Using Fusulinids to Evaluate the Periodicity of Cycles in a Sequence Stratigraphic Section of Pennsylvanian–Permian Strata and to Suggest Possible Support for low-Frequency Milankovitch Perturbations: Casper Formation, Southeastern Wyoming, U.S.A.

Author(s):  
DIANE M. BURNS ◽  
MERLYND K. NESTELL
Geophysics ◽  
2007 ◽  
Vol 72 (5) ◽  
pp. SM273-SM280 ◽  
Author(s):  
Ståle Johansen ◽  
Espen Granberg ◽  
Donatella Mellere ◽  
Børge Arntsen ◽  
Torben Olsen

In sequence stratigraphic interpretations, the key premise is that stratal surfaces effectively represent geologic timelines. When applied to seismic sections, the fundamental assumption is that primary reflections generally mimic stratigraphic timelines. The main objective of this study was to test how well key reflectors in a seismic section couple to timelines. To achieve the high level of ground control needed for such testing, we combined photogrammetry and traditional sedimentologic fieldwork to optimize the geologic model. We relied further on petrophysical analysis to derive a numerical model suitable for the simulation of seismic data. In spite of laterally discontinuous vertical-impedance contrasts (VICs), false seismic continuity was created, and we observed frequent decoupling of seismic reflectors and stratigraphic timelines. These observations demonstrate how the low-frequency seismic method fails to image normal complexity in a stratigraphic unit. A seismic correlation test showed that the interpreters made numerous mistakes and that such mistakes are very difficult to avoid. The failure of a fundamental assumption, as illustrated here, creates serious problems for the sequence stratigraphic concept when applied to detailed correlation analysis on seismic sections.


2014 ◽  
Vol 152 (5) ◽  
pp. 788-801 ◽  
Author(s):  
BRENT WILSON ◽  
LEE-ANN C. HAYEK

AbstractThe lower bathyal Ocean Drilling Program Hole 1261A was sampled near an upper Quaternary oxygen minimum zone (OMZ). Glauconite, the percentage of the foraminiferal assemblage as benthic specimens and assemblage composition were used to investigate the behaviour of the OMZ. Benthic foraminifera and glauconite were comparable with the upper margin of the modern OMZ off California. The percentage abundances of U. peregrina and C. laevigata were on the Demerara Rise negatively correlated, the proportional abundance of U. peregrina increasing upwards through the section. This reflects variations in proximity to the upper margin of the OMZ. This might reflect either crustal subsidence or long-term shallowing of the OMZ during the earlier late Quaternary. Neither hypothesis can be accepted unequivocally. The purported subsidence can be ascribed to crustal loading by the Amazon and Orinoco deep-sea fans, but this would require that the palaeodepth to the top of the OMZ remains constant across several glacial–interglacial cycles. In contrast, it is difficult to envisage any mechanism that could have caused progressive shallowing of the OMZ across several glacial–interglacial cycles. The epifaunal Planulina wuellerstorfi is related to more oxic waters and enhanced current action. This suggests that intervals with more abundant P. wuellerstorfi were somewhat less dysoxic than those with few. These intervals approximate to those with more abundant C. laevigata. Superimposed on this low-frequency signal is a higher-frequency signal, indicated by a between-sample assemblage turnover index (ATIs) that might prove useful for long-range sequence stratigraphic correlation at bathyal depths.


Author(s):  
K. Hama

The lateral line organs of the sea eel consist of canal and pit organs which are different in function. The former is a low frequency vibration detector whereas the latter functions as an ion receptor as well as a mechano receptor.The fine structure of the sensory epithelia of both organs were studied by means of ordinary transmission electron microscope, high voltage electron microscope and of surface scanning electron microscope.The sensory cells of the canal organ are polarized in front-caudal direction and those of the pit organ are polarized in dorso-ventral direction. The sensory epithelia of both organs have thinner surface coats compared to the surrounding ordinary epithelial cells, which have very thick fuzzy coatings on the apical surface.


Author(s):  
Robert E. Nordquist ◽  
J. Hill Anglin ◽  
Michael P. Lerner

A human breast carcinoma cell line (BOT-2) was derived from an infiltrating duct carcinoma (1). These cells were shown to have antigens that selectively bound antibodies from breast cancer patient sera (2). Furthermore, these tumor specific antigens could be removed from the living cells by low frequency sonication and have been partially characterized (3). These proteins have been shown to be around 100,000 MW and contain approximately 6% hexose and hexosamines. However, only the hexosamines appear to be available for lectin binding. This study was designed to use Concanavalin A (Con A) and Ricinus Communis (Ricin) agglutinin for the topagraphical localization of D-mannopyranosyl or glucopyranosyl and D-galactopyranosyl or DN- acetyl glactopyranosyl configurations on BOT-2 cell surfaces.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


Sign in / Sign up

Export Citation Format

Share Document