scholarly journals Features of using gas turbine units as a source of electricity and heat at mini - thermal power plants

2021 ◽  
Vol 72 (7) ◽  
pp. 89-92
Author(s):  
M.M. Zamaleev ◽  
Yu.V. Zhukova ◽  
A.V. Abramov ◽  
Yu.R. Abaidullina

This article discusses the problem of introducing more resource-intensive methods of generating electricity and heat, the main of which is the use of small-sized gas turbine units (GTU). The creation of a Mini-Thermal Power Plant on the basis of the GTU allows solving the problem of the shortage of heat and electric energy in certain regions, ensuring uninterrupted power supply to the housing and communal sector and industrial enterprises. This is due to the possibility of combined production of heat and electric energy, as well as products and services required in the municipal services of the city. This article presents ways to improve the energy efficiency of thermal power plants through the use of GTU.

2010 ◽  
Vol 7 (2) ◽  
pp. 231-252 ◽  
Author(s):  
Slobodan Vukosavic ◽  
Nikola Popov ◽  
Zeljko Despotovic

Thermal power stations emit significant amounts of fly ash and ultra fine particles into the atmosphere. Electrostatic precipitators (ESP) or electro filters remove flying ashes and fine particles from the flue gas before passing the gas into the chimney. Maximum allowable value of dust is 50 mg/m3 and it requires that the efficiency of the ESPs better than 99 %, which calls for an increase of active surface of the electrodes, hence increasing the filter volume and the weight of steel used for the filter. In previous decades, electrostatic precipitators in thermal power plants were fed by thyristor controlled, single phase fed devices having a high degree of reliability, but with a relatively low collection efficiency, hence requiring large effective surface of the collection plates and a large weight of steel construction in order to achieve the prescribed emission limits. Collection efficiency and energy efficiency of the electrostatic precipitator can be increased by applying high frequency high voltage power supply (HF HV). Electrical engineering faculty of the University of Belgrade (ETF) has developed technology and HF HV equipment for the ESP power supply. This solution was subjected to extensive experimental investigation at TE Morava from 2008 to 2010. High frequency power supply is proven to reduce emission two times in controlled conditions while increasing energy efficiency of the precipitator, compared to the conventional thyristor controlled 50Hz supply. Two high frequency high voltage unit AR70/1000 with parameters 70 kV and 1000 mA are installed at TE Morava and thoroughly testes. It was found that the HF HV power supply of the ESP at TE Morava increases collection efficiency so that emission of fine particles and flying ashes are halved, brought down to only 50 % of the emissions encountered with conventional 50 Hz thyristor driven power supplies. On the basis of this study, conclusion is drawn that the equipment comprising HF HV supplies are the best solution for new ESP installations, as well as for the reconstruction of existing facilities. The paper describes the topology of the HF HV power supply, power management and controls, and brings the most important details of the implementation. It is found that the HF HV solution achieves several significant improvements over the conventional thyristor system. It is possible to provide more precise control of the ESP parameters such as the output voltages and currents. It is also possible to make a rapid increase or decrease in voltage and to effectuate a very fast response to load changes. Due to this advantages it is possible to suppress the supply quickly in the case of sparking, reducing the spark energy and the quantity of ionized gasses produced by the electric arc. Reduction in the spark energy is up to 10 times compared to conventional thyristors solution. This means that the erosion of the electrode system is significantly reduced, and that the quality of the collection plates is preserved for much longer periods. At the same time, lower quantity of ionized gasses produced by the spark contribute to much shorter deionization intervals, required to quit sparking and evacuate charged particles in order to reinstate the voltage and proceed with the operation. In addition, HF HV power supply provides a significant reduction in size and weight of the complete ESP installation, hence reducing the tons of steel that has to be built in. Therefore, the HF HV power supply may be the key instrument to reducing the cost of the dedusting ecological equipment. Besides, size and weight reduction leads to cost savings of installation and maintenance. According to estimates, savings in steel may reach 30%, contributing to the overall cost savings of roughly 20%. Within this paper, in addition to describing the AR70/1000 unit topology and principles of operation, the paper presents the results and measurements obtained during extensive experimental investigations wherein performances of 50 Hz based thyristor units with T/R sets are compared to HF HV power supply.


2021 ◽  
Vol 1 (73) ◽  
pp. 36-40
Author(s):  
M. Koroli

In the global energy sector, there is a steady trend towards an increase in the production and consumption of energy. As the analysis of the technology has shown, mini-Thermal Power Plants (TPP) are one of the key solutions to the problem. The construction, as well as the reconstruction of existing boiler houses in the mini-TPP will not only ensure more efficient use of fuel through the combined production of electric and thermal energy, but also improve the reliability of power supply to settlements and industrial enterprises


2021 ◽  
Vol 1045 ◽  
pp. 212-225
Author(s):  
Olena Svietkina ◽  
Kostiantyn Bas ◽  
Sergiy Boruk ◽  
Roman Klishchenko ◽  
Oleksandr Yehurnov ◽  
...  

In Ukraine, up to 75% of all electricity is supplied by thermal power plants, the main type of fuel for which is coal, which leads to the release of ash and slag waste at power plants in huge quantities. Every 10 years (according to statistical data) the amount of ash and slag produced at thermal power plants doubles. The use and creation of new modified consumers of coal-water fuel (CWF) and coal-water suspensions (CWS) occurs periodically. The ease of handling suspensions is captivating: in the energy sector, they can serve as the basis for the effective disposal of numerous accumulated wastes from coal preparation and oil refining, a significant reduction in the consumption of minerals for generating heat and electric energy, and minimizing the effect of heat power engineering on public health and the state of nature.


Author(s):  
Stephan Heide ◽  
Christian Felsmann ◽  
Uwe Gampe ◽  
Sven Boje ◽  
Bernd Gericke ◽  
...  

Existing solar thermal power plants are based on steam turbine cycles. While their process temperature is limited, solar gas turbine (GT) systems provide the opportunity to utilize solar heat at a much higher temperature. Therefore there is potential to improve the efficiency of future solar thermal power plants. Solar based heat input to substitute fuel requires specific GT features. Currently the portfolio of available GTs with these features is restricted. Only small capacity research plants are in service or in planning. Process layout and technology studies for high solar share GT systems have been carried out and have already been reported by the authors. While these investigations are based on a commercial 10MW class GT, this paper addresses the parameterization of high solar share GT systems and is not restricted to any type of commercial GT. Three configurations of solar hybrid GT cycles are analyzed. Besides recuperated and simple GT with bottoming Organic Rankine Cycle (ORC), a conventional combined cycle is considered. The study addresses the GT parameterization. Therefore parametric process models are used for simulation. Maximum electrical efficiency and associated optimum compressor pressure ratio πC are derived at design conditions. The pressure losses of the additional solar components of solar hybrid GTs have a different adversely effect on the investigated systems. Further aspects like high ambient temperature, availability of water and influence of compressor pressure level on component design are discussed as well. The present study is part of the R&D project Hybrid High Solar Share Gas Turbine Systems (HYGATE) which is funded by the German Ministry for the Environment, Nature and Nuclear Safety and the Ministry of Economics and Technology.


Author(s):  
Washington Orlando Irrazabal Bohorquez ◽  
Joa˜o Roberto Barbosa ◽  
Luiz Augusto Horta Nogueira ◽  
Electo E. Silva Lora

The operational rules for the electricity markets in Latin America are changing at the same time that the electricity power plants are being subjected to stronger environmental restrictions, fierce competition and free market rules. This is forcing the conventional power plants owners to evaluate the operation of their power plants. Those thermal power plants were built between the 1960’s and the 1990’s. They are old and inefficient, therefore generating expensive electricity and polluting the environment. This study presents the repowering of thermal power plants based on the analysis of three basic concepts: the thermal configuration of the different technological solutions, the costs of the generated electricity and the environmental impact produced by the decrease of the pollutants generated during the electricity production. The case study for the present paper is an Ecuadorian 73 MWe power output steam power plant erected at the end of the 1970’s and has been operating continuously for over 30 years. Six repowering options are studied, focusing the increase of the installed capacity and thermal efficiency on the baseline case. Numerical simulations the seven thermal power plants are evaluated as follows: A. Modified Rankine cycle (73 MWe) with superheating and regeneration, one conventional boiler burning fuel oil and one old steam turbine. B. Fully-fired combined cycle (240 MWe) with two gas turbines burning natural gas, one recuperative boiler and one old steam turbine. C. Fully-fired combined cycle (235 MWe) with one gas turbine burning natural gas, one recuperative boiler and one old steam turbine. D. Fully-fired combined cycle (242 MWe) with one gas turbine burning natural gas, one recuperative boiler and one old steam turbine. The gas turbine has water injection in the combustion chamber. E. Fully-fired combined cycle (242 MWe) with one gas turbine burning natural gas, one recuperative boiler with supplementary burners and one old steam turbine. The gas turbine has steam injection in the combustion chamber. F. Hybrid combined cycle (235 MWe) with one gas turbine burning natural gas, one recuperative boiler with supplementary burners, one old steam boiler burning natural gas and one old steam turbine. G. Hybrid combined cycle (235 MWe) with one gas turbine burning diesel fuel, one recuperative boiler with supplementary burners, one old steam boiler burning fuel oil and one old steam turbine. All the repowering models show higher efficiency when compared with the Rankine cycle [2, 5]. The thermal cycle efficiency is improved from 28% to 50%. The generated electricity costs are reduced to about 50% when the old power plant is converted to a combined cycle one. When a Rankine cycle power plant burning fuel oil is modified to combined cycle burning natural gas, the CO2 specific emissions by kWh are reduced by about 40%. It is concluded that upgrading older thermal power plants is often a cost-effective method for increasing the power output, improving efficiency and reducing emissions [2, 7].


Author(s):  
Igor Pioro ◽  
Mohammed Mahdi ◽  
Roman Popov

SuperCritical Fluids (SCFs) have unique thermophyscial properties and heat-transfer characteristics, which make them very attractive for use in power industry. In this chapter, specifics of thermophysical properties and heat transfer of SCFs such as water, carbon dioxide and helium are considered and discussed. Also, particularities of heat transfer at SuperCritical Pressures (SCPs) are presented, and the most accurate heat-transfer correlations are listed. SuperCritical Water (SCW) is widely used as the working fluid in the SCP Rankine “steam”-turbine cycle in fossil-fuel thermal power plants. This increase in thermal efficiency is possible by application of high-temperature reactors and power cycles. Currently, six concepts of Generation-IV reactors are being developed, with coolant outlet temperatures of 500°C~1000°C. SCFs will be used as coolants (helium in GFRs and VHTRs; and SCW in SCWRs) and/or working fluids in power cycles (helium; mixture of nitrogen (80%) and helium [20%]; nitrogen, and carbon dioxide in Brayton gas-turbine cycles; and SCW “steam” in Rankine cycle).


Sign in / Sign up

Export Citation Format

Share Document