scholarly journals Study of ascitic fluid cytology in ovarian tumors

Author(s):  
Chandralekha Janagam ◽  
Bhagyalakshmi Atla

Background: The objectives of this study were to examine the validity of ascitic fluid cytology in the detection of pathological findings, to examine the percentage of false positive and false negative results in the cytology of ascitic fluid and to determine the validity of peritoneal cytology in relation to the histopathological type of the ovarian tumour.Methods: This retrospective study, over a period of 6 months, included 106 peritoneal cytology findings. The experimental group included 106 cytology findings obtained from patients who presented with an abdominal lump/mass with ascites and diagnosed with ovarian tumors clinically. They included 88 benign ovarian tumours (83%) and 18 malignant ovarian tumors (17%). Patients with other causes of ascites were excluded from the study.Results: The sensitivity of peritoneal cytology is 90%, specificity is 96.5%, positive predictive value is 85.7%, and negative predictive value is 97.6%. In 1.8% of patients, the peritoneal cytology showed false negative results, while in 2.8%, the results were false positive. False negative results were found in one case of teratoma with squamous cell carcinoma and one case of yolk sac tumor. False positive results were found in 2 cases of tuberculous-salpingo- oophoritis and one case of chronic salpingo-oophoritis due to reactive mesothelial proliferation, mistaken for adenocarcinoma.Conclusions: Peritoneal cytology of ascitic fluid is highly specific and sensitive for detection of ovarian malignancies, particularly in grade 3 and grade 4 disease, since most of the patients with ovarian malignancies present to us at advanced stage of the disease.

2019 ◽  
Vol 130 (3) ◽  
pp. 936-948 ◽  
Author(s):  
Jaewoo Chung ◽  
Wonhyoung Park ◽  
Seok Ho Hong ◽  
Jung Cheol Park ◽  
Jae Sung Ahn ◽  
...  

OBJECTIVESomatosensory and motor evoked potentials (SEPs and MEPs) are often used to prevent ischemic complications during aneurysm surgeries. However, surgeons often encounter cases with suspicious false-positive and false-negative results from intraoperative evoked potential (EP) monitoring, but the incidence and possible causes for these results are not well established. The aim of this study was to investigate the efficacy and reliability of EP monitoring in the microsurgical treatment of intracranial aneurysms by evaluating false-positive and false-negative cases.METHODSFrom January 2012 to April 2016, 1514 patients underwent surgery for unruptured intracranial aneurysms (UIAs) with EP monitoring at the authors’ institution. An EP amplitude decrease of 50% or greater compared with the baseline amplitude was defined as a significant EP change. Correlations between immediate postoperative motor weakness and EP monitoring results were retrospectively reviewed. The authors calculated the sensitivity, specificity, and positive and negative predictive values of intraoperative MEP monitoring, as well as the incidence of false-positive and false-negative results.RESULTSEighteen (1.19%) of the 1514 patients had a symptomatic infarction, and 4 (0.26%) had a symptomatic hemorrhage. A total of 15 patients showed motor weakness, with the weakness detected on the immediate postoperative motor function test in 10 of these cases. Fifteen false-positive cases (0.99%) and 8 false-negative cases (0.53%) were reported. Therefore, MEP during UIA surgery resulted in a sensitivity of 0.10, specificity of 0.94, positive predictive value of 0.01, and negative predictive value of 0.99.CONCLUSIONSIntraoperative EP monitoring has high specificity and negative predictive value. Both false-positive and false-negative findings were present. However, it is likely that a more meticulously designed protocol will make EP monitoring a better surrogate indicator of possible ischemic neurological deficits.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2013 ◽  
Vol 57 (9) ◽  
pp. 4578-4580 ◽  
Author(s):  
Nathalie Tijet ◽  
David Boyd ◽  
Samir N. Patel ◽  
Michael R. Mulvey ◽  
Roberto G. Melano

ABSTRACTThe Carba NP test was evaluated against a panel of 244 carbapenemase- and non-carbapenemase-producingEnterobacteriaceaeandPseudomonas aeruginosaisolates. We confirmed the 100% specificity and positive predictive value of the test, but the sensitivity and negative predictive value were 72.5% and 69.2%, respectively, and increased to 80% and 77.3%, respectively, using a more concentrated bacterial extract. False-negative results were associated with mucoid strains or linked to enzymes with low carbapenemase activity, particularly OXA-48-like, which has emerged globally in enterobacteria.


PEDIATRICS ◽  
1996 ◽  
Vol 98 (1) ◽  
pp. 41-44
Author(s):  
Judy G. Saslow ◽  
Ernest M. Post ◽  
Carol A. Southard

Objective. As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. Methods. During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. Results. Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 µIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. Conclusions. Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.


2019 ◽  
Vol 5 (2) ◽  
pp. 290-299
Author(s):  
Isabelle Danielle Piec ◽  
Beatrice Tompkins ◽  
William Duncan Fraser

Abstract Background Asfotase alfa (STRENSIQ®, Alexion Pharmaceuticals, Inc.) is the only approved treatment for patients with pediatric-onset hypophosphatasia, a disease caused by a mutation in the tissue-nonspecific alkaline phosphatase (TNSALP) gene. ALP is often used as signaling system in routine immunoassays. Because asfotase alfa contains the active site of the full ALP enzyme, it can catalyze the substrate as the antibody-conjugated ALP would within an assay. Therefore, its presence in a treated patient’s sample may generate false positive or false negative results. We investigated whether the presence of asfotase alfa within a sample induced interference in immunoassays that utilize ALP or alternative detection systems. Methods Asfotase alfa was added to samples at concentrations from 0.08–5 µg/mL and analysed on various immunoassays following manufacturer’s instructions. Results Asfotase alfa was detected in all ALP assays but ALKP1 (RayBiotech). We observed no changes in normetanephrine and noradrenaline (IBL) at any asfotase alfa concentration. However, asfotase alfa notably interfered in an oxytocin (ENZO) assay in nonextracted samples. Extraction using a C18 column eliminated the interference. No interference was observed on automated analyzers using alternative detection system (COBAS fT4 and TSH; Advia Centaur FSH, fT4; Architect LH; FSH). Immulite 2000 fT4, TSH, testosterone and hCG (ALP-based) showed no interference. However, the presence of asfotase alfa resulted in a dose-dependent increase of Troponin I signal. Conclusion The presence of asfotase alfa must be taken into consideration when analyzing blood samples in treated patients to avoid any risk of misinterpretation of false positive/negative results. It is essential that assays be tested for this possible interference.


2019 ◽  
Vol 152 (Supplement_1) ◽  
pp. S147-S147
Author(s):  
Andrew Hall ◽  
Ortega Lopez ◽  
Amy Powers

Abstract Introduction Testing for thrombophilic risk factors is common in patients with thrombosis. However, inpatient hereditary thrombophilia work-ups are prone to false-positive and false-negative results due to concurrent acute phase changes, protein consumption, anticoagulation therapy, and liver disease. A recent ASCP Choosing Wisely guideline recommends against measuring protein C (PC), protein S (PS), or antithrombin III (AT3) to diagnose a hereditary deficiency during an active clotting event. We aimed to review inpatient PC, PS, and AT3 activity assay ordering practices at a tertiary care center. The goal of this study was to determine appropriateness and identify areas for improvement in inpatient thrombophilia ordering practices. Methods A retrospective review of inpatients who underwent thrombophilia testing was performed. Inclusion criteria consisted of adult inpatients with PC, PS, and/or AT3 activity results. Patients for whom AT3 was ordered alone were excluded. The timeframe of testing relative to an acute thrombotic event, anticoagulation therapy, and liver disease was determined via electronic medical record review. Other conditions that can affect PC, PS, or AT3 levels were recorded if noted. Results Over 5 months, 50 inpatients underwent testing for PC, PS, and/or AT3. Testing was performed within 2 weeks of an acute thrombotic event in 92% of patients; 32% received anticoagulation therapy prior to testing and 16% had liver disease. Test results below the reference range were found in the following percentage of patients: 16% PC, 34% PS, and 16% AT3. In total, 23 of 50 (46%) patients had one or more abnormal results; all 23 had potential confounding conditions/drug. Conclusions Inpatient PC, PS, and AT3 testing was frequently performed in clinical settings, which may cause false-positive or false-negative results. This demonstrates the need for increased education and dialogue between the laboratory and clinicians to improve test utilization practices. Potential interventions are currently being analyzed.


1994 ◽  
Vol 56 (1-4) ◽  
pp. 291-292 ◽  
Author(s):  
K.D. Cliff ◽  
J.C.H. Miles ◽  
S.P. Naismith

Abstract Data from the UK national survey of radon in 2300 homes has been re-analysed to determine the uncertainty in seasonal correction factors applied to measurements of less than l year. The required correction factor for each six-month result was calculated from the known annual average for the appropriate home. The seasonal correction factors derived for each month were found to be approximately log-normally distributed, with an average geometric standard deviation of 1.36. Following this initial survey, radon measurements have been made in more than 80,000 homes in southwest England to determine whether they are above the UK radon Action level of 200 Bq.m-3. The measurements were carried out over three months in each case using etched track detectors in two locations in each home, and the results were corrected for the average seasonal variation found in the original UK study of radon in homes. Because of the uncertainty in the seasonal correction factors, households with between 130 and 300 Bq.m-3 were advised to have a second three-month measurement in a different season before deciding whether or not to take remedial action. More than 7000 homes were remonitored for this purpose. The results are analysed to show the number of false positive and false negative results that would have been reported if advice had been based solely on the initial measurement. It is shown that the present scheme results in extremely small numbers of false positive and false negative results.


1997 ◽  
Vol 12 (Suppl_2) ◽  
pp. 312-312
Author(s):  
L. Míguez ◽  
C. Fuster ◽  
M.M. Perez ◽  
M.L. Alegre ◽  
M. Sostoa ◽  
...  

2019 ◽  
Vol 57 (02) ◽  
pp. 133-138
Author(s):  
Eva-Marie Warnken ◽  
Michael Uder ◽  
Hubert Stein ◽  
Michael Wucherer ◽  
Michael Lell ◽  
...  

Abstract Purpose The goal of this study was to evaluate the experience of 11 years of wire-guided forceps biopsy via PTCD in patients with obstructive jaundice. Materials and methods In a retrospective approach, 56 biopsies in 51 patients were analyzed (22 female, 29 male). Data was collected from 2006 to 2016. Mean age was 71 years (range: 34 – 86 years). Data was extracted from dig. Patients’ records (KIS, PACS, RIS) to be analyzed in Microsoft Excel. Results All 56 procedures were technically successful. Stenosis in anastomoses were benign due to scarring in 7 patients and in 9 due to papillitis or others. In 4 patients, results in anastomosis were malignant. In 19 patients without anastomosis, CCC was the diagnosis, thereof 10 klatskin, 9 stenosis in other locations, followed by gastric, pancreatic, and colon carcinoma in 5, 3, and 2 patients. Three patients had a CUP (multimetering in case of more than 1 related category). Overall results were 35 mal. and 16 benign, 76.8 % of all proc. had a correct histopathologic result, and 23.2 % were false negative. Sensitivity was 65.8 %, which results in negative predictive value of 58.1 %. There was no false positive and so specificity was 100 %, as was the positive predictive value. False negative results (no malignancy but clinically and imaging suspect) were corrected by rerunning the procedure, by CT-guided biopsy or by 1 PET-CT. In 1 case the surg. sample brought the result. Minor complications occurred in 8 patients: shivering in 1 case, distinct but hemodynamically not relevant hemobilia in 5 cases, 2 portovenal bleedings. All bleedings were short-term and self-limiting. Conclusion Despite good feasibility, low peri- and post-interv. risk and high validity the forceps biopsy via PTCD is not widely used. For experienced interventionalists, it is an effective method for obtaining histology.


Sign in / Sign up

Export Citation Format

Share Document