Testing of an Evaporative Cooling System That Supplies Air Near the Dew Point Temperature

Author(s):  
Frank Bruno
Author(s):  
I Nyoman Suprapta Winaya ◽  
Hendra Wijaksana ◽  
Made Sucipta ◽  
Ainul Ghurri

The high energy consumption of compressor based cooling system has prompted the researchers to study and develop non-compressor based cooling system that less energy consumption, less environment damaging but still has high enough cooling performances. Indirect and semi indirect evaporative cooling system is the feasible non-compressor based cooling systems that can reach the cooling performance required. This two evaporative cooling system has some different in construction, porous material used, airflow scheme and secondary air cooling method used for various applications. This paper would report the cooling performances achieved by those two cooling system in terms of cooling efficiency, cooling capacity, wet bulb effectiveness, dew point effectiveness, and temperature drop. Porous material used in indirect and semi-indirect evaporative cooling would be highlighted in terms of their type, size, thickness and any other feature. The introduction of nanopore skinless bamboo potency as a new porous material for either indirect or semi-indirect evaporative cooling would be described. In the future study of nanopore skinless bamboo, a surface morphology and several hygrothermal test including sorption, water vapor transmission, thermal conductivity test would be applied, before it utilize as a new porous material for direct or semi indirect evaporative cooling.


Processes ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 332
Author(s):  
Yuanyuan Zhou ◽  
Zhen Yan ◽  
Ming Gao ◽  
Qiumin Dai ◽  
Yanshun Yu

An indirect evaporative cooling system combining with thermoelectric cooling technology (i.e., TIEC system) is proposed, in which a counter-flow plate-fin indirect evaporative cooler is inserted with thermoelectric cooling (i.e., TEC) modules. In hot and humid climate, condensation may occur on the dry channel surface of the cooler. For the TIEC system, with the aid of TEC technology, the surface temperature of the dry channel can be much lower than that of a traditional indirect evaporative cooler, thus, the condensation from the primary air is more likely to take place. A numerical model of this novel TIEC system is developed with specifically taking condensation from primary air into account. Detailed performance analysis of the TIEC system is carried out. Analytical results found that the condensation from primary air reduces the dew point effectiveness by up to 45.0% by weakening the sensible heat transfer but increases the coefficient of performance by up to 62.2% by increasing the latent heat transfer, under given conditions. The effects of main operating conditions, such as the electrical current I and number n of TEC modules, inlet temperature Tp,i, humidity ratio RHp and velocity Vp of the primary air, and the mass flow rate ratio x of secondary to primary air, are investigated under non-condensation and condensation states. It is shown that condensate is more easily produced under higher I, n, Tp,i, RHp, x and lower Vp.


2021 ◽  
pp. 1420326X2110457
Author(s):  
Enrique Mitz-Hernandez ◽  
Miguel Gijón-Rivera ◽  
Carlos I. Rivera-Solorio

A numerical heat and mass transfer model with thermophysical properties dependent on the temperature, humidity ratio and atmospheric pressure was developed. The numerical model was verified and validated against literature, and it showed good agreements. The pseudo-transient model provides a low-cost computational tool to evaluate the potential and performance of a dew point evaporative cooling system for a wide range of extreme climate conditions (BWh, BSh, Cw and Aw from Köppen classification). A parametric analysis of different operational and design conditions in the evaporative cooler was conducted. Results show that there is an optimal channel length for given climatic conditions. The Dew-point evaporative cooling (DPEC) system showed that the best thermal performance corresponds to the climate very arid (Hermosillo – BWh) with 4018 comfort hours (83.1%) followed by the climate arid (Monterrey – BSh) with 3470 comfort hours (90.9%), the mild climate (Puebla – Cw) with 295 comfort hours (100%) and the warm climate (Cancun – Aw) with 3452 comfort hours (62.3%). Finally, an engineering correlation for constant atmospheric pressure and channel length was obtained ([Formula: see text] of 93%).


2016 ◽  
Vol 109 ◽  
pp. 153-165 ◽  
Author(s):  
J. Lin ◽  
K. Thu ◽  
T.D. Bui ◽  
R.Z. Wang ◽  
K.C. Ng ◽  
...  

Energy ◽  
2016 ◽  
Vol 113 ◽  
pp. 172-185 ◽  
Author(s):  
J. Lin ◽  
K. Thu ◽  
T.D. Bui ◽  
R.Z. Wang ◽  
K.C. Ng ◽  
...  

Author(s):  
Hendra Wijaksana ◽  
I. Nyoman Suprapta Winaya ◽  
Made Sucipta ◽  
Ainul Ghurri

The high energy consumption of compressor-based cooling system has prompted the researchers to study and develop non-compressor-based cooling system that less energy consumption, less environment damaging but still has high enough cooling performances. Indirect and semi indirect evaporative cooling system is the feasible non-compressor-based cooling systems that can reach the cooling performance required. These two evaporative cooling systems has some different in construction, porous material used, airflow scheme and secondary air-cooling method used for various applications. This paper would report the cooling performances achieved by those two-cooling systems in terms of cooling efficiency, cooling capacity, wet bulb effectiveness, dew point effectiveness, and temperature drop. Porous material used in indirect and semi-indirect evaporative cooling would be highlighted in terms of their type, size, thickness and any other feature. The introduction of nanopore skinless bamboo potency as a new porous material for either indirect or semi-indirect evaporative cooling would be described. In the future study of nanopore skinless bamboo, a surface morphology and several hygrothermal test including sorption, water vapor transmission, thermal conductivity test would be applied, before it utilizes as a new porous material for direct or semi indirect evaporative cooling.