scholarly journals Reactive power control

Author(s):  
Vasyl Kalinchyk ◽  
Vitaliy Pobigaylo ◽  
Vitaliy Kalinchyk ◽  
Viktor Skosyrev

The article investigates the methods of control of reactive power modes. It is shown that ensuring the efficiency of electricity transmission and distribution is inseparable from setting and solving problems related to reducing electricity losses in networks. Moreover, one of the most effective ways to reduce electricity losses, as well as improve its quality at the terminals of electrical receivers is to compensate for reactive power, which is carried out using various compensating devices. It is shown that the control of the reactive power mode is carried out in accordance with the Methodology for calculating the fee for the flow of reactive energy between the power transmission organization and its consumers. It is shown that the indicator of economically advantageous value of the level of reactive energy consumption can be cos φз, the value of which is predetermined. The procedure for controlling the reactive power mode contains two main stages: the stage of determining the magnitude of the possible reduction of the current cos φ above the set and the stage of determining and implementing control effects aimed at eliminating possible deviations. Preferably, it is preferable to focus on those methods that are based on the study of forecast estimates, which constitute the source information for management decisions. It is expedient to use adaptive methods of exponential smoothing as a basis for operative forecasting of electric loading. Reactive power mode is controlled by compensating units. It is shown that the control of voltage modes in the power supply system significantly affects the modes of reactive power consumption. In this regard, it is advisable to comprehensively solve the problem of reactive power control both by controlling the compensating units and the impact on the voltage regimes of the power supply system. In the calculation model, the reactive load of the distribution network is given by its static characteristics, which can be the basis for regulating the reactive load. To implement regulation in the power supply centers of electrical networks, technical means are provided on the basis of changing the transformation coefficient or generating reactive power by counter-voltage regulation.

Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3437 ◽  
Author(s):  
Dario Garozzo ◽  
Giuseppe Marco Tina

The increasing presence of distributed generation (DG) in the electrical grid determines new challenges in grid operations, especially in terms of voltage and frequency regulation. Recently, several grid codes have required photovoltaic (PV) inverters to control their reactive power output in order to provide voltage regulation services, and the allocation of a certain amount of active power reserve for fast frequency response (FFR) service during under-frequency contingencies is needed. This requirement involves a significant waste of energy for PV systems, due to the necessity to constantly operate in de-loaded mode, under normal operating conditions. In addition, the variability of the irradiance can affect the correct amount of active power reserve that the system can provide in the moments after an under-frequency occurrence. The increasing number of battery energy storage systems (BESSs), coupled to PV systems, can be used to provide a worthy contribution to this frequency regulation service. The aim of this paper is to analyze the efficiency of active power reserve provided by a BESS connected to the DC bus of a non-ideal grid-connected PV inverter, taking into account the impact of reactive power control. For this purpose, the contribution of BESSs to frequency regulation is discussed and, starting from an existing model of real inverter, an analytical formulation for active power reserve evaluation is presented. Results concerning the impact of reactive power control are also given. Finally, the possibility for a low voltage (LV) grid with aggregated PV systems and BESSs to contribute to grid active power reserve is considered. Different voltage control strategies are compared, defining a helpful new parameter.


2021 ◽  
pp. 1-1
Author(s):  
Jiakang Yang ◽  
Wayes Tushar ◽  
Tapan K. Saha ◽  
Mollah R. Alam ◽  
Yong Li

2017 ◽  
Vol 201 (1) ◽  
pp. 38-56 ◽  
Author(s):  
KOUICHIRO KOUNO ◽  
EIJI NAKANISHI ◽  
YOSHIAKI NAGANO ◽  
MASAHIDE HOJO

2022 ◽  
Vol 1 (15) ◽  
pp. 22-28
Author(s):  
Igor' Golovanov ◽  
Alena Alekseeva ◽  
Vladimir Proskuryakov ◽  
Roman Samchuk

Electrical circuits of reactive power compensation on the basis of thyristor control circuits in the power supply system of oil refineries are considered. The main advantages, advantages over traditional reactive power compensation systems and directions of introduction into the power supply system of modern production are formulated.


2020 ◽  
Vol 2 (58) ◽  
pp. 28-32
Author(s):  
A. Gapon ◽  
O. Grib ◽  
S. Kozlov ◽  
O. Yevseienko ◽  
O. Levon

The work is devoted to solving an urgent problem - the development of a computer model of the energy consumption system of the Institute of the ionosphere of the National Academy of Sciences and the Ministry of Education and Science of Ukraine in order to solve the problem of increasing the energy efficiency of the measuring complex. The power supply system of the complex is described, a generalized structural diagram of the loads - powerful consumers of electricity is presented. The graphs characterizing the energy consumption of individual powerful loads are presented, the problem of compensating the reactive power of loads is shown. The adequacy of the developed model is confirmed by the coincidence of the shape and values of the experimentally obtained characteristics on loads with the characteristics of the model. The model adequacy was assessed by the variance of feedback deviations from the system mean. The results obtained confirmed the possibility of using the developed Matlab-model of the energy consumption system of the measuring complex for creating and testing on the model of an energy-efficient power supply system, which will ensure the stable operation of scientific equipment for the implementation of research programs of the NAS of Ukraine.


2013 ◽  
Vol 321-324 ◽  
pp. 1414-1417 ◽  
Author(s):  
Jing Chen ◽  
Qi Jian Cheng ◽  
You Xin Yuan ◽  
Wei Yang

The objective of this work is to research on a SVC auto-compensation method to improve the power factor of the power supply system. Firstly, the principles of the reactive power compensation of FC+TCR are analyzed qualitatively. According to the deficiencies of this compensator, a novel SVC auto-compensating method based on the variable reactor is presented. The reactor controlled by anti-parallel thyristors is namely as the variable reactor in this method. The secondary-side equivalent inductance of the variable reactor is varied by adjusting the SCR firing angles. And then, the equivalent inductance of the variable reactor of the compensator branch is adjusted indirectly for compensating the corresponding reactive power after the working conditions of the load are changed. Therefore, the auto-compensating of this var compensator is realized. The auto-compensating principles of this compensator have been analyzed, and a research on the compensating parameters of this compensator is given emphatically in this paper. Finally, the essential operation steps of this SVC compensation method are given. The research of this paper has laid a theoretical foundation for this compensator in industrial applications.


Author(s):  
Georgios C. Kryonidis ◽  
Kyriaki-Nefeli D Malamaki ◽  
Spyros I. Gkavanoudis ◽  
Konstantinos Oureilidis ◽  
Eleftherios O Kontis ◽  
...  

Author(s):  
Oleg Arsent'ev ◽  
Evgeniy Krylov

the questions of the organization of power supply system with control elements to reduce the impact of peak loads on the operation of electrical equipment and reduce energy costs


Sign in / Sign up

Export Citation Format

Share Document