The results suggested that the MAL was reliable to evaluate the spontaneous use of the most affected upper limb after stroke.

2021 ◽  
pp. jrheum.210175
Author(s):  
Ying Ying Leung ◽  
William Tillett ◽  
Pil Hojgaard ◽  
Ana-Maria Orbai ◽  
Richard Holland ◽  
...  

Objective Due to no existing data, we aimed to derive evidence to support test-retest reliability for the Health Assessment Questionnaire-Disability Index (HAQ-DI) and Medical Outcome Survey Short-Form-36 item physical functioning domain (SF-36 PF) in psoriatic arthritis (PsA). Methods We identified datasets that collected relevant data for test-retest reliability for HAQ-DI and SF-36 PF; and evaluated them using OMERACT Filter 2.1 methodology. We calculated intra-class correlation coefficients (ICC) as a measure of test-retest reliability. We then conducted a quality assessment and evaluated the adequacy of test-retest reliability performance. Results Two datasets were identified for HAQ-DI and one for SF-36 PF in PsA. The quality of the datasets was good. The ICCs for HAQ-DI were excellent in both datasets: 0.94 (95% CI: 0.88 to 0.97) and 0.94 (95% CI: 0.89 to 0.97). The ICC of SF-36 PF was good (0.89, 95% CI: 0.76 to 0.95). The performance of test-retest reliability for both instruments was judged to be adequate. Conclusion The new data derived support good and reasonable test-retest reliability for HAQ-DI and SF-36 PF in PsA.


Author(s):  
Khalil Taherzadeh Chenani ◽  
Farzan Madadizadeh

Introduction: Reliability is an integral part of measuring the reproducibility of research information. Intra-cluster correlation coefficient (ICC) is one of the necessary indicators for reliability reporting, which can be misleading in terms of its diversity. The main purpose of this study was to introduce the types of reliability and appropriate ICC indices.  Methods: In this tutorial article, useful information about the types of reliability and indicators needed to report the results, as well as the types of ICC and its applications were explained for dummies. Results: Three general types of reliability include inter-rater reliability, test-retest reliability, and intra-rater reliability was presented. 10 different types of ICC were also introduced and explained. Conclusion: The research results may be misleading if any of the reliability types and calculation criteria types are chosen incorrectly. Therefore, to make the results of the study more accurate and valuable. Medical researchers must seek help from relevant guidelines such as this study before conducting reliability analysis.  


2008 ◽  
Vol 88 (3) ◽  
pp. 333-340 ◽  
Author(s):  
Stephen J Page ◽  
Peter Levine ◽  
Anthony Leonard ◽  
Jerzy P Szaflarski ◽  
Brett M Kissela

Background and Purpose This single-blinded randomized controlled trial compared the efficacy of a reimbursable, outpatient, modified constraint-induced therapy (mCIT) protocol (half-hour therapy sessions occurring 3 days per week in which subjects used the more affected arm combined with less affected arm restriction 5 days per week for 5 hours; both of these regimens were administered during a 10-week period) with that of a time-matched exercise program for the more affected arm or a no-treatment control regimen. Subjects Thirty-five subjects with chronic stroke participated in the study. Methods The Action Research Arm Test (ARAT), Fugl-Meyer Assessment of Motor Recovery After Stroke (FM), and Motor Activity Log (MAL) were administered to the subjects. Results After intervention, significant differences were observed on the ARAT and MAL Amount of Use and Quality of Movement scales, all in favor of the mCIT group. Discussion and Conclusion The data affirm previous findings suggesting that this reimbursable, outpatient protocol increases more affected arm use and function. Magnitude of changes was consistent with those reported in more intense protocols, such as constraint-induced therapy.


2013 ◽  
Vol 38 (1) ◽  
pp. 21-26 ◽  
Author(s):  
Gustav Jarl ◽  
Marie Holmefur ◽  
Liselotte MN Hermansson

Background:The Orthotics and Prosthetics Users’ Survey consists of five modules to assess outcomes of orthotic and prosthetic interventions: lower extremity functional status, upper extremity functional status, client satisfaction with device, client satisfaction with services and health-related quality of life.Objectives:To investigate the test–retest reliability and calculate the smallest detectable difference for all modules of the Swedish Orthotics and Prosthetics Users’ Survey.Study design:Test–retest reliability study design.Methods:A total of 69 patients at a Department of Prosthetics and Orthotics completed Orthotics and Prosthetics Users’ Survey on two occasions separated by a 2-week interval, giving 18 answers on lower extremity functional status, 41 on upper extremity functional status, 53 on client satisfaction with device, 12 on client satisfaction with services and 67 answers on health-related quality of life. Raw scores were converted into Orthotics and Prosthetics Users’ Survey units on a 0–100 scale. Intra-class correlation coefficients, Bland–Altman plots, common person linking plots and t-tests of person mean measures were used to investigate the reliability. The 95% confidence level smallest detectable differences were calculated.Results:The intra-class correlation coefficients ranged from 0.77 to 0.96 for the modules, and no systematic differences were detected between the response occasions. The smallest detectable differences ranged from 7.4 to 16.6 units.Conclusions:The test–retest reliability was satisfactory for all Orthotics and Prosthetics Users’ Survey modules. The smallest detectable difference was large on all modules except the health-related quality of life module.Clinical relevanceThe Orthotics and Prosthetics Users’ Survey modules are reliable and, thus, can be recommended for repeated measurements of patients over time. Relatively large changes are needed to achieve statistical significance when assessing individual patients.


2018 ◽  
Vol 21 (2) ◽  
pp. 84-94 ◽  
Author(s):  
Cory E Noble ◽  
Lesley M Wiseman-Orr ◽  
Marian E Scott ◽  
Andrea M Nolan ◽  
Jacky Reid

Objectives The objective of this study was to develop a valid, reliable, web-based generic feline health-related quality-of-life (HRQoL) questionnaire instrument to measure the affective impact of chronic disease. Methods A large initial item pool, obtained through interviews with cat owners, was reduced using predetermined criteria, survey scores for relevance and clarity, and the ability of individual items to discriminate between healthy and sick cats when owners completed a prototype questionnaire. Using these data, factor analysis was used to derive a scoring algorithm and provide evidence for factorial validity. Validity was demonstrated further in a field trial using a ‘known groups’ approach (sick vs healthy cats will have a different HRQoL profile, and the HRQoL profile of cats will deteriorate as comorbidities increase). Test–retest reliability was assessed using intra-class correlation coefficients (ICCs). Results In total, 165 items were reduced to 20 and, on the basis of a factor analysis that explained 72.3% of the variation in scores input by 71 owners of 30 healthy and 41 sick cats using the prototype, these were allocated to three domains (vitality, comfort and emotional wellbeing [EWB]) with a scoring algorithm derived using item loadings. Subsequently, the owners of 36 healthy and 58 sick cats completed one or two (n = 48) assessments. Median scores (healthy vs sick) for all domains were significantly different ( P <0.001), 78% of cats were correctly classified as healthy or sick and for comorbidities the correlation coefficients were moderate (vitality 0.64; comfort 0.63; EWB 0.50). Test–retest reliability was good (ICC vitality 0.635; comfort 0.716; EWB 0.853). Conclusions and relevance This study provides initial evidence for the validity and reliability of a novel HRQoL instrument to aid the assessment and management of chronic diseases of cats.


2020 ◽  
Vol 9 (9) ◽  
pp. 2992
Author(s):  
Rocío Palomo-Carrión ◽  
Elena Pinero-Pinto ◽  
Sara Ando-LaFuente ◽  
Asunción Ferri-Morales ◽  
Elisabeth Bravo-Esteban ◽  
...  

Children with hemiplegia have lower spontaneous use and quality of movement in the affected upper limb. The modified constraint-induced movement therapy (mCIMT) is applied to improve the affected upper limb function. The objective of this study was to study the efficacy of unaffected hand containment to obtain changes in the function of the affected upper limb after applying two unimanual therapies. A randomized controlled pilot study was performed with 16 children diagnosed with congenital infantile hemiplegia, with eight children randomized in each group (average age: 5.54 years; SD: 1.55). mCIMT and unimanual therapy without containment (UTWC) were applied, with a total of 50 h distributed in five weeks (two h/per day). Two assessments were performed (pre- and post-treatment) to evaluate the affected upper limb spontaneous use, measured with the Shiners Hospital Upper Extremity Evaluation (SHUEE), and the quality of movement, measured with the Quality of Upper Extremity Skills Test (QUEST scale). The progression of the variables was different in both groups. The results are expressed in the median of the improvement percent and interquartile range (IQR). The spontaneous use analysis showed an improvement percent of 31.65 (IQR: 2.33, 110.42) in the mCIMT group with respect to 0.00 (IQR: 0.00, 0.00) in the UTWC group. The quality of movement increased in the mCIMT and UTWC groups, 24.21 (IQR: 13.44, 50.39), 1.34 (IQR: 0.00, 4.75), respectively and the greatest increase was obtained in the grasp variable for both groups. The use of unaffected hand containment in mCIMT would produce improvements in the affected upper limb functionality in children with hemiplegia (4–8 years old) compared to the same protocol without containment (UTWC).


Author(s):  
Rocío Palomo-Carrión ◽  
Rita-Pilar Romero-Galisteo ◽  
Elena Piñero-Pinto ◽  
Purificación López-Muñoz ◽  
Helena Romay-Barrero ◽  
...  

Objective: To assess the functionality of the affected upper limb in children diagnosed with hemiplegia aged between 4 and 8 years after applying low-intensity modified constraint-induced movement therapy(mCIMT). Methods: Prospective case series study. A mCIMT protocol was applied for five weeks, with two hours of containment per day. The study variables were: quality of movement of the upper limb, spontaneous use, participation of the affected upper limb in activities of daily living, dynamic joint position, grasp-release action, grasp strength, supination and extension elbow movements. Four measurements were performed, using the QUEST scale, the SHUEE Evaluation, a hand dynamometer and a goniometer. Results: The sample was composed of 8 children with moderate manual ability. Statistically significant differences were detected in all the studied variables (p&amp;lt;0.05). The greatest increase occurred in spontaneous use from assessment 1-4 (p = 0.01), reaching 88.87% active participation in bimanual tasks. The quality of movement of the upper limb obtained a significant value due to the increase in dissociated movements and grasp (p = 0.01). Conclusion: A low dose (50 hours) of mCIMT increased the functionality of children diagnosed with congenital hemiplegia between 4 and 8 years of age with moderate manual ability.


2021 ◽  
pp. 1-4
Author(s):  
Jamon Couch ◽  
Marc Sayers ◽  
Tania Pizzari

Context: An imbalance between shoulder internal rotation (IR) and external rotation (ER) strength in athletes is proposed to increase the risk of sustaining a shoulder injury. Hand-held (HHD) and externally fixed dynamometry are reliable forms of assessing shoulder IR and ER strength. A new externally fixed device with an attachable fixed upper-limb mold (The ForceFrame) exists; however, its reliability in measuring shoulder strength is yet to be investigated. Objective: To determine the test–retest reliability of the ForceFrame, with and without the fixed upper-limb mold, in the assessment of shoulder IR and ER strength, as compared with HHD. Design: Test–retest reliability study. Setting: Laboratory, clinical. Participants: Twenty-two healthy and active individuals were recruited from the university community and a private physiotherapy practice. Main Outcome Measures: Maximal isometric shoulder IR and ER strength was measured using the ForceFrame and traditional HHD in neutral and at 90° shoulder abduction. Mean (SD) strength measures were calculated. Test–retest reliability was analyzed using intraclass correlation coefficients (3, 1). The SEM and minimal detectable change were calculated. Results: Good to excellent test–retest reliability was found for all shoulder strength tests across Hand-held dynamometry (HHD) and externally fixed dynamometry (EFD) are reliable forms (intraclass correlation coefficients [3, 1] = .854–.916). The minimal detectable changes ranged between 25.61 and 41.84 N across tests. Test–retest reliability was not affected by the dynamometer or testing position. Conclusions: The results from this study indicate that both the ForceFrame and HHD are suitable for measuring shoulder strength in clinical practice. The use of the fixed upper-limb mold with the ForceFrame does not improve reliability.


2020 ◽  
pp. 1-5
Author(s):  
Gemma N. Parry ◽  
Lee C. Herrington ◽  
Ian G. Horsley ◽  
Ian Gatt

Context: Maximal power describes the ability to immediately produce power with the maximal velocity at the point of release, impact, and/or take off—the greater an athlete’s ability to produce maximal power, the greater the improvement of athletic performance. In reference to boxing performance, regular consistent production of high muscular power during punching is considered an essential prerequisite. Despite the importance of upper limb power to athletic performance, presently, there is no gold standard test for upper limb force development performance. Objective: To investigate the test–retest reliability of the force plate–derived measures of countermovement push-up in elite boxers. Design: Test–retest design. Setting: High Performance Olympic Training Center. Participants: Eighteen elite Olympic boxers (age = 23 [3] y; height = 1.68 [0.39] m; body mass = 70.0 [17] kg). Intervention: Participants performed 5 repetitions of countermovement push-up trials on FD4000 Forcedeck dual force platforms on 2 separate test occasions 7 days apart. Main Outcome Measures: Peak force, mean force, flight time, rate of force development, impulse, and vertical stiffness of the bilateral and unilateral limbs from the force–time curve. Results: No significant differences between the 2 trial occasions for any of the derived bilateral or unilateral performance measures. Intraclass correlation coefficients indicated moderate to high reliability for performance parameters (intraclass correlation coefficients = .68–.98) and low coefficient of variation (3%–10%) apart from vertical stiffness (coefficient of variation = 16.5%–25%). Mean force demonstrated the greatest reliability (coefficient of variation = 3%). In contrast, no significant differences (P < .001) were noted between left and right limbs (P = .005–.791), or between orthodox or southpaw boxing styles (P = .19–.95). Conclusion: Force platform–derived kinetic bilateral and unilateral parameters of countermovement push-up are reliable measures of upper limb power performance in elite-level boxers; results suggest unilateral differences within the bilateral condition are not the norm for an elite boxing cohort.


2021 ◽  
pp. 154596832110580
Author(s):  
Roni Molad ◽  
Mindy F. Levin

Background Coordination impairments are under-evaluated in patients with stroke due to the lack of validated assessments resulting in an unclear relationship between coordination deficits and functional limitations. Objective Determine the construct validity of the new clinical upper-limb (UL) Interlimb Coordination test (ILC2) in individuals with chronic stroke. Methods Thirteen individuals with stroke, ≥40 years, with ≥30° isolated supination of the more-affected (MAff) arm, who could understand instructions and 13 healthy controls of similar age participated in a cross-sectional study. Participants performed synchronous bilateral anti-phase forearm rotations for 10 seconds in 4 conditions: self-paced internally-paced (IP1), fast internally-paced (IP2), slow externally-paced (EP1), and fast externally-paced (EP2). Primary (continuous relative phase-CRP, cross-correlation, lag) and secondary outcome measures (UL and trunk kinematics) were compared between groups. Results Participants with stroke made slower UL movements than controls in all conditions, except EP1. Cross-correlation coefficients were lower (i.e., closer to 0) in stroke in IP1, but CRP and lag were similar between groups. In IP1 and matched-speed conditions (IP1 for healthy and IP2 for stroke), stroke participants used compensatory trunk and shoulder movements. The synchronicity sub-scale and total scores of ILC2 were related to temporal coordination in IP2. Interlimb Coordination test total score was related to greater shoulder rotation of the MAff arm. Interlimb Coordination test scores were not related to clinical scores. Conclusion Interlimb Coordination test is a valid clinical measure that may be used to objectively assess UL interlimb coordination in individuals with chronic stroke. Further reliability testing is needed to determine the clinical utility of the scale.


Sign in / Sign up

Export Citation Format

Share Document