scholarly journals Determination of Rubidium by ID-ICP-QMS/QMS with Fluoromethane as the Reaction Cell Gas to Separate Spectral Interference from Strontium

2018 ◽  
Vol 34 (6) ◽  
pp. 681-685 ◽  
Author(s):  
Yanbei ZHU ◽  
Kazumi NAKANO ◽  
Yasuyuki SHIKAMORI
Author(s):  
Pratik S Mehta ◽  
Pratik R. Patel ◽  
Rajesh R Parmar ◽  
M M K Modasiya ◽  
Dushyant A Shah

A novel, simple, accurate, sensitive, precise and economical derivative spectroscopic method was developed and validated for the determination of cefadroxil and probenecid in synthetic mixture. First order derivative spectroscopy method was adopted to eliminate spectral interference. The method obeys Beer’s Law in concentration ranges of 4-36 μg/ml for cefadroxil and of 5-25 μg/ml of probenecid. The zero crossing point for cefadroxil and probenecid was 260 nm and 237.8 nm respectively in 0.1N HCl. The method was validated in terms of accuracy, precision, linearity, limits of detection, limits of quantitation. This method has been successively applied to synthetic mixture and no interference from the synthetic mixture’s excipients was found.   


1972 ◽  
Vol 26 (1) ◽  
pp. 96-99 ◽  
Author(s):  
Mary Jo Calhoun ◽  
Edward S. DellaMonica

A method for the determination of individual components of complex mixtures is presented. The technique used is based on ir-absorbance measurements for stearic acid at 1700 and at 935 cm−1 when the concentration range exceeds 0.50% wt/vol; for isopropenyl stearate at 1145 and at 865 cm−1; for stearic anhydride at 1030 cm−1 and mixed stearic-acetic anhydride at 1000 cm−1. The baseline method was used in all absorbance measurements. Absorbance-concentration relationships obeyed Beer's law from 0 to 2.0% wt/vol for most compounds; the exception being stearic acid (at 1700 cm−1), where linearity was limited to a maximum 0.50% wt/vol. Due to spectral interference between the two anhydrides at low concentration ratios, an empirical percent transmission ratio method was used to estimate the relative concentration of each. Binary and ternary systems were studied and the standard deviations of the differences between theoretical and calculated values indicate that this method is reliable.


2006 ◽  
Vol 917 ◽  
Author(s):  
Shilpa Dubey ◽  
Keijing Li ◽  
Harish Bhandari ◽  
Zheng Hu ◽  
C. Heath Turner ◽  
...  

AbstractHafnium oxide ultra thin films on Si (100) are being developed to replace thermally grown SiO2 gates in CMOS devices. In this work, a specially designed Attenuated Total Reflectance - Fourier Transform Infra Red Spectroscopy (ATR-FTIR) reaction cell has been developed to observe chemisorption of hafnium (IV) t-butoxide onto a Si and Ge ATR crystal heated up to 250°C and under 1 torr of vacuum to observe the initial reaction pathways and species on the substrate surface in real time and under typical process conditions. Chemisorption spectra were compared to spectra of the liquid precursor and to spectra generated by density functional theory (DFT) calculations of liquid, monodentate and bidentate absorbed precursor. An asymmetric stretching mode located at ~1017 cm-1 present in the chemisorbed spectra but not in the liquid spectra indicates that the adsorbed hafnium containing group is prevalent as a bidentate ligand according to calculations. Surface concentration of the chemisorbed species was dependant on the substrate temperature and precursor partial pressure allowing for determination of heats of adsorption which was 26.5 kJ/mol on Si.


2020 ◽  
Vol 35 (3) ◽  
pp. 626-631 ◽  
Author(s):  
Qingzhou Li ◽  
Wen Zhang ◽  
Zhiyang Tang ◽  
Ran Zhou ◽  
Jiujiang Yan ◽  
...  

LIBS-LIF technology is proposed to enhance the spectral intensity of uranium in ores and eliminate spectral interference to achieve the purpose of improving detection sensitivity.


Sign in / Sign up

Export Citation Format

Share Document