scholarly journals Evaluation of endometrial pathology in women with postmenopausal bleeding by saline infusion sonography and hysteroscopy

Author(s):  
Shikha Bharti ◽  
Rupali Dewan

Background: Postmenopausal bleeding (PMB) is a common problem representing 5% of all gynaecological outpatient attendance. Objective of this study was to determine diagnostic performance of saline infusion sonography and hysteroscopy for evaluation of endometrial lesions in postmenopausal bleeding.Methods: Being a prospective cross-sectional study, the present study was conducted on 46 postmenopausal women with bleeding, admitted to department of obstetrics and gynecology VMMC and Safdarjang Hospital, New Delhi, India. After TVS, all patients with ET >4 mm underwent SIS and then scheduled for hysteroscopy when there was no active bleeding. Sensitivity, specificity, positive predictive value and negative predictive value were calculated to compare the diagnostic accuracy of SIS and hysteroscopy.Results: Most commonly found endometrial lesions were polyp (39.13%) and endometrial hyperplasia (28.26%) among our study population consisting of 46 postmenopausal women (mean age 56.72±6.6 years). Overall sensitivity rates were 86.84% for SIS and 97.37% for hysteroscopy, while the overall specificity rates were 50% for both SIS and hysteroscopy. Hysteroscopy had PPV and NPV of 90.24% and 80% respectively whereas PPV and NPV were 89.19% and 44.44% for SIS.Conclusions: As an easy to perform, safe and well tolerated procedure yielding high diagnostic accuracy, SIS seems to be comparable to hysteroscopy for endometrial evaluation.

2012 ◽  
Vol 20 (01) ◽  
pp. 132-138
Author(s):  
MUHAMMAD ATIF ◽  
MUHAMMAD ABDULLAH ◽  
MUHAMMAD JAVAD YOUSAF ◽  
Khalid Buland

Objective: To compare the accuracy of Upper lip bite test with modified Mallampati classification for predicting the difficultlaryngoscopic intubation. Study Design: Cross sectional Study. Place and duration of study: The study was carried out at Department ofAnaesthesiology, Intensive Care and Pain management, Combined Military hospital, Rawalpindi from September 2008 to August 2009.Patients and Methods: Four hundred patients undergoing elective surgery meeting the inclusion/exclusion criteria were enrolled afterwritten informed consent. The airways of the patients were evaluated by using the modified Mallampati classification (MMP) and theUpper lip bite test (ULBT). MMP class 3 or 4 and ULBT class 3 were considered as indicators of difficult intubation. The laryngeal view wasgraded by Cormack and Lehane classification (Gold standard). Grade 1 or 2 was considered to represent easy intubation and grade 3 or 4to represent difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy werecalculated for both the tests separately by using the 2×2 table. Results: ULBT had a higher accuracy of 94%, specificity of 99.2% andpositive predictive value 70% compared to MMP accuracy of 82.7%, specificity of 84.4% and positive predictive value of 22.7%.Conclusions: The diagnostic accuracy of the Upper lip bite test was more than the modified Mallampati classification. We suggest that itbe compared with the other prevailing tests as well which are often used to assess difficult intubations.


2021 ◽  
Vol 20 (3) ◽  
Author(s):  
Adi Syazni Muhammed ◽  
Randeep Singh ◽  
Shahrun Niza Abdullah Suhaimi ◽  
Nani Harlina Muhammad Latar

INTRODUCTION: This study aims to evaluate the diagnostic reliability of the American College of Radiology Thyroid Imaging Report and Data System (ACR-TIRADS) and Total Malignancy Score (TMS) scoring system, in differentiating benign and malignant thyroid nodules. MATERIALS AND METHODS: This is a cross-sectional study involving patients with thyroid nodules treated at Hospital Canselor Tuanku Muhriz from October 2017 until October 2019. Ultrasound findings were scored according to the ACR[1]TIRADS and TMS scoring system. They were then correlated with the FNAC or histopathology report. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy of both scoring system were calculated for analysis. RESULTS: A total of 150 patients with 223 thyroid nodules were included. 17% or 38 nodules were found to be malignant. The sensitivity, specificity, PPV, NPV and accuracy of ACR-TIRADS and TMS were 97.37% vs. 84.21 % , 52.97% vs. 62.70%, 29.84% vs. 31.68%, 98.99% vs. 95.08% and 61% vs. 66% respectively. According to the ACR-TIRADS, only hypoechoic nodules was a strong predictor of malignancy. Comparatively, in the TMS, strong predictors of malignancy include single nodule, hypoechogenicity, irregular margin, and nodules with peri and intranodular vascularity. CONCLUSION: Both ACR-TIRADS and TMS score had good diagnostic accuracy in predicting malignant thyroid nodule. TMS is comparable and not inferior to ACR[1]TIRADS however, the latter is more practical for use as growth and Doppler characteristic are not included in the assessment.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ikunda Dionis ◽  
Omary Chillo ◽  
George M. Bwire ◽  
Calvin Ulomi ◽  
Manase Kilonzi ◽  
...  

Abstract Background Jaundice is common among neonates and if untreated can lead to kernicterus. Diagnosing neonatal jaundice (NJ) using Kramer’s method (visual assessment) is considered user-friendly in resource-limited areas. However, there are conflicting findings on reliability of the Kramer’s method in the diagnosis of NJ, particularly of black descent. Therefore, study aimed to determine the accuracy of Kramer’s method in comparison to the total serum bilirubin (TSB) test in the diagnosis of NJ among neonates of black descent in Tanzania. Methods A cross-sectional study was conducted between June and July 2020 at Muhimbili National Hospital (MNH) in Dar es Salaam Tanzania. A total of 315 neonates were recruited consecutively. In each neonate, jaundice was assessed using Kramer’s method and TSB test. NJ A total of 315 neonates were recruited i. A 2 X 2 table was created for the determination of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive and negative likelihood ratios (+LR/−LR), and diagnostic accuracy (effectiveness) of Kramer’s method. Cohen kappa (κ) was used to analyze the agreement between Kramer’s method and TSB. Association between independent variables and presence of jaundice were assessed using the chi-square test and the p < 0.05 was considered to be statistically significant. Results The prevalence of NJ was 49.8% by Kramer’s method and 63.5% by TSB. The Sensitivity, Specificity, PPV, and NPV of Kramer’s method were 70.5, 86.1, 89.8, and 62.6%, respectively. The +LR and –LR were 5.07 and 0.34, respectively. The diagnostic accuracy of Kramer’s method was 76.1%. There was a moderate agreement between Kramer’s method and TSB results (κ = 0.524, P<0.001). No significant relationship was observed between the independent variables and the presence of NJ. Conclusion Kramer has a good positive predictive value. However, due to low sensitivity and NPV one cannot say that overall predictive ability is good. Also, clinical assessment by Kramer’s method should not be used for screening of NJ. Further studies are needed to investigate the utility of other non-invasive techniques in detecting NJ among neonates of black descent.


2020 ◽  
Vol 36 (4) ◽  
Author(s):  
Hina Hanif ◽  
Sohail Ahmed Khan ◽  
Sobia Muneer ◽  
Syed Omair Adil

Objective: To evaluate the diagnostic accuracy of ultrasound in obstructive jaundice taking MRCP as gold standard. Methods: This cross-sectional study was conducted at Dow Institute of Radiology (DIR), Dow University of Health Sciences (DUHS), Karachi from 2nd May 2018 till 2nd November 2018. Both male and female patients aged 30 to 80 years with suspected obstructive jaundice were included. Patients already diagnosed with obstructive jaundice were excluded. MRCP and ultrasound were performed in suspected patients. Diagnostic accuracy including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of obstructive jaundice were calculated using contingency tables using MRCP findings as gold standard. Results: Mean age of the patients was 54.73 ± 12.65 years. In causes of obstruction, choledocholothiasis was responsible for 85 (35.1%), stricture 61 (25.2%), carcinoma of head of pancreas 39 (16.1%), periampullary carcinoma 21 (8.7%), cholangiocarcinoma 10 (4.1%) and gallbladder carcinoma 26 (10.7%) of the cases. Diagnostic accuracy of ultrasound in obstructive jaundice taking MRCP findings as gold standard showed sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV) and overall diagnostic accuracy as 84.57%, 79.10%, 91.36%, 66.25% and 83.06%. Conclusion: Ultrasound has a high sensitivity, moderate specificity, and high diagnostic accuracy in diagnosis of obstructive jaundice. doi: https://doi.org/10.12669/pjms.36.4.1665 How to cite this:Hanif H, Khan SA, Muneer S, Adil SO. Diagnostic accuracy of ultrasound in evaluation of obstructive jaundice with MRCP as gold standard. Pak J Med Sci. 2020;36(4):---------. doi: https://doi.org/10.12669/pjms.36.4.1665 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


2020 ◽  
Vol 103 (6) ◽  
pp. 585-593

Objective: To evaluate the accuracy of transvaginal ultrasonography (TVS) and saline infusion sonography (SIS) in use for the diagnosis of endometrial polyps and submucous myoma compared to hysteroscopy. Histopathology was considered as the gold standard for final diagnosis. Materials and Methods: The present retrospective study was conducted at Bhumibol Adulyadej Hospital, Bangkok, Thailand between January 2014 and December 2017. Medical records of 150 patients who attended for hysteroscopy and histopathological diagnosis were reviewed. The accuracy of TVS and SIS for the diagnosis of endometrial polyps and submucous myoma were determined. Results: Out of 150 enrolled cases, endometrial polyp was the most frequent hysteroscopic finding in participants of the present study (92/150). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of TVS, SIS, and hysteroscopy compared to pathologic reports for detection endometrial polyps were 71.7% versus 93.5% versus 97.8%, 38.5% versus 52.2% versus 68.2%, 80.5% versus 88.7% versus 92.8%, 27.8% versus 66.7% versus 88.2%, and 64.4% versus 85.2% versus 92.1%, respectively. The sensitivity, specificity, PPV, NPV, and accuracy of TVS, SIS, and hysteroscopy for detection of submucous myoma were 81.6% versus 92.1% versus 94.7%, 66.7% versus 86.9% versus 100%, 77.5% versus 92.1% versus 100%, 72.0% versus 86.9% versus 90.9%, and 75.4% versus 90.2% versus 96.6%, respectively. The kappa value from TVS, SIS, and hysteroscopy when the histopathologic reports were overall intrauterine abnormalities, endometrial polyps and submucous myoma were 0.45/0.43/0.72, 0.77/0.76/0.89, and 0.92/0.92/1.00, respectively. Conclusion: Sensitivity, specificity, PPV, NPV, accuracy, and kappa value of SIS for detecting endometrial polyps and submucous myoma were better than TVS. Keywords: Ultrasonography, Saline infusion sonography, Hysteroscopy, Accuracy


2021 ◽  
Vol 15 (6) ◽  
pp. 1679-1681
Author(s):  
Afaque Ali ◽  
Majid Shaikh ◽  
Ahsanullah . ◽  
Adeel Ahmed ◽  
Abid Ali Sahito ◽  
...  

Objective: To determine the diagnostic accuracy of High-resolution computed tomography (HRCT) chest in detection of covid-19 infection taking PCR as gold standard. Study Design: Cross-sectional study Setting: Radiology department of Tabba Hospital, Karachi. Duration: From March 2019 to September 2020 Material and Methods: All the clinically suspected patients of covid-19, of any age, both genders and those referred to radiology for High-resolution computed tomography (HRCT) chest to detect the covid-19 infection were included. After two days, patients’ PCR reports were collected from the ward, after taking informed consent and permission from head of department. The diagnostic accuracy of HRCT was established with respect to sensitivity, PPV, NPV, and specificity by taking PCR as gold standard. All the information was collected via study proforma. Results: Total 70 patients suspected for COVID-19 were studied, and the patients’ mean age was 58.23±9.52 years. Males were in majority 54(77.1%). As per HRCT findings, COVID-19 infection was positive in 46 patients, however, 48 patients were detected positive for COVID-19 infection as per PCR findings. In the detection of COVID-19 infection, HRCT chest showed sensitivity of 91%, specificity of 90%, PPV of 83%, NPV of 84% and diagnostic accuracy of 94%; by taking PCR as gold standard. Conclusion: High-resolution computed tomography (HRCT) is a reliable diagnostic approach in promptly detecting the COVID-19; with 91% sensitivity, 90% specificity, 83% positive predictive value, 84% negative predictive value and 94% diagnostic accuracy. Keywords: Accuracy, HRCT, COVID-19


2014 ◽  
Vol 39 (2) ◽  
pp. 80-85
Author(s):  
MS Showkat ◽  
S Nabi ◽  
L Khondker ◽  
B Bhowmik ◽  
SN Tushar ◽  
...  

Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. Objective of this study is to evaluate the clinical usefulness of transvaginal ultrasonography (TVS) in pre, peri and post menopausal women suspected to have endometrial carcinoma. This cross sectional study was done with 40 patients who are clinically suspected having thickened endometrium. The study was carried out January 2007 to November 2008 for a period of two years. The patients having endometrial carcinoma diagnosed by TVS was correlated with histopathological diagnosis following collection of the report from the respective cases. Of total 40 cases, 2(5.0%) cases were endometrial carcinoma and 38(95.0%) were negative for endometrial carcinoma respectively in TVS findings. On the other hand 3(7.5%) cases were endometrial carcinoma and 37 (92.5%) cases were negative for endometrial carcinoma in histopathological findings. The validity of TVS in diagnosis of endometrial carcinoma were studied by calculating sensitivity, specificity, accuracy, positive predictive value and negative predictive value, which were 67 percent, 100 percent, 98 percent, 100 percent and 97 percent respectively. As the TVS findings of the present study correlated well with the histopathology findings and the validity test values were higher than observed by others, it can be concluded that TVS is sensitive and accurate modality in the evaluation of endometrial carcinoma. DOI: http://dx.doi.org/10.3329/bmrcb.v39i2.19647 Bangladesh Med Res Counc Bull 2013; 39: 80-85


Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1011
Author(s):  
Sofia Nevander ◽  
Eva Landberg ◽  
Marie Blomberg ◽  
Bertil Ekman ◽  
Caroline Lilliecreutz

Gestational diabetes mellitus (GDM) is a common complication with negative impacts on mother and child. The primary aim of this study was to examine whether plasma glucose cutoffs for GDM diagnosis based on venous sampling can be replaced by cutoffs based on capillary sampling. A prospective cross-sectional study was performed at an antenatal care clinic including 175 pregnant women undergoing an oral glucose tolerance test (OGTT). Duplicate samples were collected by capillary and venous puncture while fasting and 1 h and 2 h after an OGTT. Both samples were analyzed on Accu-Chek Inform II. The cutoffs for a GDM diagnosis using capillary samples were corrected from 5.1 to 5.3 mmol/L for the fasting sample, from 10.0 to 11.1 mmol/L for the 1 h sample, and from 8.5 to 9.4 mmol/L for the 2-h sample using half of the dataset. Applying these cutoffs to the remaining dataset resulted in a sensitivity, specificity, and accuracy of 85.0%, 95.0%, and 90.3%, respectively, with a positive predictive value (PPV) of 83%, an negative predictive value (NPV) of 96%, and a positive negative likelihood ratio (LHR) of 16.4 using capillary sampling for the GDM diagnosis at fasting and 2-h after. Corrected cutoffs and capillary samples can be used for the diagnosis of GDM with maintained diagnostic accuracy using Accu-Chek Inform II.


2021 ◽  
Vol 4 (03) ◽  
Author(s):  
Abaid ur Rehman ◽  
Muhammad Imran Khan ◽  
Omer Sabir ◽  
Muhammad Mohsin Riaz ◽  
Mubashar Dilawar ◽  
...  

The initiation of hemodialysis in patients with chronic kidney disease (CKD) requires vascular access formation. The choice of vascular access for individual patient depends on various factors however arteriovenous fistula (AVF) is conventionally considered to be the vascular access of choice. Once hemodialysis is initiated through a mature AVF, there is an ongoing need for surveillance of the AVF to ensure adequate function and prevent vascular access issues among which flow obstruction (both inflow and outflow) remains the most important. AVF stenosis can potentially lead to inadequate dialysis delivery and thrombosis thus leading to access loss. Physical examination and AVF Doppler ultrasonography (DUS) are useful for evaluation of stenosis in the  arteriovenous connection and the outflow tract. Periodic assessment of the AVF with Static Intra access Pressure (SIAPR) determination may be a reliable means of predicting vascular access stenosis. Material & Methods  A cross sectional study carried out at Department of Nephrology, Fatima Memorial Hospital, Lahore from July 2018 to December 2018. In total 113 patients were included, and all patients underwent SIAPR assessment and Doppler Ultrasound of AVF. Results Mean age of the patients was 56.81±9.38 years, male to female ratio of the patients was 1.8:1. In this study the SIAPR was suggestive of  stenosis in 87(76.99%) patients. The sensitivity, specificity and diagnostic accuracy of SIAPR against Doppler US of the AVF for detection of stenosis was 75.86%, 22.62% & 36.28% respectively Conclusion SIAPR has low specificity and diagnostic accuracy compared to Doppler US for detection of AVF stenosis.


2010 ◽  
Vol 2 (2) ◽  
pp. 133-135 ◽  
Author(s):  
Hema Dhumale ◽  
BR Desai ◽  
Yeshita Pujar ◽  
Bhavana Sherigar ◽  
Shobana Patted

ABSTRACT Objective To compare the diagnostic efficacy of saline infusion sonohysterography (SIS) with hysterolaparoscopy in evaluation of uterine cavity and tubal patency. Methods This prospective one year cross-sectional study was conducted at the assisted reproduction center (ARC), KLES Dr Prabhakar Kore Hospital and Medical Research Centre, Belgaum. A total of 60 patients underwent SIS for evaluation of uterine cavity and tubal patency. Subsequently all patients underwent hysterolaparoscopy with chromopertubation (CPT). Results of SIS and hysterolaparoscopy with chromopertubation were compared. Results For evaluation of uterine cavity, when compared with hysteroscopy, SIS had a sensitivity of 97.8%, specificity of 88.8%, positive predictive value (PPV) of 97.8% and negative predictive value (NPV) of 88.8%. For evaluation of tubal patency when SIS was compared to laparoscopy with CPT, SIS had a sensitivity of 83.3%, specificity of 82.9%, PPV of 42.9% and NPV of 97.5%. Conclusion Saline infusion sonohysterography is a noninvasive, simple, easy and cost-effective procedure. SIS is more sensitive and specific for evaluation of uterine cavity as compared to evaluation of tubal patency.


Sign in / Sign up

Export Citation Format

Share Document