NUMERICAL STUDY OF DROPLET-LADEN MIST FILM COOLING EFFECTIVENESS OF CYLINDRICAL HOLES EMBEDDED IN A TRANSVERSE TRENCHE

2018 ◽  
Author(s):  
Maksim A. Pakhomov ◽  
Viktor I. Terekhov
Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

In search of improved cooling of gas turbine blades, the thermal performances of two different film cooling hole geometries (horn-shaped and cylindrical) are investigated in this numerical study. The horn-shaped hole is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. The two hole shapes are evaluated singly and in tandem. The tandem geometry assumes three configurations made by locating the cylindrical hole at three different positions relative to the horn-shaped hole such that their two axes remain parallel to one another. One has the cylindrical hole downstream from the center of the horn-shaped hole, a second has the cylindrical hole to the left of (as seen by the flow emerging from the horn-shaped hole) and at the same streamwise location as the horn-shaped hole (θ = 90°) and the third has an intermediate geometry between those two geometries (downstream and to the left of the horn-shaped hole - θ = 45°). It is shown from the simulation results that the cooling effectiveness values for the θ = 45° and 90° cases are much better than that for θ = 0° (the first case), and the configuration with θ = 45° exhibits the best cooling performance of the three tandem arrangements. These improvements are attributed to the interaction of vortices from the two different holes, which weakens the counter-rotating vortex pairs inherent to film cooling jet to freestream interaction, counteracts with the lift forces, enhances transverse tensile forces and, thus, enlarges the film coverage zone by widening the flow attachment region. Overall, this research reveals that integration of horn-shaped and cylindrical holes provides much better film cooling effectiveness than cases where two cylindrical film cooling holes are applied with the same tandem configuration.


2013 ◽  
Vol 716 ◽  
pp. 699-704 ◽  
Author(s):  
Ping Dai ◽  
Nai Yun Yu

Effects of hole shapes on film cooling effectiveness downstream of one row of film holes at the blade were investigated using a three-dimensional finite volume method and multi-block technique. The present study also received velocity vectors about different hole shapes. The hole geometries studied include standard cylindrical hole and forward diffused shaped hole and converging slot-hole. It was found that the film cooling effectiveness of cylindrical holes obviously declined along with increasing the blowing ratio. Results of the shaped holes configuration present a marked improvement, with a high effectiveness at the lateral area between adjacent holes and effectiveness of the converging slot-hole was superior to other holes in various blowing ratios. The film cooling effectiveness realized by the slot-holes compared to the cylindrical and forward diffused shaped holes was more excelled at downstream of the intersection of the two slot-holes. The converging slot-hole and forward diffused shaped hole can reduce the vortex intensity, and then enhance the film cooling effectiveness.


Author(s):  
Ding Luo ◽  
Ruishan Lu ◽  
Jiang Lei ◽  
Lesley M. Wright

Abstract In this paper film-cooling effectiveness of two rows of cylindrical holes located on the endwall upstream of a vane is investigated numerically. Five different cooling schemes, including three schemes of double rows cylindrical holes (β = −45°, 0°, 45°), and two schemes of Double-jet film cooling (DJFC) holes (β = −45°, 45° and β = 45°, −45°), are arranged on the endwall at four blowing ratios (M = 0.5, 1.0, 1.5, 2.0). Both primary effect (on downstream endwall) and secondary effect (on pressure and suction surfaces) of the endwall film cooling are considered. ICEM is used to mesh the computational domain, and simulation is carried out by ANSYS 14.0. The result shows that cooling jets with compound angles can effectively suppress lifting-off and increase film-cooling effectiveness. In addition, at low blowing ratios, it is difficult for jets no matter what directions to cool the neighborhood of the leading edge and the pressure side due to the effect of horseshoe vortices. However, passage vortices have different effects on the cooling jets with different compound angles which will result in different film coverage on both endwall and airfoil.


2015 ◽  
Vol 3 (2) ◽  
pp. 15-27
Author(s):  
Ahmed A. Imram ◽  
Humam K. Jalghef ◽  
Falah F. Hatem

     The effect of introducing ramp with a cylindrical slot hole on the film cooling effectiveness has been investigated experimentally and numerically. The film cooling effectiveness measurements are obtained experimentally. A test study was performed at a single mainstream with Reynolds number 76600 at three different coolant to mainstream blowing ratios 1.5, 2, and 3. Numerical simulation is introduced to primarily estimate the best ramp configurations and to predict the behavior of the transport phenomena in the region linked closely to the interaction between the coolant air injection and the hot air mainstram flow. The results showed that using ramps with trench cylindrical holes would enhanced the overall film cooling effectiveness by 83.33% compared with baseline model at blowing ratio of 1.5, also  the best overall flim cooling effectevness was obtained at blowing ratio of 2 while it is reduced at blowing ratio of 3.


Author(s):  
Kevin Liu ◽  
Shang-Feng Yang ◽  
Je-Chin Han

A detailed parametric study of film-cooling effectiveness was carried out on a turbine blade platform. The platform was cooled by purge flow from a simulated stator–rotor seal combined with discrete hole film-cooling. The cylindrical holes and laidback fan-shaped holes were accessed in terms of film-cooling effectiveness. This paper focuses on the effect of coolant-to-mainstream density ratio on platform film-cooling (DR = 1 to 2). Other fundamental parameters were also examined in this study—a fixed purge flow of 0.5%, three discrete-hole film-cooling blowing ratios between 1.0 and 2.0, and two freestream turbulence intensities of 4.2% and 10.5%. Experiments were done in a five-blade linear cascade with inlet and exit Mach number of 0.27 and 0.44, respectively. Reynolds number of the mainstream flow was 750,000 and was based on the exit velocity and chord length of the blade. The measurement technique adopted was the conduction-free pressure sensitive paint (PSP) technique. Results indicated that with the same density ratio, shaped holes present higher film-cooling effectiveness and wider film coverage than the cylindrical holes, particularly at higher blowing ratios. The optimum blowing ratio of 1.5 exists for the cylindrical holes, whereas the effectiveness for the shaped holes increases with an increase of blowing ratio. Results also indicate that the platform film-cooling effectiveness increases with density ratio but decreases with turbulence intensity.


2021 ◽  
Vol 143 (2) ◽  
Author(s):  
Fu-qiang Wang ◽  
Jian Pu ◽  
Jian-hua Wang ◽  
Wei-dong Xia

Abstract Film-hole can be often blocked by thermal-barrier coatings (TBCs) spraying, resulting in the variations of aerodynamic and thermal performances of film cooling. In this study, a numerical study of the blockage effect on the film cooling effectiveness of inclined cylindrical-holes was carried out on a concave surface to simulate the airfoil pressure side. Three typical blowing ratios (BRs) of 0.5, 1.0, and 1.5 were chosen at an engine-similar density ratio (DR) of 2.0. Two common inclination angles of 30 deg and 45 deg were designed. The blockage ratios were adjusted from 0 to 20%. The results indicated the blockage could enhance the penetration of film cooling flow to the mainstream. Thus, the averaged effectiveness and coolant coverage area were reduced. Moreover, the pressure loss inside of the hole was increased. With the increase of BR, the decrement of film cooling effectiveness caused by blockage rapidly increased. At BR = 1.5, the decrement could be acquired up to 70% for a blockage ratio of 20%. The decrement of film cooling effectiveness caused by blockage was nearly nonsensitive to the injection angle; however, the larger angle could generate the higher increment of pressure loss caused by blockage. A new design method for the couple scheme of film cooling and TBC was proposed, i.e., increasing the inlet diameter according to the blockage ratio before TBC spraying. In comparison with the original unblocked-hole, the enlarged blocked-hole not only kept the nearly same area-averaged effectiveness but also reduced slightly the pressure loss inside of the hole. Unfortunately, application of enlarged blocked-hole at large BR could lead to a more obvious reduction of effectiveness near hole-exit, in comparison with the original common-hole.


Author(s):  
Timothy W. Repko ◽  
Andrew C. Nix ◽  
James D. Heidmann

An advanced, high-effectiveness film-cooling design, the anti-vortex hole (AVH) has been investigated by several research groups and shown to mitigate or counter the vorticity generated by conventional holes and increase film effectiveness at high blowing ratios and low freestream turbulence levels. [1, 2] The effects of increased turbulence on the AVH geometry were previously investigated and presented by researchers at West Virginia University (WVU), in collaboration with NASA, in a preliminary CFD study [3] on the film effectiveness and net heat flux reduction (NHFR) at high blowing ratio and elevated freestream turbulence levels for the adjacent AVH. The current paper presents the results of an extended numerical parametric study, which attempts to separate the effects of turbulence intensity and length-scale on film cooling effectiveness of the AVH. In the extended study, higher freestream turbulence intensity and larger scale cases were investigated with turbulence intensities of 5, 10 and 20% and length scales based on cooling hole diameter of Λx/dm = 1, 3 and 6. Increasing turbulence intensity was shown to increase the centerline, span-averaged and area-averaged adiabatic film cooling effectiveness. Larger turbulent length scales were shown to have little to no effect on the centerline, span-averaged and area-averaged adiabatic film-cooling effectiveness at lower turbulence levels, but slightly increased effect at the highest turbulence levels investigated.


Author(s):  
Mukesh Prakash Mishra ◽  
A K Sahani ◽  
Sunil Chandel ◽  
R K Mishra

Abstract In the present work numerical study of full coverage film cooling on an adiabatic flat plate is carried out. Cooling performance of three configurations of cylindrical holes is studied with downstream injection, upstream injection and mixed injection. In mixed injection configuration one column of holes inject in downstream direction and the holes in the adjacent column inject in the upstream direction. Numerical simulations are carried out at different velocity ratios and circumferentially averaged value of adiabatic film cooling effectiveness is estimated. Simulation results indicate that the mixed injection configuration has better and more uniform cooling, throughout the perforated plate, than with downstream injection. The difference is greater with increase in the velocity ratio. Configuration with upstream injection gives better cooling than mixed injection at front few rows of cooling holes but it shows poorer performance with downstream injection in the downstream rows of cooling holes. The obtained results from this study can be an invaluable input for highly loaded combustion chambers.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.


Sign in / Sign up

Export Citation Format

Share Document