scholarly journals Effect of denture cleansers on metal ion release and surface roughness of denture base materials

2012 ◽  
Vol 23 (4) ◽  
pp. 387-393 ◽  
Author(s):  
Letícia Resende Davi ◽  
Daniela Nair Borges Felipucci ◽  
Raphael Freitas de Souza ◽  
Osvaldo Luiz Bezzon ◽  
Cláudia Helena Lovato-Silva ◽  
...  

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.

2008 ◽  
Vol 52 (4) ◽  
pp. 501-506 ◽  
Author(s):  
Teruhisa Hirayama ◽  
Marie Koike ◽  
Tadafumi Kurogi ◽  
Akiko Shibata ◽  
Shigeru Nakamura ◽  
...  

Author(s):  
Karibeeran Shanmuga Sundaram ◽  
Gurusami Kiliyappan ◽  
Senthil Kumaran Selvadurai

Laser shock peening (LSP) is one of the innovative technique that produces a compressive residual stress on the surface of metallic materials, thereby significantly increasing its fatigue life in applications where failure is caused by surface-initiated cracks. The specimens were treated with laser shock waves with different processing parameters, and characterization studies were made on treated specimens. The purpose of the present study was to investigate the influence of Nd:YAG laser on commercially pure titanium (CP-Ti) used in prosthetic dental restorations. The treatment influenced change in microstructure, micro hardness, surface roughness, and wear resistance characteristics. Though CP-Ti is considered as an excellent material for dental applications due to its outstanding biocompatibility, it is not suitable when high mastication forces are applied. In the present study, pulsed Nd:YAG laser surface treatment technique was adopted to improve the wear resistance of CP-Ti. The wear test pin specimens of CP-Ti were investment cast with centrifugal titanium casting machine. The wear properties of specimens were evaluated after LSP on a “pin-on-disc” wear testing tribometer, as per ASTM G99-05 standards. The results of the wear experiment showed that the treated laser surface has higher wear resistance, micro hardness, and surface roughness compared to as-cast samples. The improvement of wear resistance may be attributed due to grain refinement imparted by LSP processes. The microstructure, wear surfaces, wear debris, and morphology of the specimen were analyzed by using optical electron microscope, scanning electron microscope, and X-ray diffraction (XRD). The data were compared using ANOVA and post-hoc Tukey tests. The characteristic change resulted in increase in wear resistance and decrease in wear rate. Hence, it is evident that the more reliable and removable partial denture metal frameworks for dental prostheses may find its applications.


2016 ◽  
Vol 60 ◽  
pp. 37-44 ◽  
Author(s):  
Aljomar José Vechiato-Filho ◽  
Isabella da Silva Vieira Marques ◽  
Daniela Micheline dos Santos ◽  
Adaias Oliveira Matos ◽  
Elidiane Cipriano Rangel ◽  
...  

2011 ◽  
Vol 12 (3) ◽  
pp. 179-186
Author(s):  
Adriana Cristina Zavanelli ◽  
Recardo Alexandre Zavanelli ◽  
José Everaldo de Aquino Souza ◽  
Nelson Renato França Alves da Silva ◽  
Paulo Guilherme Coelho ◽  
...  

ABSTRACT Aim There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium- titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut. How to cite this article Souza JEdA, da Silva NRFA, Coelho PG, Zavanelli AC, Ferracioli RCSR, Zavanelli RA. Retention Strength of Cobalt-Chromium vs Nickel-Chromium Titanium vs CP Titanium in a Cast Framework Association of Removable Partial Overdenture. J Contemp Dent Pract 2011;12(3):179-186.


2020 ◽  
Vol 861 ◽  
pp. 23-27
Author(s):  
Wisan Charee ◽  
Viboon Tangwarodomnukun

Underwater laser machining process is a material removal technique that can minimize thermal damage and offer a higher machining rate than the laser ablation in ambient air. This study applied the underwater method associated with a nanosecond pulse laser for turning a commercially pure titanium rod. The effects of laser power, surface speed and number of laser passes on machined depth and surface roughness were investigated in this work. The results revealed that a deeper cut depth and smoother machined surface than those obtained from the laser ablation in ambient air were achievable when the underwater laser turning process was applied. The machined depth and surface roughness were found to significantly increase with the laser power and number of laser passes. The findings of this study can disclose the insight as well as potential of the underwater laser turning process for titanium and other similar metals.


Sign in / Sign up

Export Citation Format

Share Document