scholarly journals Pressure gauge calibration applying 0-A-0 pressurization to reference gauge

ACTA IMEKO ◽  
2016 ◽  
Vol 5 (1) ◽  
pp. 59 ◽  
Author(s):  
Hiroaki Kajikawa ◽  
Tokihiko Kobata

<p>A calibration method is proposed to improve pressure calibration that uses a pressure gauge as the reference device. The reference gauge is pressurized by a 0-A-0 pressurization procedure, whereas the test gauge can be pressurized through various procedures. The calibration results with this method were consistent with those calibrated against a pressure balance. The method is expected to help develop low-cost pressure calibration systems that are more precise.</p>

2015 ◽  
Vol 2015 ◽  
pp. 1-18 ◽  
Author(s):  
Heikki Hyyti ◽  
Arto Visala

An attitude estimation algorithm is developed using an adaptive extended Kalman filter for low-cost microelectromechanical-system (MEMS) triaxial accelerometers and gyroscopes, that is, inertial measurement units (IMUs). Although these MEMS sensors are relatively cheap, they give more inaccurate measurements than conventional high-quality gyroscopes and accelerometers. To be able to use these low-cost MEMS sensors with precision in all situations, a novel attitude estimation algorithm is proposed for fusing triaxial gyroscope and accelerometer measurements. An extended Kalman filter is implemented to estimate attitude in direction cosine matrix (DCM) formation and to calibrate gyroscope biases online. We use a variable measurement covariance for acceleration measurements to ensure robustness against temporary nongravitational accelerations, which usually induce errors when estimating attitude with ordinary algorithms. The proposed algorithm enables accurate gyroscope online calibration by using only a triaxial gyroscope and accelerometer. It outperforms comparable state-of-the-art algorithms in those cases when there are either biases in the gyroscope measurements or large temporary nongravitational accelerations present. A low-cost, temperature-based calibration method is also discussed for initially calibrating gyroscope and acceleration sensors. An open source implementation of the algorithm is also available.


Author(s):  
Zhong Zhao ◽  
Rong Ma ◽  
Weiguo Zhang

Abstract An intelligent gyro drift calibration method for low-cost inertial system is presented in this paper. This method based on fuzzy reasoning and dynamic estimation can calibrate time-varying gyro drift in the motion of vehicle. Experiments have been done on three strapdown inertial all-attitude systems constituted of piezoelectric rate gyros. The result shows that this method is effective by which the residual of piezoelectric gyro drift can be reduced to about one percent of its original drift value.


Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4157 ◽  
Author(s):  
Dafeng Long ◽  
Xiaoming Zhang ◽  
Xiaohui Wei ◽  
Zhongliang Luo ◽  
Jianzhong Cao

Attitude measurement is an essential technology in projectile trajectory correction. Magnetometers have been used for projectile attitude measurement systems as they are small in size, lightweight, and low cost. However, magnetometers are seriously disturbed by the artillery magnetic field during launch. Moreover, the error parameters of the magnetometers, which are calibrated in advance, usually change after extended storage. The changed parameters have negative effects on attitude estimation of the projectile. To improve the accuracy of attitude estimation, the magnetometers should be calibrated again before launch or during flight. This paper presents a fast calibration method specific for a spinning projectile. At the launch site, the tri-axial magnetometer is calibrated, the parameters of magnetometer are quickly obtained by optimal ellipsoid fitting based on a least squares criterion. Then, the calibration parameters are used to compensate for magnetometer outputs during flight. The numerical simulation results show that the proposed calibration method can effectively determine zero bias, scale factors, and alignment angle errors. Finally, a semi-physical experimental system was designed to further verify the performance of the calibration method. The results show that pitch angle error reduces from 3.52° to 0.58° after calibration. The roll angle error is reduced from 2.59° to 0.65°. Simulations and experimental results indicate that the accuracy of magnetometer in strap-down spinning projectile has been greatly enhanced, and the attitude estimation errors are reduced after calibration.


2020 ◽  
Vol 4 (2) ◽  
pp. 1-4
Author(s):  
Niko Murrell ◽  
Ryan Bradley ◽  
Nikhil Bajaj ◽  
Julie Whitney ◽  
George T.-C. Chiu

2020 ◽  
Vol 12 (9) ◽  
pp. 1393 ◽  
Author(s):  
Andreas Krietemeyer ◽  
Hans van der Marel ◽  
Nick van de Giesen ◽  
Marie-Claire ten Veldhuis

The recent release of consumer-grade dual-frequency receivers sparked scientific interest into use of these cost-efficient devices for high precision positioning and tropospheric delay estimations. Previous analyses with low-cost single-frequency receivers showed promising results for the estimation of Zenith Tropospheric Delays (ZTDs). However, their application is limited by the need to account for the ionospheric delay. In this paper we investigate the potential of a low-cost dual-frequency receiver (U-blox ZED-F9P) in combination with a range of different quality antennas. We show that the receiver itself is very well capable of achieving high-quality ZTD estimations. The limiting factor is the quality of the receiving antenna. To improve the applicability of mass-market antennas, a relative antenna calibration is performed, and new absolute Antenna Exchange Format (ANTEX) entries are created using a geodetic antenna as base. The performance of ZTD estimation with the tested antennas is evaluated, with and without antenna Phase Center Variation (PCV) corrections, using Precise Point Positioning (PPP). Without applying PCVs for the low-cost antennas, the Root Mean Square Errors (RMSE) of the estimated ZTDs are between 15 mm and 24 mm. Using the newly generated PCVs, the RMSE is reduced significantly to about 4 mm, a level that is excellent for meteorological applications. The standard U-blox ANN-MB-00 patch antenna, with a circular ground plane, after correcting the phase pattern yields comparable results (0.47 mm bias and 4.02 mm RMSE) to those from geodetic quality antennas, providing an all-round low-cost solution. The relative antenna calibration method presented in this paper opens the way for wide-spread application of low-cost receiver and antennas.


Sign in / Sign up

Export Citation Format

Share Document