Effect of Ethanol Wet Bonding Technique on the Durability of Resin- Dentin Bond with Contemporary Adhesive Systems

2015 ◽  
Vol 39 (2) ◽  
pp. 133-142 ◽  
Author(s):  
R Nagpal ◽  
N Manuja ◽  
IK Pandit

Objective: To evaluate the effect of ethanol wet bonding technique on the immediate and long term bond strength of simplified etch and rinse adhesive systems to dentin. Study Design: 96 extracted human permanent molars were ground to expose the flat dentin surface. The teeth were divided into four groups (n=24) according to the adhesives used, either Tetric N Bond or Solobond M and bonding techniques i.e. water wet bonding or ethanol wet bonding (EWB). Composite cylinder was bonded to each specimen using the respective adhesive technique. Ten samples from each group were then tested immediately for shear bond strength evaluation and two samples for SEM analysis. The remaining samples (12) were tested after 6 month storage in distilled water. Results: Upon immediate testing, there was no significant difference in the mean shear bond strength of the groups regardless of the bonding technique or adhesive used. The bond strength fell dramatically in the water wet bonded specimens after 6 months water storage, while the bond strength of both the adhesives was maintained when EWB technique was used. SEM observation revealed good interfacial adaptation in EWB groups even after six months. Conclusion: For both simplified etch and rinse adhesives used, ethanol wet bonding technique led to significant preservation of the resin dentin bond over 6 months.

Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.


Materials ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 2504
Author(s):  
Mohammad Al-Nabulsi ◽  
Alaa Daud ◽  
Cynthia Yiu ◽  
Hanan Omar ◽  
Salvatore Sauro ◽  
...  

Objective: To evaluate the effect of a new application method of bulk-fill flowable composite resin material on bond-strength, nanoleakage, and mechanical properties of dentine bonding agents. Materials and methods: Sound extracted human molars were randomly divided into: manufacturer’s instructions (MI), manual blend 2 mm (MB2), and manual blend 4 mm (MB4). Occlusal enamel was removed and flattened, dentin surfaces were bonded by Prime & Bond universal (Dentsply and Optibond FL, Kerr). For the MI group, adhesives were applied following the manufacturer’s instructions then light-cured. For MB groups, SDR flow+ bulk-fill flowable composite resin was applied in 2- or 4-mm increment then manually rubbed by a micro brush for 15 s with uncured dentine bonding agents and the mixture was light-cured. Composite buildup was fabricated incrementally using Ceram.X One, Dentsply nanohybrid composite resin restorative material. After 24-h water storage, the teeth were sectioned to obtain beams of about 0.8 mm2 for 24-h and thermocycled micro-tensile bond strength at 0.5 mm/min crosshead speed. Degree of conversion was evaluated with micro-Raman spectroscopy. Contraction gaps at 24 h after polymerization were evaluated and atomic force microscopy (AFM) nano-indentation processes were undertaken for measuring the hardness across the interface. Depth of resin penetration was studied using a scanning electron microscope (SEM). Bond strength data was expressed using two-way ANOVA followed by Tukey’s test. Nanoindentation hardness was separately analyzed using one-way ANOVA. Results: Factors “storage F = 6.3” and “application F = 30.11” significantly affected the bond strength to dentine. For Optibond FL, no significant difference in nanoleakage was found in MI/MB4 groups between baseline and aged specimens; significant difference in nanoleakage score was observed in MB2 groups. Confocal microscopy analysis showed MB2 Optibond FL and Prime & Bond universal specimens diffusing within the dentine. Contraction gap was significantly reduced in MB2 specimens in both adhesive systems. Degree of conversion (DC) of the MB2 specimens were numerically more compared to MS1 in both adhesive systems. Conclusion: Present study suggests that the new co-blend technique might have a positive effect on bond strengths of etch-and-rinse adhesives to dentine.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


2017 ◽  
Vol 42 (1) ◽  
pp. 62-72 ◽  
Author(s):  
J Gan ◽  
S Liu ◽  
L Zhou ◽  
Y Wang ◽  
J Guo ◽  
...  

SUMMARY Purpose: To investigate the effect of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser irradiation pretreatment on the long-term bond strength of an etch-and-rinse adhesive to dentin. Methods: Fifty molars were sectioned parallel to the occlusal plane and randomly divided into two groups (n=25 per group): control group (no treatment) and laser group (dentin surfaces were treated with Nd:YAG laser at a setting of 100 mJ/10 Hz). Afterward, resin was bonded to the dentin surface using a two-step etch-and-rinse adhesive (Adper SingleBond 2), and then 150 beams of each group were produced. Each group was divided into three subgroups (n=50 each group): 24 hours of water storage, thermocycling, and NaOCl storage. The microtensile bond strength (MTBS), failure modes, nanoleakage expression, and Masson's trichrome staining were evaluated. An additional 20 molars were sectioned to obtain 2-mm-thick flat dentin slices. These slices were randomly divided into control and laser-treated groups as mentioned previously. Then slices of each group were examined by scanning electron microscopy, attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray diffraction (XRD), and the Knoop hardness test. Results: The results of ATR-FTIR and Masson's trichrome verified that laser irradiation partly removed collagen fibers from the dentin surface; however, no significant difference was found in the Knoop hardness (p&gt;0.05). The XRD result showed similar crystalline structure regardless of laser pretreatment. There is no significant difference in short-term MTBS between control and laser-treated groups (p&gt;0.05); however, long-term MTBS differed between the groups (p&gt;0.05). Furthermore, the laser-treated group showed less silver deposition than the control group after aging (p&lt;0.05). Conclusion: Pretreatment by Nd:YAG laser irradiation appeared to have a positive effect on the adhesive-dentin bonding in vitro test, and the bonding effectiveness could be preserved after aging.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


2015 ◽  
Vol 16 (10) ◽  
pp. 794-799 ◽  
Author(s):  
Maryam Doozandeh ◽  
Milad Mirmohammadi

ABSTRACT Aim This study evaluated the simultaneous effect of extended etching time and casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) containing paste application on shear bond strength (SBS) of etch-and-rinse adhesive to cariesaffected- dentin (CAD). Materials and methods Fifty human third molars were used; 10 normal in group 1 and 40 caries-affected teeth in groups 2 to 5. In the CAD groups, teeth were randomly assigned into four groups (n = 10). In groups 2 and 4, phosphoric acid etching for 15 and 45 seconds was used and in groups 3 and 5, after 15 or 45 seconds etching respectively, CPP-ACP containing paste (MI paste) was applied for 3 minutes. After rinsing, single bond adhesive system and Z250 composite were used for resin composite build-up in all groups. After storage, SBS test was measured at cross head speed of 0.5 mm/min. Data were analyzed using one/two-way ANOVA and Tukey HSD test (α = 0.05). Results Normal dentin groups showed the highest SBS among different groups. There was a statistically significant difference between different etching times in CAD groups (p < 0.05), but there were no significant differences between SBS of SB adhesive to CAD with or without CPP-ACP pretreated in both etching times. Most of the failure modes were adhesive except in groups 1 and 5 which cohesive failure in composite was also observed. Conclusion The results of our study indicated that extended etching time up to 45 seconds could enhance the SBS of CAD and approach nearly to SBS of normal dentin. Moreover, MI paste pretreatment had not significant effect on SBS of etchand- rinse adhesive in CAD. Clinical significance Simultaneous application of extended etching time and CPP-ACP containing paste may be a suggested method in increasing the SBS of adhesive to CAD. How to cite this article Doozandeh M, Firouzmandi M, Mirmohammadi M. The Simultaneous Effect of Extended Etching Time and Casein Phosphopeptide-Amorphous Calcium Phosphate containing Paste Application on Shear Bond Strength of Etch-and-rinse Adhesive to Caries-affected Dentin. J Contemp Dent Pract 2015;16(10):794-799.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


2019 ◽  
Vol 13 (2) ◽  
pp. 103-108
Author(s):  
Serdar Akarsu ◽  
Suleyman Kutalmış Buyuk ◽  
Ahmet Serkan Kucukekenci

Background. The temperature might affect the physical and mechanical properties of adhesive materials by reducing the polymerization rate. The present study aimed to evaluate the effect of temperature on the shear bond strength of metallic orthodontic brackets using various adhesive resin systems. Methods. Extracted human premolar teeth were randomly assigned to 8 groups (n=10) for bonding with the two available orthodontics adhesive systems (Transbond XT and NeoBond) at different temperatures: refrigeration temperature (4°C), room temperature (20°C), human body temperature (36°C) and high temperature (55°C). The shear bond strength (SBS) test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min. The adhesive remnant index (ARI) was assigned to the fractured orthodontic brackets. Data were analyzed with one-way ANOVA, post hoc Tukey tests and independent t-test. Results. Transbond XT exhibited higher SBS values compared to Neobond at all the tested temperatures; however, a statistically significant difference was not observed (P>0.05). The SBS results were minimum at 4°C and maximum at 36°C in both the adhesive groups (P<0.05). Conclusion. Pre-heating orthodontic adhesives up to the body temperature prior to bonding the brackets in orthodontic treatment increased the bond strength of orthodontic brackets.


2019 ◽  
Vol 8 (1) ◽  
pp. 20
Author(s):  
Fara Dwiyanti ◽  
Ruslan Effendy ◽  
Setyabudi Setyabudi

Background: Composite resins are widely used today to replace lost tooth structure. Bonding between dentin and resin is a complex process that is influenced by several factors; one of which is ambient humidity. During drying after acid etching, it is recommended not to leave the surface of preparation too dry or too wet. If the surface is too dry, collagen will shrink and collapse. As a result, the bonding material cannot penetrate into the cavity between the fibers. If the dentine is too wet, the bonding material will also be difficult to bind with the collagen, either chemically or mechanically. The amount of water around the collagen closely correlates with the moisture created around the dentin surface during the drying process and also whether or not a rubber dam was used during the preparation process. This study is aimed to compare water wet bonding and ethanol wet bonding technique to control humidity. One way of measuring the strength of bonding is to measure shear strength. Purpose: to compare water wet-bonding and ethanol wet-bonding technique.Materials and Methods: 32 samples of bovine teeth incisors were randomly divided into 2 group. Each group consists of sixteen samples. Group 1 is treated with water wet-bonding,group 2 is treated with ethanol wet-bonding. Results: There is significant difference between group 1 and group 2. Conclusion: Shear bond strength of the composite resin bonding on dentin with ethanol wet-bonding technique is higher than the shear bond strength of the composite bonding on dentin with water wet-bonding.


Sign in / Sign up

Export Citation Format

Share Document