scholarly journals Elevated d-dimer cut-off values for computed tomography pulmonary angiography—d-dimer correlates with location of embolism

2016 ◽  
Vol 4 (11) ◽  
pp. 212-212 ◽  
Author(s):  
Mateuzs Piotr Kubak ◽  
Peter Mæhre Lauritzen ◽  
Arne Borthne ◽  
Espen Asak Ruud ◽  
Haseem Ashraf
2020 ◽  
pp. 33-34
Author(s):  
Mantavya Patel ◽  
Sanjay Paliwal ◽  
Rachit Saxena

Introduction: Early diagnosis of pulmonary embolism can reduce morbidity and motility. D-dimer is well known parameter having high negative prediction value. This study focused on role of D-dimer in early prediction of presence and severity of pulmonary embolism. Material and Methods: Thirty patients with clinical suspicion of pulmonary embolism along with high D-dimer value were included in this study. All selected patients underwent computed tomography pulmonary angiography assessment. D-dimer value was correlated with presence and proximity of pulmonary embolism. Results: Out of thirty selected patients 50% had pulmonary embolism on computed tomography pulmonary angiography assessment. D-dimer value correlated well with presence and proximity of pulmonary embolism. Conclusion: D-dimer value more than 4000 ng/ml had high positive prediction value (79%) in suspected clinical cases. Value more than 8000 ng/ml further improve value to nearly 100% in suspected cases.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Engin Ozakin ◽  
Filiz Baloglu Kaya ◽  
Nurdan Acar ◽  
Arif Alper Cevik

Introduction.The purpose of this study is to analyze the frequency of other diagnoses and findings in patients that were diagnosed with or not diagnosed with PE following the CTPA in the ED and to analyze the relationship between diagnosis and D-dimer.Instrument and Method.This study involves all patients that presented to the ED that underwent CTPA with the prediagnosis of PE. The items considered in this study were their reason for presenting to the ED and pretest clinical risks for PE, D-dimer, and CTPA results.Findings.Of the 696 cases, the most common cause was shortness of breath (59.3%). The CTPA showed that 145 (20.83%) patients were suffering from PE. Among the remaining cases, 464 (66.66%) patients had pathological findings other than PE and 87 (12.5%) patients were reported as normal. The most common pathological results other than PE found in CTPA were atelectasis in 244 (39.9%) and ground glass in 165 (23.7%), as well as nonpulmonary results in 70 (10.05%) patients. The differences in D-dimer results of patients diagnosed with PE, patients diagnosed with another pathology, and patients with normal CTPA results were statistically significant (P<0.001).Conclusion.CTPA scanning, performed on the basis of assessment scoring, helps in discovering other fatal pathologies in addition to PE.


CJEM ◽  
2020 ◽  
Vol 22 (S1) ◽  
pp. S78-S78
Author(s):  
L. Salehi ◽  
P. Phalpher ◽  
H. Yu ◽  
M. Ossip ◽  
R. Valani ◽  
...  

Introduction: As the availability of Computed Tomography Pulmonary Angiography (CTPA) to rule out pulmonary embolism (PE) increases, so too does its utilization, and consequent overutilization. A variety of evidence-based algorithms and decision rules using clinical criteria and D-Dimer testing have been proposed as instruments to allow physicians to safely rule out a PE in low-risk patients. However, studies have shown mixed results with respect to both physician uptake of these decision rules and their impact on improving ordering practices among physicians. The objective of this study is to describe the prevalence of D-Dimer utilization among ED physicians and its impact on positive yield rates of CTPAs in a community setting. Methods: Data was collected on all CTPA studies ordered by ED physicians at two very high-volume community hospitals and an affiliated urgent care centre during the 2-year period between January 1, 2016 and December 31, 2017. For each CTPA, we determined if 1) a D-Dimer had been ordered prior to CTPA, if 2) the D-Dimer was positive, and if 3) the CTPA was positive for a PE. Using a chi-square test, we compared the diagnostic yield for those patients who had a D-Dimer prior to their CTPA and those who did not. Results: A total of 2,811 CTPAs were included in the analysis. Of these, 964 CTPAs (34.3%) were ordered without a D-Dimer. Of those 1,847 patients who underwent D-Dimer testing prior to the CTPA, 343 (18.7%) underwent a CTPA despite a negative D-Dimer. When compared as a group, those CTPAs preceded by a D-Dimer showed no significant difference in positive yields when compared to those CTPAs ordered without a prior D-Dimer (9.9% versus 11.3%, p = 0.26). Conclusion: The findings of this study present a complicated picture of the impact of D-Dimer utilization on CTPA ordering patterns. There is evidence of suboptimal uptake of routine D-Dimer ordering, and adherence to guidelines in terms of forgoing CTPAs in low-risk patients with negative D-Dimers. While this study design leaves unanswered the question of how many CTPAs were avoided as a result of a negative D-Dimer, the finding of a similar positive yield among those patients who had a D-Dimer ordered versus those who did not is interesting, and illustrative of the issues arising from the high false-positive rates associated with D-Dimer screening.


2021 ◽  
Author(s):  
Eda Çelik ◽  
Ömer Araz ◽  
Buğra Kerget ◽  
Elif Yılmazel Uçar ◽  
Metin Akgün ◽  
...  

Abstract Purpose: Acute pulmonary thromboembolism (PTE) is an important cause of morbidity and mortality that can reduce quality of life due to long-term complications during and after treatment discontinuation. The aim of this study was to evaluate patients for these complications before discontinuing treatment and determine the necessity of computed tomography pulmonary angiography (CTPA) imaging.Methods: This retrospective study included 116 patients over the age of 18 who received anticoagulant treatment for at least 3 months and presented for treatment discontinuation to the Atatürk University Research Hospital Chest Diseases Outpatient Clinic between January 2015 and September 2019. Results: CTPA performed at treatment discontinuation showed complete thrombus resolution with treatment in 73 patients (62.9%). High pulmonary artery obstruction index (PAOI) at diagnosis was statistically associated with findings of residual or chronic thrombus on CTPA at treatment discontinuation (p=0.001). In the differentiation of patients with residual/chronic thrombus and those with thrombus resolution, D-dimer at a cut-off value of 474 µg/L had 60% sensitivity and 70% specificity. At a cut-off value of 35.5 mmHg, mean pulmonary artery pressure on echocardiography had sensitivity and specificity of 72% and 77%, respectively. At a cut-off of 23.75, PAOI had sensitivity and specificity of 93% and 69%, respectively.Discussion: In addition to physical examination findings, D-dimer and echocardiography were guiding parameters in the evaluation of treatment discontinuation and thrombus resolution in patients presenting to the outpatient clinic for discontinuation of treatment for acute PTE. PAOI at diagnosis may be another important guiding parameter in addition to these examinations.


2021 ◽  
Vol 71 (6) ◽  
pp. 1962-66
Author(s):  
Uzma Nisar ◽  
Hina Nasir ◽  
Atiq Ur Rehman Slehria ◽  
Abdur Rahim Rahim Palwa ◽  
Rashid Hussain ◽  
...  

Objective: To compare the effectiveness of plasma D-dimer levels with findings of 128-slice spiral computed tomography pulmonary angiography (CTPA) in patients with clinical suspicion of pulmonary embolism. Study Design: Retrospective observational study Place and Duration of Study: Department of Computed Tomography, Armed Forces Institute of Radiology & Imaging, Pak Emirates Military Hospital Rawalpindi, from Jan 2018 to Dec 2018. Methodology: A total of 59 patients were inducted who presented in Emergency Department, Pak Emirates Military Hospital Rawalpindi with clinical suspicion of Pulmonary Embolism. The main symptoms were shortness of breath and chest pain. Plasma D-dimer levels of all patients were sent to laboratory and CTPA was performed at Computed Tomography department, Armed Forces Institute of Radiology & Imaging using 128-slice spiral computed tomography. Results: 36 patients (61%) were males and 23 (39%) were females with an average age of 48.03 ± 18.06 years (range 23-85 years). Out of 59 patients, D-dimer levels were raised in 28 cases (47.4%) while 31 patients (52.6%) showed normal levels. Pulmonary Embolism was detected by CTPA in 30 cases (50.8%) while 29 patients (49.2%) were without obvious abnormality. Conclusion: Plasma D-Dimer levels show low sensitivity, specificity and negative predictive value and cannot exclude Pulmonary Embolism without CTPA. Computed Tomography Pulmonary Angiography (CTPA) remains diagnostic modality of choice for definitive assessment of Pulmonary Embolism in patients reporting at the emergency reception.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Leila Salehi ◽  
Prashant Phalpher ◽  
Hubert Yu ◽  
Jeffrey Jaskolka ◽  
Marc Ossip ◽  
...  

Abstract Background A variety of evidence-based algorithms and decision rules using D-Dimer testing have been proposed as instruments to allow physicians to safely rule out a pulmonary embolism (PE) in low-risk patients. Objective To describe the prevalence of D-Dimer utilization among emergency department (ED) physicians and its impact on positive yields and utilization rates of Computed Tomography Pulmonary Angiography (CTPA). Methods Data was collected on all CTPA studies ordered by ED physicians at three sites during a 2-year period. Using a chi-square test, we compared the diagnostic yield for those patients who had a D-Dimer prior to their CTPA and those who did not. Secondary analysis was done to examine the impact of D-Dimer testing prior to CTPA on individual physician diagnostic yield or utilization rate. Results A total of 2811 CTPAs were included in the analysis. Of these, 964 CTPAs (34.3%) were ordered without a D-Dimer, and 343 (18.7%) underwent a CTPA despite a negative D-Dimer. Those CTPAs preceded by a D-Dimer showed no significant difference in positive yields when compared to those ordered without a D-Dimer (9.9% versus 11.3%, p = 0.26). At the individual physician level, no statistically significant relationship was found between D-Dimer utilization and CTPA utilization rate or diagnostic yield. Conclusion This study provides evidence of suboptimal adherence to guidelines in terms of D-Dimer screening prior to CTPA, and forgoing CTPAs in patients with negative D-Dimers. However, the lack of a positive impact of D-Dimer testing on either CTPA diagnostic yield or utilization rate is indicative of issues relating to the high false-positive rates associated with D-Dimer screening.


Author(s):  
Alessandra Mirabile ◽  
Nicola Maria Lucarelli ◽  
Enza Pia Sollazzo ◽  
Amato Antonio Stabile Ianora ◽  
Angela Sardaro ◽  
...  

Abstract Purpose To assess the percentage of computed tomography pulmonary angiography (CTPA) procedures that could have been avoided by methodical application of the Revised Geneva Score (RGS) coupled with age-adjusted D-dimer cut-offs rather than only clinical judgment in Emergency Department patients with suspected pulmonary embolism (PE). Material and methods Between November 2019 and May 2020, 437 patients with suspected PE based on symptoms and D-dimer test were included in this study. All patients underwent to CTPA. For each patient, we retrospectively calculated the age-adjusted D-dimer cut-offs and the RGS in the original version. Finally, CT images were retrospectively reviewed, and the presence of PE was recorded. Results In total, 43 (9.84%) CTPA could have been avoided by use of RGS coupled with age-adjusted D-dimer cut-offs. Prevalence of PE was 14.87%. From the analysis of 43 inappropriate CTPA, 24 (55.81%) of patients did not show any thoracic signs, two (4.65%) of patients had PE, and the remaining patients had alternative thoracic findings. Conclusion The study showed good prevalence of PE diagnoses in our department using only physician assessment, although 9.84% CTPA could have been avoided by methodical application of RGS coupled with age-adjusted D-dimer cut-offs.


Sign in / Sign up

Export Citation Format

Share Document