Microscopic evaluation of rotatory and handle caries removal on glass ionomer cement/dentin interface

2018 ◽  
Vol 17 ◽  
pp. 1-9
Author(s):  
Silvio José Mauro ◽  
Adriana Beatriz Silveira Pinto Fernandes ◽  
Fernando Yamamoto Chiba ◽  
Renato Herman Sundfeld ◽  
Suzely Adas Saliba Moimaz ◽  
...  

Aim: This study evaluated the interface between glass ionomer cement (GIC) and dentin using the conventional and atraumatic restorative treatment (ART) techniques for removal of decayed tissue. Materials and Methods: After preparation of the cavities by the conventional (Group I – GI) and ART (Group II – GII) techniques, the specimens were divided into 3 subgroups according to the GIC used (n=10). The conventional GIC KETAC FILL (3M/ESPE) was used in the groups GI-1 and GII-1, the conventional GIC VIDRION R (SS WHITE) in the groups GI-2 and GII-2, and the modified GIC FUJI II LC (GC Corporation) in the groups GI-3 and GII-3. For the microscopic analysis, the teeth were decalcified in a solution containing equal portions of 50% formic acid and 20% sodium citrate, dehydrated and submitted to paraffin baths. The samples were sectioned (6mm in thickness), stained by the Brown and Brenn method, and evaluated in a light microscope. Results: The microscopic analysis revealed interaction between the material and dentin structure only with the FUJI II LC. In addition, the behavior was superior for the conventional technique in comparison to the ART technique. Conclusion: It was concluded that the technique used for carious dentin removal does not seem to be determinant for the bonding of ionomeric materials to the dental structure, except for the resin-modified GIC in which the formed hybrid layer was higher using the conventional technique.

2017 ◽  
Vol 25 (5) ◽  
pp. 541-550 ◽  
Author(s):  
Cristiane Duque ◽  
Kelly Limi Aida ◽  
Jesse Augusto Pereira ◽  
Gláucia Schuindt Teixeira ◽  
Angela Scarparo Caldo-Teixeira ◽  
...  

2016 ◽  
Vol 3 (4) ◽  
pp. 730
Author(s):  
Patricia Aleixo dos Santos Domingos ◽  
Livia Maria Prado Fonseca ◽  
Ana Luisa Botta Martins de Oliveira

AIM: This study aimed to report a case in which the technique used was the atraumatic Restorative Treatment (ART) in patients with fear of conventional treatment. MATERIAL AND METHODS: This procedure consisted in the treatment of carious lesions in the patient associated with the program of educational and preventive measures which the patient has undergone. The technique described here was performed on tooth 85, which presented atypical carious lesion cavity, through the removal of softened carious tissue with the use of hand instruments, without anesthesia and use of direct restorative material with fluoride release (glass ionomer cement). RESULTS: As a result of this technique, there was greater patient cooperation and decrease of anxiety initially revealed. CONCLUSION: Thus, it might be concluded that the Atraumatic Restorative Treatment is a technique already established that showed clinical effectiveness in controlling the evolution of the carious process and that being well indicated, was able to induce more cooperation from the patient, leading to the success of therapy restorer. The conventional glass ionomer cement showed excessive surface wear and therefore should not be used to restore atypical cavities.


2006 ◽  
Vol 20 (2) ◽  
pp. 91-96 ◽  
Author(s):  
Mônica Tostes Amaral ◽  
Antônio Carlos Guedes-Pinto ◽  
Orlando Chevitarese

This work evaluated the remineralization of demineralized enamel of pits and fissures of human third molars sealed with a glass ionomer cement (Fuji IX, GC Corporation - Japan) or with a Bis-GMA sealant (Delton - Dentsply). Ten volunteers participated in this in situ study that consisted of two thirty-day periods using intra-oral devices, with a week’s interval in between. Four experimental treatment procedures and one control were randomly assigned to the volunteers’ specimens: Group I, no treatment, control; Group II, artificial caries process; Group III, same treatment as Group II, but sealed with Delton (Dentsply); Group IV, same treatment as Group II, but sealed with Fuji IX (GC Corporation - Japan); Group V, same treatment as Group II and no sealing. Groups I and II were not submitted to the oral environment and served as controls. After a period of 30 days in the oral environment, the specimens were removed from the devices, embedded in acrylic resin, ground flat and polished. Then, Knoop hardness tests were performed, with a 25 g static load applied for 15 seconds. The measurements were made from the base of the fissure up to an opening of 600 µm, pre-established between the inclines of the cusps. Three indentations were then made, located at 25, 75, and 125 µm in depth from the outer enamel margin and 100 µm apart from each other (Micromet 2003). The Brieger F and Bonferroni’s tests were applied to the measurements. It was concluded that sealing with the glass ionomer cement Fuji IX was capable of making the enamel of pits and fissures more resistant by increasing the value of Knoop hardness.


2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


2020 ◽  
Vol 23 (1) ◽  
Author(s):  
Radwa Hamdy Aboelenen ◽  
Ashraf Mokhtar ◽  
Hanaa Zaghloul

Objective: To evaluate the marginal fit and microleakage of monolithic zirconia crowns cemented with bioactive cement (Ceramir) compared to that cemented with glass ionomer cement and to evaluate the effect of thermocycling on marginal fit. Materials and methods: Twenty sound human molar teeth were prepared to receive a monolithic zirconia crowns. Teeth were divided randomly into two equal groups according to the type of luting cement. Group I: glass ionomer cement and group II: Ceramir cement. After cementation, the vertical marginal gap was assessed by using stereomicroscope before and after thermocycling. Twenty equidistant measurement points were taken for each crown. Leakage assessment was carried out using Fuchsin dye penetration followed by digital photography under a stereomicroscope. Data were analyzed by Mann-Whitney U test to compare between the two luting cements. Wilcoxon signed-rank test was used to evaluate the effect of thermocycling on the marginal fit (P ≤ 0.05)
Results: Whether before or after thermocycling, the results showed no significant difference between the marginal gap values of the two tested groups. For both groups, there was a significant increase in marginal gap values after thermocycling. Also, there was no significant difference between leakage scores of the two tested groups. Conclusions: Similarity in the physical properties and chemical composition of the two cements result in a non- significant effect on the vertical marginal fit and the extent of microleakage of translucent zirconia crowns.  Thermocycling had a negative impact on the vertical marginal gap of the two tested luting agents.


2020 ◽  
pp. 168-172

The occurrence of external cervical root resorption (ECRR) is rare. Herein, we report a case of extensive ECRR in the coronal third of the distal root of a mandibular right molar with food impaction and periapical radiolucency. The distal root was perforated and damaged due to delayed treatment. The resorptive defect was debrided, and the defect was restored with conventionally setting restorative glass-ionomer cement. Postoperative follow-up revealed complete healing.


2018 ◽  
Vol 14 (1) ◽  
pp. 24
Author(s):  
Dr. Sazan Sherdil Saleem

The present study was aimed to evaluate and compare the compressive strength ofconventional glass ionomer cement with resin modified glass ionomer, compomer andmicrohybrid composite. A total of 40 specimens of esthetic restorative materials werefabricated using customized cylindrical teflon mould measuring 6mm height and 4mmdiameter and were grouped with ten specimens in each group, Group I: Conventionalglass ionomer cement (Fuji II). Group II: Resin modified glass ionomer (Fuji II LC).Group III: Compomer (Dyract AP) and Group IV: Microhybrid composite resin(Tetric Ceram).They were covered with Mylar strip and were cured using LED lightcuring unit. Compressive strength was evaluated using Universal testing machine. Theresult showed that there were a significant difference among the groups in whichTetric Ceram showed highest compressive strength and Fuji II showed the leastcompressive strength


Sign in / Sign up

Export Citation Format

Share Document