scholarly journals 3D Printed Custom Orthotic Device Development: A Student-driven Project

2018 ◽  
Author(s):  
April Krivoniak ◽  
Arif Sirinterlikci
2016 ◽  
Vol 19 (7) ◽  
pp. A564
Author(s):  
M Alband ◽  
RM Lee ◽  
M Penny ◽  
S Brocchini ◽  
ST Hilton

2017 ◽  
Author(s):  
Lokesh Saharan ◽  
Ashvath Sharma ◽  
Monica Jung de Andrade ◽  
Ray H. Baughman ◽  
Yonas Tadesse
Keyword(s):  

Micromachines ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 825
Author(s):  
Panagiotis Karayannis ◽  
Fotini Petrakli ◽  
Anastasia Gkika ◽  
Elias P. Koumoulos

The aim of this study is to provide a detailed strategy for Safe-by-Design (SbD) 3D-printed lab-on-a-chip (LOC) device manufacturing, using Fused Filament Fabrication (FFF) technology. First, the applicability of FFF in lab-on-a-chip device development is briefly discussed. Subsequently, a methodology to categorize, identify and implement SbD measures for FFF is suggested. Furthermore, the most crucial health risks involved in FFF processes are examined, placing the focus on the examination of ultrafine particle (UFP) and Volatile Organic Compound (VOC) emission hazards. Thus, a SbD scheme for lab-on-a-chip manufacturing is provided, while also taking into account process optimization for obtaining satisfactory printed LOC quality. This work can serve as a guideline for the effective application of FFF technology for lab-on-a-chip manufacturing through the safest applicable way, towards a continuous effort to support sustainable development of lab-on-a-chip devices through cost-effective means.


Author(s):  
Panagiotis Karayannis ◽  
Fotini Petrakli ◽  
Anastasia Gkika ◽  
Elias Koumoulos

The aim of this study is to provide a detailed strategy for Safe-by-Design (SbD) 3D printed lab-on-a-chip (LOC) device manufacturing, using Fused Filament Fabrication (FFF) technology. At first, the applicability of FFF in lab-on-a-chip device development is briefly discussed. Subsequently, a methodology to categorize, identify and implement SbD measures for FFF is suggested. Furthermore, the most crucial health risks involved in FFF processes are examined, placing the focus on the examination of ultrafine particle (UFP) and Volatile Organic Compound (VOC) emission hazards. Thus, a SbD scheme for lab-on-a-chip manufacturing is provided, while also taking into account process optimization for obtaining satisfactory printed LOC quality. This work can serve as a guideline for the effective application of FFF technology for lab-on-a-chip manufacturing through the safest applicable way, towards a continuous effort to support sustainable development of lab-on-a-chip devices through cost-effective means.


2019 ◽  
Vol 13 (3) ◽  
Author(s):  
Saikat Sahoo ◽  
Aditya Jain ◽  
Dilip Kumar Pratihar

The task of a powered knee orthotic device (PKOD) is to assist the knee joint so that its natural behavior can be restored. The key features of a PKOD that may help to regain such characteristics are low power consumption, fast response, compactness, and lightweight. This study proposes a novel design of PKOD, where we have focused on the betterment of the mentioned features with the help of a new mechanism, namely a four-bar controlled compliance actuator (FCCA). In FCCA, instead of using the widely used screw transmission mechanism, a four-bar mechanism is used to modify the joint's angular deviation and stiffness. The main advantages of using FCCA over other existing mechanisms are to reduce the power consumption by amplification of input motor torque and to achieve a faster response at the same time, and these are achieved by utilizing a simple four-bar mechanism. In the proposed design, FCCA controls both the stiffness of the artificial knee joint using a compliance mechanism as well as knee flexion with the help of a pulley arrangement. A three-dimensional (3D)-printed prototype of the proposed design has been developed, after optimizing the inherent design parameters. Simulation and experimental analysis are carried out in order to justify the performance of the proposed PKOD. The results have shown strong agreement with that obtained using analytical study and optimization. Moreover, the torque amplification is achieved, as desired.


Author(s):  
Priyanka Madaan ◽  
Nirmal Raj Gopinathan ◽  
Lokesh Saini ◽  
Aarti Chauhan ◽  
Harpreet Singh ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3413
Author(s):  
Shah Uddin ◽  
Abkar Sayad ◽  
Jianxiong Chan ◽  
Duc Huynh ◽  
Efstratios Skafidas ◽  
...  

HLA-B*15:02 screening before administering carbamazepine is recommended to prevent life-threatening hypersensitivity. However, the unavailability of a point-of-care device impedes this screening process. Our research group previously developed a two-step HLA-B*15:02 detection technique utilizing loop-mediated isothermal amplification (LAMP) on the tube, which requires two-stage device development to translate into a portable platform. Here, we report a heater-integrated lab-on-a-chip device for the LAMP amplification, which can rapidly detect HLA-B alleles colorimetrically. A gold-patterned micro-sized heater was integrated into a 3D-printed chip, allowing microfluidic pumping, valving, and incubation. The performance of the chip was tested with color dye. Then LAMP assay was conducted with human genomic DNA samples of known HLA-B genotypes in the LAMP-chip parallel with the tube assay. The LAMP-on-chip results showed a complete match with the LAMP-on-tube assay, demonstrating the detection system’s concurrence.


2016 ◽  
Vol 77 (S 02) ◽  
Author(s):  
Hassan Othman ◽  
Sam Evans ◽  
Daniel Morris ◽  
Saty Bhatia ◽  
Caroline Hayhurst

Sign in / Sign up

Export Citation Format

Share Document